Measured Impedance by Distance Relay Elements in a Single Phase to Ground Fault

被引:0
|
作者
Shateri, H. [1 ]
Jamali, S. [1 ]
机构
[1] IUST, Dept Elect Engn, Ctr Excellence Power Syst Automat & Operat, Tehran 16846, Iran
来源
PROCEEDINGS OF ICECE 2008, VOLS 1 AND 2 | 2008年
关键词
D O I
10.1109/ICECE.2008.4769296
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Distance relays are one of the mostly used protective devices in the transmission systems. These relays are used as the main and backup protective device. Fault resistance is a source of error for distance relays in the form of the measured impedance deviation from its actual value. This paper discusses the measured impedance by six elements of distance relay first zone in the case of a single phase to ground (AG) fault. This is done by presenting the measured impedance at the relaying point and the distance relay ideal tripping characteristic for each element. The variation of the ideal tripping characteristic due to the changes in the power system parameters is investigated.
引用
收藏
页码:682 / 687
页数:6
相关论文
共 50 条
  • [31] Effect of SSSC on measured impedance of distance relay in double-circuit lines
    Jamali, S.
    Kazeini, A.
    Shaterl, H.
    2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2007, : 895 - 899
  • [32] Effects of UPFC on Measured Impedance by Distance Relay in Double-Circuit Lines
    Jamali, S.
    Kazemi, A.
    Shateri, H.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 3601 - 3608
  • [33] A Comparative Study of High Impedance Fault in Transmission Line using Distance Relay
    Patel, Tapas Kumar
    Mohanty, Subodh Kumar
    Chand, Ricky
    2017 4TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND COMMUNICATION SYSTEMS (ICACCS), 2017,
  • [34] Effects of Instrument Transformers Connection Point on Measured Impedance by Distance Relay in Presence of SSSC
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    SCIENTIA IRANICA, 2008, 15 (06) : 517 - 524
  • [35] Effects of instrument transformers connection point on measured impedance by distance relay in presence of SSSC
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2467 - 2472
  • [36] Research on Summation Impedance Relay with Ability to Identify High-Resistance Ground Fault
    He, Shan
    Shao, Chong
    Xu, Chen
    Zhang, Rui
    Lin, Xiangning
    Weng, Liguo
    2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [37] Impedance estimation including ground fault resistance error correction for distance protection
    Funk, AT
    Malik, OP
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2000, 22 (01) : 59 - 66
  • [38] Sensitivity analysis of a single phase to ground fault system in connection with high impedance faults: A case study
    Velmurugan, Perumal
    Chattopadhayay, Adhir Baran
    COGENT ENGINEERING, 2020, 7 (01):
  • [39] 1-ohm Impedance Criterion for Diagnosis of Single-Phase Ground Fault of Transmission Line
    Zhou, Xueming
    Wang, Xiankang
    Yao, Yao
    Feng, Zhiqiang
    Hu, Zixuan
    Fu, Jianjin
    Li, Zijian
    IEEE ACCESS, 2025, 13 : 1680 - 1687
  • [40] Ground-Fault Loop Impedance Calculations in Low-Voltage Single-Phase Systems
    Liu, Haijun
    Mitolo, Massimo
    Qiu, Jun
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (02) : 1331 - 1337