Study on Tower Models for EHV Transmission Line

被引:0
|
作者
Xu, Bao-Qing [1 ]
Zhang, Xiao-Fei [1 ]
Lv, Sen [1 ]
Ding, Rui-Xin [1 ]
Wang, Lu [2 ]
机构
[1] Sanmenxia Power Supply Co, State Grid Henan Elect Power Co, Sanmenxia, Peoples R China
[2] North China Elect Power Univ, Baoding, Peoples R China
关键词
D O I
10.1051/matecconf/20165608006
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Lightning outage accident is one of the main factors that threat seriously the safe and reliable operation of power system. So it is very important to establish reasonable transmission tower model and evaluate the impulse response characteristic of lightning wave traveling on the transmission tower properly for determining reliable lightning protection performance. With the help of Electromagnetic Transient Program (EMTP), six 500kV tower models are built. Aiming at one line to one transformer operating mode of 500kV substation, the intruding wave overvoltage under different tower models is calculated. The effect of tower model on intruding overvoltage has been studied. The results show that different tower models can result in great differences to the calculation results. Hence, reasonable selection of the tower model in the calculation of back-strike intruding wave is very important.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Seismic Analysis of Transmission Tower Line Systems
    Vaisakh, P. V.
    Nair, Neeraja
    PROCEEDINGS OF STRUCTURAL ENGINEERING AND CONSTRUCTION MANAGEMENT, SECON'19, 2020, 46 : 589 - 596
  • [42] A Mechanical Model of Single Transmission Line Tower
    Jin, Zhihong
    PROCEEDINGS OF THE 2017 5TH INTERNATIONAL CONFERENCE ON FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY (FMSMT 2017), 2017, 130 : 951 - 954
  • [43] Stability Analysis of Tower Foundation for Transmission Line
    Chen, Zhen
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 490 - 493
  • [44] EVOLVING AN EHV TOWER CONFIGURATION.
    Khanna, R.L.
    Sehra, H.S.
    Irrigation and Power, 1975, 32 (03): : 309 - 323
  • [46] Study of Wind Induced Vibration of Transmission Power Tower-line System
    Yang, Weijun
    Liang, Longteng
    APPLIED MECHANICS, MATERIALS AND MANUFACTURING IV, 2014, 670-671 : 1125 - 1129
  • [47] Study on the influence of insulator on the coupling effect of transmission tower-line system
    Gao, Qingshui
    Liu, Shi
    Yang, Yi
    Zhang, Chu
    2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS AND CONTROL ENGINEERING (ISPECE 2018), 2019, 1187
  • [48] Experimental study on features of galloping response of tower-line system for transmission
    Yang, Lun
    Lou, Wenjuan
    Chen, Yong
    Yan, Dong
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2013, 41 (11): : 46 - 52
  • [49] Experimental Study on the Influence of Transmission Lines on Tower-Line System Dynamics
    Gao, Qing-shui
    Liu, Shi
    Tian, Feng
    2018 INTERNATIONAL CONFERENCE ON COMPUTER, COMMUNICATIONS AND MECHATRONICS ENGINEERING (CCME 2018), 2018, 332 : 190 - 195
  • [50] Study on the collapse failure of transmission tower-line system under downburst
    Bi W.-Z.
    Tian L.