Exergy analysis and optimization of R600a as a replacement of R134a in a domestic refrigerator system

被引:86
作者
Joybari, Mahmood Mastani [1 ]
Hatamipour, Mohammad Sadegh [1 ]
Rahimi, Amir [1 ]
Modarres, Fatemeh Ghadiri [2 ]
机构
[1] Univ Isfahan, Dept Chem Engn, Esfahan 8174673441, Iran
[2] Entekhab Ind Grp, R&D Dept, Esfahan, Iran
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2013年 / 36卷 / 04期
关键词
Exergy analysis; Taguchi experimental design; Domestic refrigerator; R134a; R600a; OPTIMUM WORKING-CONDITIONS; HEAT-EXCHANGER; TAGUCHI METHOD; PERFORMANCE ANALYSIS; DESIGN PARAMETERS; ISOBUTANE R600A; FINS; HYDROCARBON; MIXTURES; PUMPS;
D O I
10.1016/j.ijrefrig.2013.02.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
Exergy analysis was applied to investigate the performance of a domestic refrigerator originally manufactured to use 145 g of R134a. It was found that the highest exergy destruction occurred in the compressor followed by the condenser, capillary tube, evaporator, and superheating coil. Taguchi method was applied to design experiments to minimize exergy destruction while using R600a. Taguchi parameters were selected by the obtained results from R134a and an experiment using 60 g of R600a, which indicated similar results as R134a. Based on the outcomes, R600a charge amount, condenser fan rotational velocity and compressor coefficient of performance were selected for the design. The analysis of variance results indicated that R600a charge amount was the most effective parameter. At the optimum condition, the amount of charge required for R600a was 50 g, 66% lower than R134a one, which not only brings economic advantages, but also significantly reduces the risk of flammability of the hydrocarbon refrigerant. (C) 2013 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1233 / 1242
页数:10
相关论文
共 58 条
[11]   A Taguchi approach for investigation of heat transfer from a surface equipped with rectangular blocks [J].
Bilen, K ;
Yapici, S ;
Celik, C .
ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (08) :951-961
[12]  
Bolaji BO, 2010, J ENG SCI TECHNOL, V5, P435
[13]   The next generation of refrigerants - Historical review, considerations, and outlook [J].
Calm, James M. .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2008, 31 (07) :1123-1133
[14]   Performance and heat transfer characteristics of hydrocarbon refrigerants in a heat pump system [J].
Chang, YS ;
Kim, MS ;
Ro, ST .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (03) :232-242
[15]   Monitoring hydrofluorocarbon refrigerant leakage from air-conditioning systems in buildings [J].
Cheong, KW ;
Riffat, SB .
APPLIED ENERGY, 1996, 53 (04) :341-347
[16]  
Clodic D., 1996, IIF IIR CONF APPLICA
[17]  
Colboume D., 2003, P I REFR UK 2003 04, P1
[18]   Determination of optimum working conditions R22 and R404A refrigerant mixtures in heat-pumps using Taguchi method [J].
Comakli, K. ;
Simsek, F. ;
Comakli, O. ;
Sahin, B. .
APPLIED ENERGY, 2009, 86 (11) :2451-2458
[19]   Determination of optimum working conditions in heat-pumps using nonazeotropic refrigerant mixtures [J].
Çomakli, Ö ;
Çelik, C ;
Erdogan, S .
ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (02) :193-203
[20]  
Comakli Ö, 2010, ISI BILIM TEK DERG, V30, P113