UV light-emitting diode-induced fluorescence detection combined with online sample concentration techniques for capillary electrophoresis

被引:16
作者
Chang, YS [1 ]
Shih, CM [1 ]
Lin, CH [1 ]
机构
[1] Natl Taiwan Normal Univ, Dept Chem, Taipei, Taiwan
关键词
D O I
10.2116/analsci.22.235
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of an ultraviolet (UV) light-emitting diode (LED) to on-line sample concentration/fluorescence detection in capillary electrophoresis (CE) is described. The utility of a UV-LED (peak emission wavelength at 380 nm, similar to 2 mW) for fluorescence detection was demonstrated by examining both a naturally fluorescent (riboflavin) compound and a nonfluorescent compound (tryptophan), respectively. The detection limit for riboflavin was determined to be 0.2 ppm by the normal MEKC mode, which was improved to 3 - 7 ppb when dynamic pH-junction technique was applied. On the other hand, the detection limit of the tryptophan derivative was determined to be 1.5 ppm using the MEKC mode, which was improved to 3 ppb when the sweeping-MEKC mode was applied. In an analysis of an actual sample, the concentrations of riboflavin in beer, and tryptophan in urine and milk samples were determined, respectively.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 33 条
[21]   Sweeping of neutral analytes in electrokinetic chromatography with high-salt-containing matrixes [J].
Quirino, JP ;
Terabe, S ;
Bocek, P .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1934-1940
[22]   Approaching a million-fold sensitivity increase in capillary electrophoresis with direct ultraviolet detection: Cation-selective exhaustive injection and sweeping [J].
Quirino, JP ;
Terabe, S .
ANALYTICAL CHEMISTRY, 2000, 72 (05) :1023-1030
[23]   Sweeping of analyte zones in electrokinetic chromatography [J].
Quirino, JP ;
Terabe, S .
ANALYTICAL CHEMISTRY, 1999, 71 (08) :1638-1644
[24]   Exceeding 5000-fold concentration of dilute analytes in micellar electrokinetic chromatography [J].
Quirino, JP ;
Terabe, S .
SCIENCE, 1998, 282 (5388) :465-468
[25]   Visible diode laser-induced fluorescence detection of phenylacetic acid in plasma derivatized with nile blue and using precolumn phase transfer catalysis [J].
Rahavendran, SV ;
Karnes, HT .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :3022-3027
[26]   A compact violet diode laser-based fluorescence lifetime microscope [J].
Ryder, AG ;
Glynn, TJ ;
Przyjalgowski, M ;
Szczupak, B .
JOURNAL OF FLUORESCENCE, 2002, 12 (02) :177-180
[27]   Stacking in capillary zone electrophoresis [J].
Shihabi, ZK .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :107-117
[28]   Analysis of riboflavin in beer by capillary electrophoresis/blue light emitting diode (LED)-induced fluorescence detection combined with a dynamic pH junction technique [J].
Su, AK ;
Chang, YS ;
Lin, CH .
TALANTA, 2004, 64 (04) :970-974
[29]   Determination of riboflavin in urine by capillary electrophoresis-blue light emitting diode-induced fluorescence detection combined with a stacking technique [J].
Su, AK ;
Lin, CH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (01) :39-46
[30]   Simple double-beam absorption detection systems for capillary electrophoresis based on diode lasers and light-emitting diodes [J].
Tong, W ;
Yeung, ES .
JOURNAL OF CHROMATOGRAPHY A, 1995, 718 (01) :177-185