Repeatability and reproducibility of retention data and band profiles on reversed-phase liquid chromatography columns III.: Results obtained with Kromasil C18 columns

被引:81
作者
Kele, M
Guiochon, G
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
关键词
band profiles; Kromasil C-18; stationary phases; LC; retention data;
D O I
10.1016/S0021-9673(99)00746-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The reproducibility of the retention data and the band profiles was investigated with Kromasil C-18 columns (silica-based monomeric type reversed-phase packing material). High precision data were obtained and statistically compared among five columns from the same batch (column-to-column reproducibility) and six columns, one from each of six different batches (batch-to-batch reproducibility). These data were acquired under five different sets of chromatographic conditions, for a group of 30 neutral, acidic and basic compounds selected as probes following an experimental protocol previously described. Data characterizing the retention time, the retention factor, the separation factor, the column efficiency and the peak asymmetry for the different probe compounds are reported. Factors describing the silica surface interaction with the selected probe compounds, such as the hydrophobic interaction selectivity, the steric selectivity, and the separation factors of basic compounds at different pH values were also determined. The influence of the underlying silica on these data and correlations between the chromatographic and physico-chemical properties of the different batches are discussed. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:423 / 453
页数:31
相关论文
共 54 条
[1]   PREPARATION OF VARIOUS BONDED PHASES FOR HPLC USING MONOCHLOROSILANES [J].
BERENDSEN, GE ;
PIKAART, KA ;
GALAN, LD .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1980, 3 (10) :1437-1464
[2]   Comparative characterization of octyl bonded phases using methylene selectivity data [J].
Bhagwat, V ;
Bereznitski, Y ;
Buszewski, B ;
Jaroniec, M .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (07) :923-939
[3]   Retention of ionizable compounds on HPLC. pH scale in methanol-water and the pK and pH values of buffers [J].
Bosch, E ;
Bou, P ;
Allemann, H ;
Roses, M .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3651-3657
[4]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[5]  
Buszewski B, 1998, HRC-J HIGH RES CHROM, V21, P267
[6]   Comparative study of test methods for reversed-phase columns for high-performance liquid chromatography [J].
Claessens, HA ;
van Straten, MA ;
Cramers, CA ;
Jezierska, M ;
Buszewski, B .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (02) :135-156
[7]   CHROMATOGRAPHIC AND SOLID-STATE NUCLEAR MAGNETIC-RESONANCE STUDY OF THE CHANGES IN REVERSED-PHASE PACKINGS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AT DIFFERENT ELUENT COMPOSITIONS [J].
CLAESSENS, HA ;
DEHAAN, JW ;
VANDEVEN, LJM ;
DEBRUYN, PC ;
CRAMERS, CA .
JOURNAL OF CHROMATOGRAPHY, 1988, 436 (03) :345-365
[8]   Chromatographic classification of commercially available reverse-phase HPLC columns [J].
Cruz, E ;
Euerby, MR ;
Johnson, CM ;
Hackett, CA .
CHROMATOGRAPHIA, 1997, 44 (3-4) :151-161
[9]   A SIMPLE TEST TO CHARACTERIZE C8/C18-BONDED PHASES, PARTICULARLY FOR TOXICOLOGICAL SCREENING [J].
DALDRUP, T ;
KARDEL, B .
CHROMATOGRAPHIA, 1984, 18 (02) :81-83
[10]  
Dorsey JG, 1998, ANAL CHEM, V70, p591R