Comparison of the capability of peak functions in describing real chromatographic peaks

被引:52
作者
Li, JW [1 ]
机构
[1] 3M Co, Pharmaceut, 3M Ctr, Analyt Res & Dev, St Paul, MN 55144 USA
关键词
peak functions; peak modeling; curve fitting; moment analysis; deconvolution;
D O I
10.1016/S0021-9673(02)00090-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes the results of a comparison of four peak functions in describing real chromatographic peaks, They are the empirically transformed Gaussian, polynomial modified Gaussian. generalized exponentially modified Gaussian and hybrid function of Gaussian and truncated exponential functions. Real chromatographic peaks of different shapes (fronting, symmetric, and tailing) are obtained by various separation conditions of reversed-phase liquid chromatography. They are then fitted to the peak functions via the Marquardt-Levenberg algorithm. a nonlinear least-squares curve-fitting procedure. by Microsoft Solver. The qualities of the fits are evaluated by the sum of the squares of the residuals, It is concluded in the study that the empirically transformed Gaussian function offers the highest flexibility (best fits) to all shapes of chromatographic peaks, including extremely asymmetric tailing peaks with a peak asymmetry of up to S. The flexibility of this function should improve our ability to process chromatographic peaks such as deconvolution of overlapped peaks and smoothing noisy peaks for the determination of statistical moments. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 17 条
[1]   EFFECT OF PEAK SENSING AND RANDOM NOISE ON PRECISION AND ACCURACY OF STATISTICAL MOMENT ANALYSES FROM DIGITAL CHROMATOGRAPHIC DATA [J].
CHESLER, SN ;
CRAM, SP .
ANALYTICAL CHEMISTRY, 1971, 43 (14) :1922-&
[2]   HIGH-PERFORMANCE GEL-PERMEATION CHROMATOGRAPHY OF POLYSTYRENE WITH SILICA MICROSPHERES [J].
DAWKINS, JV ;
YEADON, G .
JOURNAL OF CHROMATOGRAPHY, 1980, 188 (02) :333-345
[3]   COMPUTER CHARACTERIZATION OF CHROMATOGRAPHIC PEAKS BY PLATE HEIGHT AND HIGHER CENTRAL MOMENTS [J].
GRUSHKA, E ;
MYERS, MN ;
SCHETTLER, PD ;
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1969, 41 (07) :889-+
[4]  
Grushka E., 1975, METHODS PROTEIN SEPA, p161?192
[5]   REVIEW OF THE EXPONENTIALLY MODIFIED GAUSSIAN (EMG) FUNCTION SINCE 1983 [J].
JEANSONNE, MS ;
FOLEY, JP .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (06) :258-266
[6]  
JONSSON JA, 1987, CHROMATOGRAPHIC THEO, P27
[8]   A hybrid of exponential and gaussian functions as a simple model of asymmetric chromatographic peaks [J].
Lan, K ;
Jorgenson, JW .
JOURNAL OF CHROMATOGRAPHY A, 2001, 915 (1-2) :1-13
[9]   Development and evaluation of flexible empirical peak functions for processing chromatographic peaks [J].
Li, JW .
ANALYTICAL CHEMISTRY, 1997, 69 (21) :4452-4462
[10]   Effect of temperature on the thermodynamic properties, kinetic performance, and stability of polybutadiene-coated zirconia [J].
Li, JW ;
Carr, PW .
ANALYTICAL CHEMISTRY, 1997, 69 (05) :837-843