0.2-tesla magnetic resonance imaging of internal lesions of the knee joint: a prospective arthroscopically controlled clinical study

被引:33
作者
Riel, KA
Reinisch, M
Kersting-Sommerhoff, B
Hof, N
Merl, T
机构
[1] Tech Univ Munich, Abt & Poliklin Sportorthopad, D-80809 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Inst Rontgendiagnost, D-8000 Munich, Germany
关键词
low-field MRI; knee joint; arthroscopy;
D O I
10.1007/s001670050118
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The results of magnetic resonance imaging (MRI) were compared with those of arthroscopy in a prospective series of 244 patients. A dedicated system for MRI of limbs and peripheral joints - the 0,2-T Artoscan (Esaote, Italy)- was used for imaging knee joint lesions. T1-weighted spin-echo sagittal images, T2-weighted gradient-echo coronal images, and axial views for lesions of the femoropatellar joint were acquired. Paraxial sagittal and oblique coronal views were obtained for imaging of the cruciate ligaments. This protocol allowed excellent visualization of the cruciate ligaments and medial and lateral meniscus in almost all patients. Compared with arthroscopy performed within 48 h after imaging, the sensitivity, specificity, and accuracy were respectively 93%, 97%, and 95% for tears of the medial meniscus; 82%, 96%, and 93% for tears of the lateral meniscus; 100%, 100%, and 100% for tears of the posterior cruciate ligament; 98%, 98%, and 97% for tears of the anterior cruciate ligament; and 72%, 100%, and 92% for full-thickness articular cartilage lesions. The examination can be performed within 30-45 min at lower cost than diagnostic arthroscopy. MRI with a 0.2-T magnet is a safe and valuable adjunct to the clinical examination of the knee and an aid to efficient preoperative planning.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 23 条
[1]  
Boden S D, 1990, Arthroscopy, V6, P306, DOI 10.1016/0749-8063(90)90061-H
[2]   MAGNETIC-RESONANCE-IMAGING OF MENISCAL AND CRUCIATE INJURIES OF THE KNEE [J].
BOEREE, NR ;
WATKINSON, AF ;
ACKROYD, CE ;
JOHNSON, C .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (03) :452-457
[3]  
BROWN TR, 1993, SKELETAL RADIOL, V22, P325
[4]   MRI can prevent unnecessary arthroscopy [J].
Carmichael, IW ;
MacLeod, AM ;
Travlos, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (04) :624-625
[5]   Arthroscopy and MRI for the knee [J].
Dandy, DJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (04) :520-520
[6]  
ENGEL A, 1994, ORTHOPADE, V23, P112
[7]  
FICAT RP, 1979, CLIN ORTHOP RELAT R, P55
[8]   ACCURACY OF DIAGNOSES FROM MAGNETIC-RESONANCE-IMAGING OF THE KNEE - A MULTICENTER ANALYSIS OF 1014 PATIENTS [J].
FISCHER, SP ;
FOX, JM ;
DELPIZZO, W ;
FRIEDMAN, MJ ;
SNYDER, SJ ;
FERKEL, RD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :2-10
[9]  
Franklin PD, 1997, AM J SPORT MED, V25, P382
[10]  
Gerhardt P, 1994, Rontgenpraxis, V47, P4