Sensitivity analysis and multi-objective optimization of energy consumption and thermal comfort by using interior light shelves in residential buildings

被引:75
作者
Ebrahimi-Moghadam, Amir [1 ,2 ]
Ildarabadi, Paria [3 ]
Aliakbari, Karim [4 ]
Fadaee, Faramarz [3 ]
机构
[1] Shahrood Univ Technol, Fac Mech Engn, Shahrood, Iran
[2] Aalborg Univ, Dept Energy Technol, Aalborg, Denmark
[3] Khorasan Inst Higher Educ, Mashhad, Razavi Khorasan, Iran
[4] Tech & Vocat Univ TVU, Fac Montazeri, Dept Mech Engn, Khorasan Razavi Branch, Mashhad, Razavi Khorasan, Iran
关键词
Daylight; Light shelf; Thermal comfort; Energy consumption; Optimization; OFFICE BUILDINGS; PERFORMANCE; PMV; MANAGEMENT; SYSTEMS; DESIGN;
D O I
10.1016/j.renene.2020.05.127
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Sunlight is one of the most accessible environmental agents which has been used as primary energy source. In current study, the effect of daylight distribution in interior spaces on human thermal comfort conditions and energy consumption in the residential buildings is investigated based on light shelf using simulation methods and tools. Firstly, a comprehensive parametric study is presented to examine the impact of light shelf design parameters (including angle, depth and number of the light shelves) on two objective functions of building's total energy consumption (including heating, cooling and electrical energy) and predicted percentage of dissatisfied people. Then, employing genetic algorithm, a multi objective optimization is conducted in order to minimize the two objective functions simultaneously. Light shelves are evaluated for three orientations of West, South and East; horizontally and vertically. Results show that the optimum angle, depth and number of light shelves for West orientation are 24.37 degrees, 0.571 m and 5, respectively; for South orientation are 89.62 degrees, 0.295 m and 4, respectively; for East orientation are 36.51 degrees, 0.659 m and 4, respectively. In addition, results indicate that optimum conditions of light shelves decreases the total heating, cooling and electrical energy consumption by 27.819 kWh/m(2), 49.176 kWh/m(2) and 34.853 kWh/m(2), respectively. (c) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:736 / 755
页数:20
相关论文
共 38 条
[1]   A comparative study of various daylighting systems in office buildings for improving energy efficiency in Egypt [J].
Ahmad, Rehab M. ;
Reffat, Rabee M. .
JOURNAL OF BUILDING ENGINEERING, 2018, 18 :360-376
[2]   Energy saving potential of phase change materials in major Australian cities [J].
Alam, Morshed ;
Jamil, Hasnat ;
Sanjayan, Jay ;
Wilson, John .
ENERGY AND BUILDINGS, 2014, 78 :192-201
[3]  
ANSI/ASHRAE, 2004, 1402001 ANSIASHRAE
[4]  
ASHRAE, 2019, ASHRAE/IESNA Standard 90.1-2019
[5]  
ASHRAE A, 2010, 552013 ANSIASHRAE
[6]   New parameters to evaluate the capability of a daylight-linked control system in complementing daylight [J].
Bellia, Laura ;
Fragliasso, Francesca .
BUILDING AND ENVIRONMENT, 2017, 123 :223-242
[7]   Analysis of the Impacts of Light Shelves on the Useful Daylight Illuminance in Office Buildings in Toronto [J].
Berardi, Umberto ;
Anaraki, Hamid Khademi .
6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 :1793-1798
[8]   Passive cooling in a low-energy office building [J].
Breesch, H ;
Bossaer, A ;
Janssens, A .
SOLAR ENERGY, 2005, 79 (06) :682-696
[9]   A simulation-aided approach in improving thermal-visual comfort and power efficiency in buildings [J].
Cheong, Kang Hao ;
Teo, Ya Hui ;
Koh, Jin Ming ;
Acharya, U. Rajendra ;
Yu, Simon Ching Man .
JOURNAL OF BUILDING ENGINEERING, 2020, 27
[10]   Analysis of the accuracy on PMV - PPD model using the ASHRAE Global Thermal Comfort Database II [J].
Cheung, Toby ;
Schiavon, Stefano ;
Parkinson, Thomas ;
Li, Peixian ;
Brager, Gail .
BUILDING AND ENVIRONMENT, 2019, 153 :205-217