Segmental Liver Stiffness Evaluated with Magnetic Resonance Elastography Is Responsive to Endovascular Intervention in Patients with Budd-Chiari Syndrome
被引:9
作者:
Xu, Peng
[1
]
Lyu, Lulu
[2
,3
]
Ge, Haitao
[1
]
Sami, Muhammad Umair
[1
]
Liu, Panpan
[1
]
Hu, Chunfeng
[1
]
Xu, Kai
[1
,3
]
机构:
[1] Xuzhou Med Univ, Affiliated Hosp, Dept Radiol, 99 Huaihai West Rd, Xuzhou 221002, Jiangsu, Peoples R China
[2] Xuzhou Cent Hosp, Dept CT & MRI, Xuzhou, Jiangsu, Peoples R China
[3] Nanjing Med Univ, Sch Clin Med 1, Nanjing, Jiangsu, Peoples R China
关键词:
Budd-Chiari syndrome;
Magnetic resonance elastography;
Liver stiffness;
Endovascular treatment;
MR ELASTOGRAPHY;
NONINVASIVE ASSESSMENT;
FIBROSIS;
DISEASE;
D O I:
10.3348/kjr.2018.0767
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Objective: To assess segmental liver stiffness (LS) with MRI before and after endovascular intervention in patients with Budd-Chiari syndrome (BCS). Materials and Methods: Twenty-three patients (13 males and 10 females; mean age, 42.6 +/- 12.6 years; age range, 31-56 years) with BCS as a primary liver disease were recruited for this study. Two consecutive magnetic resonance elastography (MRE) examinations were performed before the endovascular treatment. Fifteen patients who underwent endovascular intervention treatment also had follow-up MRE scans within three days after the procedure. LS was measured in three liver segments: the right posterior, right anterior, and left medial segments. Inter-reader and inter-exam repeatability were analyzed with intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Segmental LS and clinical characteristics before and after the intervention were also compared. Results: Within three days of the endovascular intervention, all three segmental LS values decreased: LS of the right posterior segment = 7.23 +/- 0.88 kPa (before) vs. 4.94 +/- 0.84 kPa (after), LS of the right anterior segment = 7.30 +/- 1.06 kPa (before) vs. 4.77 +/- 0.85 kPa (after), and LS of the left medial segment = 7.22 +/- 0.87 kPa (before) vs. 4.87 +/- 0.72 kPa (after) (all p = 0.001). There was a significant correlation between LS changes and venous pressure gradient changes before and after treatments (r = 0.651, p = 0.009). The clinical manifestations of all 15 patients significantly improved after therapy. The MRE repeatability was excellent, with insignificant variations (inter-reader, ICC = 0.839-0.943: inter-examination, ICC = 0.765-0.869). Bland-Altman analysis confirmed excellent agreement (limits of agreement, 13.4-19.4%). Conclusion: Segmental LS measured by MRE is a promising repeatable quantitative biomarker for monitoring the treatment response to minimally invasive endovascular intervention in patients with BCS.