Exergy analysis of the building heating and cooling system from the power plant to the building envelop with hourly variable reference state

被引:32
作者
Zhou, Yan [1 ,2 ]
Gong, Guangcai [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
[2] Ningbo Univ, Fac Architectural Civil Engn & Environm, Ningbo 315211, Zhejiang, Peoples R China
关键词
Building envelop; Exergy; Efficiency; Heating and cooling; ENERGY USE; PUMP; AIR;
D O I
10.1016/j.enbuild.2012.09.041
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Exergy method is applied to analyze the heating and cooling system of an example building. The exergy flow rate is calculated from the power plant to the building envelop with hourly outdoor temperature and humidity as reference state. The chemical exergy of room air is considered in cooling mode. Three cases of improvements together with a standard case are analyzed using this method. Results show that building envelop insulation is necessary in the hot summer and cold winter area of China in reducing the building exergy consumption. On the premise of envelop necessary insulation, the more effective energy efficiency solution of the building is to increase the air conditioner efficiency rather than increase the envelop insulation layer. The total year larger exergy loss rates take place in the primary energy transformation and heating/cooling production, which is about 80% of the system's total exergy loss. Variable reference state needs to be considered when it is relatively close to the interior conditions of a building. The room air chemical exergy is about 12% of the physical exergy. So the chemical exergy should not be ignored in cooling mode. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:94 / 99
页数:6
相关论文
共 22 条
[1]   Exergy analysis of air cooling systems in buildings in hot humid climates [J].
Alpuche, MG ;
Heard, C ;
Best, R ;
Rojas, J .
APPLIED THERMAL ENGINEERING, 2005, 25 (04) :507-517
[2]   Evaluating a low exergy heating system from the power plant through the heat pump to the building envelope [J].
Balta, M. Tolga ;
Kalinci, Yildiz ;
Hepbasli, Arif .
ENERGY AND BUILDINGS, 2008, 40 (10) :1799-1804
[3]  
Building Energy Research Centre of Tsinghai University, 2008, ANN REP CHIN BUILD E, P5
[4]   Exergetic and sustainability performance comparison of novel and conventional air cooling systems for building applications [J].
Caliskan, Hakan ;
Dincer, Ibrahim ;
Hepbasli, Arif .
ENERGY AND BUILDINGS, 2011, 43 (06) :1461-1472
[5]   Analysis on exergy consumption patterns for space heating in Slovenian buildings [J].
Dovjak, Mateja ;
Shukuya, Masanori ;
Olesen, Bjarne W. ;
Krainer, Ales .
ENERGY POLICY, 2010, 38 (06) :2998-3007
[6]   A comparative investigation of various greenhouse heating options using exergy analysis method [J].
Hepbasli, Arif .
APPLIED ENERGY, 2011, 88 (12) :4411-4423
[7]   Validation and evaluation of total energy use in office buildings: A case study [J].
Korjenic, Azra ;
Bednar, Thomas .
AUTOMATION IN CONSTRUCTION, 2012, 23 :64-70
[9]   Exergy analysis for day lighting, electric lighting and space cooling systems for a room space in a tropical climate [J].
Mahlia, T. M. I. ;
Taufiq, B. N. ;
Ong, K. P. ;
Saidur, R. .
ENERGY AND BUILDINGS, 2011, 43 (07) :1676-1684
[10]  
Pan C., 2008, THESIS HEFEI U TECHN