Temperature-programmed packed capillary liquid chromatography separation with large volume on-column focusing of retinyl esters

被引:0
作者
Molander, P
Thommesen, SJ
Bruheim, IA
Trones, R
Greibrokk, T
Lundanes, E
Gundersen, TE
机构
[1] Univ Oslo, Dept Chem, N-0315 Oslo, Norway
[2] Univ Oslo, Inst Nutr Res, N-0316 Oslo, Norway
来源
HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY | 1999年 / 22卷 / 09期
关键词
large volume injection; packed capillary LC; temperature programming; retinyl esters; vitamin A;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A non-aqueous isocratic reversed-phase packed capillary high performance liquid chromatography method for the determination of retinyl esters, utilizing temperature programming and on-column focusing large volume injection, has been developed. The stationary phase material was C-30, and the mobile phase consisted of acetonitrile-dichloromethane (70:30, v/v). A three-step temperature program, starting at 10 degrees C for 10 min, then 1 degrees/min to 30 degrees C, and finally 2.5/min to 70 degrees C, was found most appropriate. Compared to an isothermal separation at 25 degrees C, this temperature program provided improved peak resolution, enhanced peak shapes of the last eluting compounds, and a reduction of the overall elution time. A mass limit of detection of 27 pg was found with respect to retinyl palmitate, using UV detection with an "U" shaped flow cell at 327 mm. This corresponds to a concentration limit of detection of 2.7 pg/mu L, when utilizing an injection volume of 10 mu L The concentration of retinyl palmitate in arctic seal If ver samples was estimated to be 62.6 mu g/g liver.
引用
收藏
页码:490 / 494
页数:5
相关论文
共 33 条
[1]   HPLC analysis of fat-soluble vitamins on standard and narrow bore columns with UV, electrochemical and particle beam MS detection [J].
Andreoli, R ;
Careri, M ;
Manini, P ;
Mori, G ;
Musci, M .
CHROMATOGRAPHIA, 1997, 44 (11-12) :605-612
[2]  
[Anonymous], 1982, EUR J BIOCHEM, V129, P1
[3]   Temperature dependence of carotenoids on C-18, C-30 and C-34 bonded stationary phases [J].
Bell, CM ;
Sander, LC ;
Wise, SA .
JOURNAL OF CHROMATOGRAPHY A, 1997, 757 (1-2) :29-39
[4]  
Blomhoff R., 1994, Vitamin A in health and disease., P1
[5]   MICROBORE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS - SPEED, EFFICIENCY, SENSITIVITY AND TEMPERATURE PROGRAMMING [J].
BOWERMASTER, J ;
MCNAIR, H .
JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV) :431-438
[6]   DETERMINATION OF TOLUENE DIISOCYANATE IN AIR USING MICRO LIQUID-CHROMATOGRAPHY WITH UV-DETECTION [J].
BRUNMARK, P ;
DALENE, M ;
SANGO, C ;
SKARPING, G ;
ERLANDSSON, P ;
DEWAELE, C .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1991, 3 (04) :371-375
[7]   MICRO LC ON CELLULOSE TRIACETATE (CTA) - INFLUENCE OF PARTICLE DIAMETER AND COLUMN TEMPERATURE [J].
CHEN, J ;
STEENACKERS, D ;
SANDRA, P .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1995, 7 (03) :259-263
[8]  
Chen MH, 1997, J CHROMATOGR A, V788, P51
[9]   Instrumental requirements for nanoscale liquid chromatography [J].
Chervet, JP ;
Ursem, M ;
Salzmann, JB .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1507-1512
[10]  
Djordjevic NM, 1999, J MICROCOLUMN SEP, V11, P403, DOI 10.1002/(SICI)1520-667X(1999)11:6<403::AID-MCS2>3.0.CO