High-frequency (20-MHz) high-intensity focused ultrasound (HIFU) system for dermal intervention: Preclinical evaluation in skin equivalents

被引:39
作者
Bove, Torsten [1 ]
Zawada, Tomasz [1 ]
Serup, Jorgen [2 ]
Jessen, Alexander [1 ]
Poli, Mattia [1 ]
机构
[1] TOOsonix AS, Horsholm, Denmark
[2] Bispebjerg Hosp, Dept Dermatol, Copenhagen, Denmark
关键词
ablative; animal tissue model; ex vivo high-intensity focused ultrasound; in vitro high-intensity focused ultrasound; non-ablative; non-invasive; small animal model; tissue-mimicking phantom; ultrasonic transducer; SURGERY;
D O I
10.1111/srt.12661
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background High-intensity focused ultrasound (HIFU) for non-invasive treatment of a range of internal pathologies including cancers of major organs and cerebral pathologies is in exponential growth. Systems, however, operate at relatively low frequencies, in the range of 200-2000 kHz as required for deep axial penetration of the body. HIFU utilizing frequencies in excess of 15 MHz has so far not been explored, but presents an opportunity to extend the HIFU modality to target specific dermal lesions and small animal research. Materials and methods A new 20-MHz HIFU system (TOOsonix ONE-R) with narrow focus corresponding to the dermis was studied in acoustic skin equivalents, for example, in a tissue-mimicking gel and in bovine liver. HIFU lesion geometry, depth, and diameter were determined. The temperature increase in the focal point was measured as a function of acoustic power and the duration of HIFU exposure. Results The system produces highly reproducible ultrasound lesions with predictable and configurable depths of 1-2 mm, thus corresponding to the depth of the human dermis. The lesion geometry was elongated triangular and sized 0.1-0.5 mm, convergent to a focal point skin deep. Focal point temperature ranged between 40 and 90 degrees C depending on the chosen setting. Observations were confirmed ex vivo in bovine liver and porcine muscle. Variation of acoustic power and duration of exposure produced linear effects in the range of the settings studied. Thus, effects could be adjusted within the temperature interval and spatial field relevant for clinical therapy and experimental intervention targeting the dermal layer of human skin. Conclusion The tested 20-MHz HIFU system for dermal applications fulfilled key prerequisite of narrow-field HIFU dedicated to cutaneous applications regarding reproducibility, geometry, and small size of the applied ultrasound lesions. Controlled adjustment of acoustic lesions within the temperature range 40-90 degrees C qualifies the system for a range of non-ablative and ablative applications in dermatological therapy.
引用
收藏
页码:217 / 228
页数:12
相关论文
共 30 条
[1]   The road to clinical use of high-intensity focused ultrasound for liver cancer: technical and clinical consensus [J].
Aubry, Jean-Francois ;
Pauly, Kim Butts ;
Moonen, Chrit ;
ter Haar, Gail ;
Ries, Mario ;
Salomir, Rares ;
Sokka, Sham ;
Sekins, Kevin Michael ;
Shapira, Yerucham ;
Ye, Fangwei ;
Huff-Simonin, Heather ;
Eames, Matt ;
Hananel, Arik ;
Kassell, Neal ;
Napoli, Alessandro ;
Hwang, Joo Ha ;
Wu, Feng ;
Zhang, Lian ;
Melzer, Andreas ;
Kim, Young-sun ;
Gedroyc, Wladyslaw M. .
JOURNAL OF THERAPEUTIC ULTRASOUND, 2013, 1
[2]   Minimally invasive treatments of painful bone lesions: state of the art [J].
Barile, Antonio ;
Arrigoni, Francesco ;
Zugaro, Luigi ;
Zappia, Marcello ;
Cazzato, Roberto Luigi ;
Garnon, Julien ;
Ramamurthy, Nitin ;
Brunese, Luca ;
Gangi, Afshin ;
Masciocchi, Carlo .
MEDICAL ONCOLOGY, 2017, 34 (04)
[3]  
Carlsen KH, 2017, CURR PROBL DERMATOL, V52, P124, DOI 10.1159/000450813
[4]   Focused ultrasound induced hyperthermia accelerates and increases the uptake of anti-HER-2 antibodies in a xenograft model [J].
Centelles, Miguel N. ;
Wright, Michael ;
Gedroyc, Wladyslaw ;
Thanou, Maya .
PHARMACOLOGICAL RESEARCH, 2016, 114 :144-151
[5]   High intensity focused ultrasound as a potential new modality for the treatment of pigmentary skin disorder [J].
Choi, S. Y. ;
Yoo, K. H. ;
Oh, C. T. ;
Kwon, T. R. ;
Choi, E. J. ;
Seok, J. ;
Kim, B. J. .
SKIN RESEARCH AND TECHNOLOGY, 2016, 22 (02) :131-136
[6]  
Day D., 2014, RES REP FOCUSED ULTR, V2, P13
[7]  
Divkovic G, 2005, AIP CONF PROC, V754, P143, DOI 10.1063/1.1901622
[8]   Preclinical MRI-Guided Focused Ultrasound: A Review of Systems and Current Practices [J].
Ellens, Nicholas P. K. ;
Partanen, Ari .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (01) :291-305
[9]   Hyperthermia-enhanced targeted drug delivery using magnetic resonance-guided focussed ultrasound: a pre-clinical study in a genetic model of pancreatic cancer [J].
Farr, Navid ;
Wang, Yak-Nam ;
D'Andrea, Samantha ;
Starr, Frank ;
Partanen, Ari ;
Gravelle, Kayla M. ;
McCune, Jeannine S. ;
Risler, Linda J. ;
Whang, Stella G. ;
Chang, Amy ;
Hingorani, Sunil R. ;
Lee, Donghoon ;
Hwang, Joo Ha .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2018, 34 (03) :284-291
[10]  