Oxygen transmissibility of piggyback systems with conventional soft and silicone hydrogel contact lenses

被引:20
作者
López-Alemany, A
González-Méijome, JM
Almeida, JB
Parafita, MA [1 ]
Refojo, MF
机构
[1] Univ Santiago de Compostela, Sch Opt & Optometry, Dept Surg Ophthalmol, Santiago De Compostela 15782, Spain
[2] Univ Valencia, Sch Optometry Opt, Dept Opt, Ocular Surface Cornea & Contact Lens Res Grp, Valencia, Spain
[3] IOOC, Novetle, Spain
[4] Univ Minho, Sch Sci, Dept Phys Optometry, Braga, Portugal
[5] Harvard Univ, Sch Med, Schepens Eye Res Inst, Boston, MA 02115 USA
关键词
oxygen transmission; contact lens; piggyback;
D O I
10.1097/01.ico.0000178276.90892.ac
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the apparent oxygen transmissibility of various piggyback systems using conventional and silicone hydrogel soft contact lenses of different water content and permeability, rigid poly(methyl methacrylate), and rigid gas-permeable lenses of medium, high, and ultrahigh oxygen permeability. The aim of the study was to establish which material (rigid or hydrogel) is more representative of the resulting oxygen performance of piggyback systems. Methods: The apparent oxygen transmissibility of 66 piggyback systems was measured with an electrochemical method. Eighteen of these combinations involved the use of silicone hydrogel contact lenses currently available. One hyperpermeable rigid gas-permeable contact lens (tisilfocon A) was also included in the study. Results: Measured apparent transmissibility correlates with rigid lens permeability (r(2) = 0.403; SE = +/- 3.03 barrer/cm; P < 0.001) and hydrogel lens permeability (r(2) = 0.334; SE = +/- 3.2 barrer/cm; P < 0.001). As expected, a linear model comprising permeability values from both rigid and soft materials gave a more precise estimation of the piggyback transmissibility (r(2) = 0.736; SE = +/- 2.02 barrer/cm; P < 0.001). The highest values of apparent oxygen transmissibility were found for the combination of tisilfocon A rigid material with any of the 3 silicone hydrogel lenses. Tisilfocon A material significantly improved the transmissibility of all piggyback systems even when conventional hydrogels are involved. Conclusion: The combination of hypertransmissible rigid gas permeable lenses with silicone hydrogel soft materials should result in normal corneal function under daily wear conditions. When fitting piggyback systems, clinicians must be aware of material selection to optimize oxygen performance. This is of particular importance in already compromised corneas.
引用
收藏
页码:214 / 219
页数:6
相关论文
共 27 条
  • [1] RAPID DETERMINATION OF OXYGEN PERMEABILITY OF POLYMER MEMBRANES
    AIBA, S
    OHASHI, M
    HUANG, SY
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1968, 7 (03): : 497 - &
  • [2] Contact lens fitting to correct irregular astigmatism after corneal refractive surgery
    Alió, JL
    Belda, JI
    Artola, A
    García-Lledó, M
    Osman, A
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (10) : 1750 - 1757
  • [3] BALDONE JA, 1995, CONTACT LENSES CLAO, V3, P91
  • [4] Visual performance and comfort with the Rose K lens for keratoconus
    Betts, AM
    Mitchell, GL
    Zadnik, K
    [J]. OPTOMETRY AND VISION SCIENCE, 2002, 79 (08) : 493 - 501
  • [5] CAROLINE PJ, 2002, CONTACT LENS PRACTIC, P332
  • [6] Optimization of contact lens fitting in keratectasia patients after laser in situ keratomileusis
    Choi, HJ
    Kim, MK
    Lee, JL
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (05) : 1057 - 1066
  • [7] Fitting contact lenses after myopic keratomileusis
    Chou, AC
    Swinger, CA
    Cogger, SK
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (04) : 508 - 513
  • [8] Chung Christine W., 2001, CLAO Journal, V27, P202
  • [9] Edmonds Charles R, 2004, Eye Contact Lens, V30, P54, DOI 10.1097/01.ICL.0000105561.89689.C8
  • [10] RIGID LENS TEAR PUMP EFFICIENCY - EFFECTS OF OVERALL DIAMETER BASE CURVE COMBINATIONS
    FINK, BA
    CARNEY, LG
    HILL, RM
    [J]. OPTOMETRY AND VISION SCIENCE, 1991, 68 (04) : 309 - 313