Penalized Likelihood PET Image Reconstruction Using Patch-Based Edge-Preserving Regularization

被引:126
作者
Wang, Guobao [1 ]
Qi, Jinyi [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
关键词
Image reconstruction; patch regularization; penalized maximum likelihood; positron emission tomography; NONLOCAL REGULARIZATION; RESTORATION; ALGORITHMS;
D O I
10.1109/TMI.2012.2211378
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Iterative image reconstruction for positron emission tomography (PET) can improve image quality by using spatial regularization that penalizes image intensity difference between neighboring pixels. The most commonly used quadratic penalty often oversmoothes edges and fine features in reconstructed images. Nonquadratic penalties can preserve edges but often introduce piece-wise constant blocky artifacts and the results are also sensitive to the hyper-parameter that controls the shape of the penalty function. This paper presents a patch-based regularization for iterative image reconstruction that uses neighborhood patches instead of individual pixels in computing the nonquadratic penalty. The new regularization is more robust than the conventional pixel-based regularization in differentiating sharp edges from random fluctuations due to noise. An optimization transfer algorithm is developed for the penalized maximum likelihood estimation. Each iteration of the algorithm can be implemented in three simple steps: an EM-like image update, an image smoothing and a pixel-by-pixel image fusion. Computer simulations show that the proposed patch-based regularization can achieve higher contrast recovery for small objects without increasing background variation compared with the quadratic regularization. The reconstruction is also more robust to the hyper-parameter than conventional pixel-based nonquadratic regularizations. The proposed regularization method has been applied to real 3-D PET data.
引用
收藏
页码:2194 / 2204
页数:11
相关论文
共 41 条
[1]   Reconstruction of 3D Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using Nonlocal Means [J].
Adluru, Ganesh ;
Tasdizen, Tolga ;
Schabel, Matthias C. ;
DiBella, Edward V. R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (05) :1217-1227
[2]   Bayesian image reconstruction for emission tomography based on median root prior [J].
Alenius, S ;
Ruotsalainen, U .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (03) :258-265
[3]  
Bouman C., 2002, IEEE T IMAGE PROCESS, V2, P296
[4]  
Boyd S., 2004, CONVEX OPTIMIZATION, VFirst, DOI DOI 10.1017/CBO9780511804441
[5]   A review of image denoising algorithms, with a new one [J].
Buades, A ;
Coll, B ;
Morel, JM .
MULTISCALE MODELING & SIMULATION, 2005, 4 (02) :490-530
[6]  
Buades A., 2006, IMAGE E ENHANCEMENT
[7]   SENSOR FUSION IN IMAGE-RECONSTRUCTION [J].
CHEN, CT ;
OUYANG, XL ;
WONG, WH ;
HU, XP ;
JOHNSON, VE ;
ORDONEZ, C ;
METZ, CE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :687-692
[8]   Nonlocal prior Bayesian tomographic reconstruction [J].
Chen, Yang ;
Ma, Jianhua ;
Feng, Qianjin ;
Luo, Limin ;
Shi, Pengcheng ;
Chen, Wufan .
JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2008, 30 (02) :133-146
[9]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[10]   A MODIFIED EXPECTATION MAXIMIZATION ALGORITHM FOR PENALIZED LIKELIHOOD ESTIMATION IN EMISSION TOMOGRAPHY [J].
DEPIERRO, AR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (01) :132-137