Corrosion behaviour of porous Ti-39Nb alloy for biomedical applications

被引:101
作者
Fojt, Jaroslav [1 ]
Joska, Ludek [1 ]
Malek, Jaroslav [2 ]
机构
[1] Inst Chem Technol, Prague 16628, Czech Republic
[2] UJP Praha, Prague 15610, Czech Republic
关键词
Titanium; Alloy; Polarization; EIS; Crevice corrosion; FLUORIDE CONCENTRATION; CREVICE CORROSION; ELECTROCHEMICAL-BEHAVIOR; FEMORAL COMPONENTS; SURFACE-TREATMENT; TITANIUM-ALLOYS; NB ALLOYS; TI; RESISTANCE; PH;
D O I
10.1016/j.corsci.2013.03.007
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The presented work was aimed to describe the effect of porosity on the corrosion behaviour of Ti-39Nb alloy produced by the powder metallurgy technology, which represents a prospective material for medical applications. Corrosion properties of specimens with a porosity ranging from 0% to 33% were studied in simulated body environments, using electrochemical techniques and exposure tests. The results of measurements proved the occurrence of a localized form of corrosion in the material with a porosity of 24% and 33%. Distinct localization of the corrosion process was recorded in an environment containing fluoride ions. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:78 / 83
页数:6
相关论文
共 50 条
  • [31] Corrosion and biocompatibility behaviour of zirconia coating by EBPVD for biomedical applications
    Kaliaraj, Gobi Saravanan
    Vishwakarma, Vinita
    Kirubaharan, Kamalan
    Dharini, T.
    Ramachandran, D.
    Muthaiah, Bavanilatha
    SURFACE & COATINGS TECHNOLOGY, 2018, 334 : 336 - 343
  • [32] Properties of Porous Ti-26Nb-6Mo-1.5Sn Alloy Produced via Powder Metallurgy for Biomedical Applications
    Dercz, G.
    Matula, I.
    Maszybrocka, J.
    PHYSICS OF METALS AND METALLOGRAPHY, 2019, 120 (13) : 1384 - 1391
  • [33] Preparation and Mechanical Properties of Porous Ti-10 Mo Alloy for Biomedical Applications
    Zhi Lingling
    Lu Xin
    Meng Qingyu
    Xu Wei
    Qu Xuanhui
    RARE METAL MATERIALS AND ENGINEERING, 2016, 45 (06) : 1554 - 1558
  • [34] Corrosion resistance of aged Ti-Mo-Nb alloys for biomedical applications
    de Almeida, L. H.
    Bastos, I. N.
    Santos, I. D.
    Dutra, A. J. B.
    Nunes, C. A.
    Gabriel, S. B.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2014, 615 : S666 - S669
  • [35] Investigations into Ti-(Nb,Ta)-Fe alloys for biomedical applications
    Biesiekierski, Arne
    Lin, Jixing
    Li, Yuncang
    Ping, Dehai
    Yamabe-Mitarai, Yoko
    Wen, Cuie
    ACTA BIOMATERIALIA, 2016, 32 : 336 - 347
  • [36] Enhanced structural and tribological performance of nanostructured Ti-15Nb alloy for biomedical applications
    Fellah, Mamoun
    Hezil, Naouel
    Touhami, Mohamed Zine
    Obrosov, Aleksei
    Weiss, Sabine
    Kashkarov, Egor B.
    Lider, Andrey M.
    Montagne, Alex
    Iost, Alain
    RESULTS IN PHYSICS, 2019, 15
  • [37] Corrosion behaviour of Ti40Cu60 alloy in H3PO4 solutions
    Bouchemel, H.
    Benchettara, A.
    MATERIALS CHEMISTRY AND PHYSICS, 2009, 115 (2-3) : 572 - 577
  • [38] Anisotropic microstructure, nanomechanical and corrosion behavior of direct energy deposited Ti-13Nb-13Zr biomedical alloy
    Ansari, Nooruddin
    Lee, Dong-Hyun
    Huang, E-Wen
    Jain, Jayant
    Lee, Soo Yeol
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2023, 26 : 2682 - 2694
  • [39] Characteristics of Ti-Nb-Mg alloy by powder metallurgy for biomedical applications
    Li, Zhongjie
    Xu, Hao
    Dong, Anping
    Qiu, Jiajun
    He, Lin
    Zhang, Ting
    Du, Dafan
    Xing, Hui
    Zhu, Guoliang
    Wang, Donghong
    Sun, Baode
    MATERIALS CHARACTERIZATION, 2021, 173
  • [40] Impact of ruthenium on microstructure and corrosion behavior of β-type Ti-Nb-Ru alloys for biomedical applications
    Biesiekierski, Arne
    Ping, D. H.
    Yamabe-Mitarai, Y.
    Wen, Cuie
    MATERIALS & DESIGN, 2014, 59 : 303 - 309