Ultrasensitive label-free optical microfiber coupler biosensor for detection of cardiac troponin I based on interference turning point effect

被引:123
作者
Zhou, Wenchao [1 ]
Li, Kaiwei [2 ]
Wei, Youlian [1 ,3 ]
Hao, Peng [1 ]
Chi, Mingbo [1 ]
Liu, Yongshun [1 ]
Wu, Yihui [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, State Key Lab Appl Opt, Changchun 130033, Jilin, Peoples R China
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[3] Univ Chinese Acad Sci, Beijing 100039, Peoples R China
关键词
Optical microfiber coupler; Biosensor; Dispersion turning point; Cardiac troponin I; Ultrasensitivity; Regeneration; ACUTE MYOCARDIAL-INFARCTION; REFRACTIVE-INDEX INCREMENTS; ELECTROCHEMICAL IMMUNOSENSOR; IMMUNOASSAY; BIOMARKERS; NANOPARTICLES; DIAGNOSIS; COMPLEX; SILICON; ARRAYS;
D O I
10.1016/j.bios.2018.01.061
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Sensitive detection of cardiac biomarkers is critical for clinical diagnostics of myocardial infarction (MI) while such detection is quite challenging due to the ultra-low concentration of cardiac biomarkers. In this work, a label-free immunosensor based on optical microfiber coupler (OMC) has been developed for the ultrasensitive detection of cardiac troponin I (cTnI), a selective and highly sensitive biomarker of acute myocardial infarction (AMI). CTnI monoclonal antibodies were immobilized on the surface of the fiber through polyelectrolyte layer using layer-by-layer deposition technique. For refractive index sensing characterization, an ultra-high sensitivity of 91777.9 nm/RIU was achieved when the OMC works around the dispersion turning point, which is the highest experimental demonstration in the field of fiber-optic evanescent biosensors. For biosensing, the immunosensor with good specificity showed a linear wavelength shift in the range of 2-10 fg/mL and an ultra-low detection limit of 2 fg/mL. Such immunosensors have huge application potential for the detection of cardiac biomarkers of myocardial infarction due to simple detection scheme, quick response time, ease of handling and miniaturation.
引用
收藏
页码:99 / 104
页数:6
相关论文
共 47 条
[1]   Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor [J].
Akter, Rashida ;
Jeong, Bongjin ;
Lee, Yong-Mi ;
Choi, Jong-Soon ;
Rahman, Md. Aminur .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :637-643
[2]   A highly sensitive quartz crystal microbalance immunosensor based on magnetic bead-supported bienzymes catalyzed mass enhancement strategy [J].
Akter, Rashida ;
Rhee, Choong Kyun ;
Rahman, Md. Aminur .
BIOSENSORS & BIOELECTRONICS, 2015, 66 :539-546
[3]  
[Anonymous], ANAL CHARACTERISTICS
[4]  
Ball V, 1998, BIOPOLYMERS, V46, P489
[5]   Protein attachment to silane-functionalized porous silicon: A comparison of electrostatic and covalent attachment [J].
Baranowska, Malgorzata ;
Slota, Agata J. ;
Eravuchira, Pinkie J. ;
Alba, Maria ;
Formentin, Pilar ;
Pallares, Josep ;
Ferre-Borrull, Josep ;
Marsal, Lluis F. .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2015, 452 :180-189
[6]  
BODOR GS, 1992, CLIN CHEM, V38, P2203
[7]   A NEW IMMUNOASSAY FOR THE MEASUREMENT OF MYOGLOBIN IN SERUM [J].
CARRARO, P ;
PLEBANI, M ;
VARAGNOLO, MC ;
ZANINOTTO, M ;
ROSSETTI, M ;
BURLINA, A .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1994, 8 (02) :70-75
[8]   Towards sensitive label-free immunosensing by means of turn-around point long period fiber gratings [J].
Chiavaioli, F. ;
Biswas, P. ;
Trono, C. ;
Bandyopadhyay, S. ;
Giannetti, A. ;
Tombelli, S. ;
Basumallick, N. ;
Dasgupta, K. ;
Baldini, F. .
BIOSENSORS & BIOELECTRONICS, 2014, 60 :305-310
[9]   Ultrasensitive, label-free detection of cardiac biomarkers with optical SIS sensor [J].
Diware, Mangesh S. ;
Cho, Hyun Mo ;
Chegal, Won ;
Cho, Yong Jai ;
Kim, Dong Soo ;
Won O, Sang ;
Kim, Kyeong-Suk ;
Paek, Se-Hwan .
BIOSENSORS & BIOELECTRONICS, 2017, 87 :242-248
[10]   Diagnostics on acute myocardial infarction: Cardiac troponin biomarkers [J].
Fathil, M. F. M. ;
Arshad, M. K. Md ;
Gopinath, Subash C. B. ;
Hashim, U. ;
Adzhri, R. ;
Ayub, R. M. ;
Ruslinda, A. R. ;
Nuzaihan, M. M. N. ;
Azman, A. H. ;
Zaki, M. ;
Tang, Thean-Hock .
BIOSENSORS & BIOELECTRONICS, 2015, 70 :209-220