Measured Impedance by Distance Relay Elements in a Single Phase to Ground Fault

被引:0
|
作者
Shateri, H. [1 ]
Jamali, S. [1 ]
机构
[1] IUST, Dept Elect Engn, Ctr Excellence Power Syst Automat & Operat, Tehran 16846, Iran
来源
PROCEEDINGS OF ICECE 2008, VOLS 1 AND 2 | 2008年
关键词
D O I
10.1109/ICECE.2008.4769296
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Distance relays are one of the mostly used protective devices in the transmission systems. These relays are used as the main and backup protective device. Fault resistance is a source of error for distance relays in the form of the measured impedance deviation from its actual value. This paper discusses the measured impedance by six elements of distance relay first zone in the case of a single phase to ground (AG) fault. This is done by presenting the measured impedance at the relaying point and the distance relay ideal tripping characteristic for each element. The variation of the ideal tripping characteristic due to the changes in the power system parameters is investigated.
引用
收藏
页码:682 / 687
页数:6
相关论文
共 50 条
  • [21] Measured Impedance by Distance Relay for Inter Phase Faults in Presence of SSSC on a Double Circuit Transmission Line
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    2008 IEEE REGION 10 CONFERENCE: TENCON 2008, VOLS 1-4, 2008, : 423 - 428
  • [22] Method for Protection of Single-Line-Ground Fault of Distribution System with DG Using Distance Relay and Directional Relay
    Lee, Jung-Hun
    Park, Min-Su
    Ahn, Hong-Seon
    Park, Kyung-Won
    Oh, Jun-Seok
    Jeon, Seung-Gyu
    Kim, Dong-Kyu
    Kim, Jae-Eon
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (04) : 1607 - 1616
  • [23] Measured impedance by distance relay considering double π model of the line capacitance
    Jamali, S.
    Shateri, H.
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2505 - 2511
  • [24] Ground distance relay compensation based on fault resistance calculation
    Eissa, M. M.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (04) : 1830 - 1835
  • [25] Modeling and Simulation of Impedance Distance Relay for Fault Location and Protection of Single Wire Earth Return Line
    Ashagire, Amare A.
    Adjallah, Kondo H.
    Bekele, Getachew
    2019 IEEE 2ND UKRAINE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (UKRCON-2019), 2019, : 1196 - 1200
  • [26] Digital algorithm for distance relay including grounding impedance at fault place
    Radojevic, ZM
    Popovic, LM
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2002, 12 (04): : 269 - 274
  • [27] Ground-Fault Loop Impedance Calculations in Single-Phase Systems
    Liu, Haijun
    Mitolo, Massimo
    Qiu, Jun
    2013 49TH IEEE/IAS INDUSTRIAL & COMMERCIAL POWER SYSTEMS TECHNICAL CONF (I&CPS), 2013,
  • [28] Steady-state error estimation in distance relay for single phase to ground fault in series-compensated parallel transmission lines
    Venkatesh, C.
    Swarup, K. Shanti
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (07) : 1318 - 1337
  • [29] Effects of instrument transformers location on measured impedance by distance relay in presence of UPFC
    Jamali, S.
    Kalantar, M.
    Shateri, H.
    2006 IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2006, : 715 - +
  • [30] Measured Impedance by Distance Relay with Positive Sequence Voltage Memory in Presence of TCSC
    Kazemi, A.
    Jamali, S.
    Shateri, H.
    2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, 2009, : 1339 - 1344