Comparison between gutta-percha and Resilon removal using two different techniques in endodontic retreatment

被引:57
作者
de Oliveira, DP
Barbizam, JVB
Trope, M
Teixeira, FB
机构
[1] Univ N Carolina, Sch Dent, Dept Endodont, Chapel Hill, NC 27599 USA
[2] Univ Estadual Campinas, Piracicaba Sch Dent, Dept Endodont, Piracicaba, SP, Brazil
[3] UNESP, Araraquara Dent Sch, Dept Endodont, Araraquara, SP, Brazil
关键词
endodontic retreatment; Resilon; rotary files;
D O I
10.1016/j.joen.2005.12.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study compared the remaining filling material and working time when removing gutta-percha/AH 26 and Resilon/Epiphany from root filled extracted teeth. The root fillings were removed using chloroform and two different rotary systems (K3 and Liberator files). The amount of residual filling material on the canal walls was imaged and measured using image analyzer software. The group filled with Resilon/Epiphany and retreated with K3 files demonstrated the least residual filling material on the walls (p < 0.05). There was no statistically significant difference between the guttapercha/AH26 and Resilon/Epiphany groups when the Liberator files were used (p > 0.05). In the groups filled with Resilon/Epiphany, the filling was removed faster than groups filled with gutta-percha/AH 26 (p < 0.05). K3 rotary system was faster than Liberator to remove both gutta-percha and Resilon (p < 0.05). Resilon/ Epiphany was effectively removed with K3 or Liberator rotary files.
引用
收藏
页码:362 / 364
页数:3
相关论文
共 30 条
[1]  
BARLETTA FB, 2002, ENDODONCIA, V20, P189
[2]  
BERGENHOLTZ G, 1979, SCAND J DENT RES, V87, P217
[3]   Efficacy of Quantec rotary instruments for gutta-percha removal [J].
Bramante, CM ;
Betti, LV .
INTERNATIONAL ENDODONTIC JOURNAL, 2000, 33 (05) :463-467
[4]   Effect of rotational speed on the breakage of nickel-titanium rotary files [J].
Dietz, DB ;
Di Fiore, PM ;
Bahcall, JK ;
Lautenschlager, EP .
JOURNAL OF ENDODONTICS, 2000, 26 (02) :68-71
[5]   The efficacy of gutta-percha removal using ProFiles [J].
Ferreira, JJ ;
Rhodes, JS ;
Ford, TRP .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (04) :267-274
[6]   ENDODONTIC RETREATMENT - CASE SELECTION AND TECHNIQUE .1. CRITERIA FOR CASE SELECTION [J].
FRIEDMAN, S ;
STABHOLZ, A .
JOURNAL OF ENDODONTICS, 1986, 12 (01) :28-35
[7]   Effect of rotational speed on nickel-titanium file distortion [J].
Gabel, WP ;
Hoen, M ;
Steiman, HR ;
Pink, FE ;
Dietz, R .
JOURNAL OF ENDODONTICS, 1999, 25 (11) :752-754
[8]  
Glickman G N, 1997, Alpha Omegan, V90, P29
[9]   Efficacy, cleaning ability and safety of different rotary NiTi instruments in root canal retreatment [J].
Hülsmann, M ;
Bluhm, V .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (07) :468-476
[10]  
Hulsmann M, 1997, INT ENDOD J, V30, P227