Determination of Benzoyl Peroxide in Flour Brightener with Microfluidic Chip-Based Flow-Injection Chemiluminescence

被引:6
|
作者
Wang, Xiaozhang [1 ]
Wang, Chaohui [1 ]
Zhang, Qunming [1 ]
Wang, Jing [1 ]
Zheng, Tengfei [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Mech Engn, Xian 710049, Peoples R China
关键词
Microfluidic chip; Chemiluminescence; Flow injecting; Benzoyl peroxide; SYSTEM;
D O I
10.14233/ajchem.2013.13248
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Benzoyl peroxide (BPO) in flour brightener was determined with chip-based chemiluminescence reaction. The microfluidic chip was fabricated with PDMS using MEMS techniques and the flow-injection chemiluminescence experiments were performed. The conditions of experiments including sample inject and flow-rate were selected and optimized according to their different influences on detect results. The standard curve of relative chemiluminescence intensity and benzoyl peroxide concentration was constructed from the reaction of benzoyl peroxide and luminol solutions with specific concentration, respectively. The experimental results indicate that a good linear relation is formed between the chemiluminescence intensity and benzoyl peroxide concentration within 10(-6)-10(-8) g mL(-1). The detection limit is about 2 x 10(-9) g mL(-1) in benzoyl peroxide solution. At last, flour brightener samples bought from market were tested with this microfluidic chip system. The result was consistent well with the content of brightener tag. Some important topics of integrated chip were discussed including inject pump, active mixer and rnicroheater.
引用
收藏
页码:1942 / 1946
页数:5
相关论文
共 50 条
  • [41] FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF COBALT(II) AND MANGANESE(II)
    LIN, QX
    GUIRAUM, A
    ESCOBAR, R
    DELAROSA, FF
    ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 379 - 385
  • [42] Determination of trace amounts of sulfide by flow-injection chemiluminescence method
    Du, JX
    Li, YH
    Lü, JR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (02) : 189 - 191
  • [43] CHEMILUMINESCENCE DETERMINATION OF PROTEASES BY FLOW-INJECTION USING IMMOBILIZED ISOLUMINOL
    EDWARDS, R
    TOWNSHEND, A
    STODDART, B
    ANALYST, 1995, 120 (01) : 117 - 120
  • [44] A new flow-injection chemiluminescence method for the determination of acyclovir and gancyclovir
    Wang, NN
    Tang, YH
    Xiong, XY
    Han, XN
    Yu, CL
    ANALYTICAL LETTERS, 2006, 39 (05) : 973 - 983
  • [45] FLOW-INJECTION CHEMILUMINESCENCE METHOD FOR THE SELECTIVE DETERMINATION OF CHROMIUM(III)
    ESCOBAR, R
    LIN, QX
    GUIRAUM, A
    DELAROSA, FF
    ANALYST, 1993, 118 (06) : 643 - 647
  • [46] Selective determination of human immunoglobulin G by flow-injection chemiluminescence
    Zhou, Min
    Wang, Jiuchun
    Ma, Yongjun
    Fang, Yanjun
    Chen, Junhui
    Chen, Hui
    LUMINESCENCE, 2011, 26 (02) : 142 - 147
  • [47] Microfluidic chip-based flow injection system for gas diffusion separation with an evaporation pump drive
    Jia, Hong-Xin
    Wang, Shi-Li
    Guan, Yan-Xia
    Fang, Zhao-Lun
    PROCEEDINGS OF THE FIRST SHENYANG INTERNATIONAL COLLOQUIUM ON MICROFLUIDICS, 2007, : 90 - 91
  • [48] Flow-injection determination of trace amounts of dopamine by chemiluminescence detection
    Zhang, LH
    Teshima, N
    Hasebe, T
    Kurihara, M
    Kawashima, T
    TALANTA, 1999, 50 (03) : 677 - 683
  • [49] The determination of perphenazine by a new simple flow-injection chemiluminescence method
    Han, XN
    Tang, YH
    Yu, CL
    Zheng, XH
    Jin, QJ
    ANALYTICAL LETTERS, 2005, 38 (12) : 1933 - 1941
  • [50] Flow-injection Chemiluminescence Determination of Trace Calf Thymus DNA
    Min ZHOU
    Chinese Chemical Letters, 2003, (10) : 1051 - 1053