Outcome and Complications After Implantable Cardioverter Defibrillator Therapy in Hypertrophic Cardiomyopathy Systematic Review and Meta-Analysis

被引:129
作者
Schinkel, Arend F. L. [1 ,2 ]
Vriesendorp, Pieter A. [1 ]
Sijbrands, Eric J. G. [2 ]
Jordaens, Luc J. L. M. [1 ]
ten Cate, Folkert J. [1 ]
Michels, Michelle [1 ]
机构
[1] Erasmus MC, Dept Cardiol, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[2] Erasmus MC, Dept Internal Med, Sect Pharmacol Vasc & Metab Dis, NL-3015 CE Rotterdam, Netherlands
关键词
hypertrophic cardiomyopathy; implantable cardioverter defibrillator; sudden cardiac death; prognosis; complications; SUDDEN CARDIAC DEATH; HIGH-RISK PATIENTS; TERM-FOLLOW-UP; VENTRICULAR TACHYARRHYTHMIAS; PREVENTION; INTERVENTIONS; EFFICACY; DISCHARGES; PATTERNS; SURVIVAL;
D O I
10.1161/CIRCHEARTFAILURE.112.969626
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Previous observational studies demonstrated that patients with hypertrophic cardiomyopathy at risk for sudden cardiac death (SCD) may benefit from implantable cardioverter defibrillator (ICD) therapy. A complete overview of outcome and complications after ICD therapy is currently not available. This study pools data from published studies on outcome and complications after ICD therapy in patients with hypertrophic cardiomyopathy. Methods and Results-A PubMed database search returned 27 studies on 16 cohorts reporting outcome and complications after ICD therapy in patients with hypertrophic cardiomyopathy. In case of >1 publications on a particular cohort, the publication with the largest number of patients was included in the meta-analysis. ICD interventions, complications, and mortality rates were extracted, pooled, and analyzed. There were 2190 patients (mean age, 42 years; 38% women), most of whom (83%) received an ICD for primary prevention of SCD. Risk factors for SCD were left ventricular wall thickness >= 30 mm (20%), family history of SCD (43%), nonsustained ventricular tachycardia (46%), syncope (41%), and abnormal blood pressure response (25%). During the 3.7-year follow-up, the annualized cardiac mortality rate was 0.6%, the noncardiac mortality rate was 0.4%, and the appropriate ICD intervention rate was 3.3%. The annualized inappropriate ICD intervention rate was 4.8% and the annualized ICD-related complication rate was 3.4%. Conclusions-This meta-analysis demonstrates a low cardiac and noncardiac mortality rate after ICD therapy in patients with hypertrophic cardiomyopathy. Appropriate ICD intervention occurred at a rate of 3.3%/year, thereby, most probably, preventing SCD. Inappropriate ICD intervention and complications are not uncommon. (Circ Heart Fail. 2012;5:552-559.)
引用
收藏
页码:552 / 559
页数:8
相关论文
共 35 条
[21]   Efficacy of implantable cardioverter-defibrillators for the prevention of sudden death in patients with hypertrophic cardiomyopathy. [J].
Maron, BJ ;
Shen, WK ;
Link, MS ;
Epstein, AE ;
Almquist, AK ;
Daubert, JP ;
Bardy, GH ;
Favale, S ;
Rea, RF ;
Boriani, G ;
Estes, NAM ;
Spirito, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (06) :365-373
[22]   Surgical septal myectomy decreases the risk for appropriate implantable cardioverter defibrillator discharge in obstructive hypertrophic cardiomyopathy [J].
McLeod, Christopher J. ;
Ommen, Steve R. ;
Ackerman, Michael J. ;
Weivoda, Peggy L. ;
Shen, Win K. ;
Dearani, Joseph A. ;
Schaff, Hartzell V. ;
Tajik, A. Jamil ;
Gersh, Bernard J. .
EUROPEAN HEART JOURNAL, 2007, 28 (21) :2583-2588
[23]  
Medeiros Paulo de Tarso Jorge, 2006, Arq. Bras. Cardiol., V87, P649, DOI 10.1590/S0066-782X2006001800016
[24]   Meta-analyses and Forest plots using a microsoft excel spreadsheet: Step-by-step guide focusing on descriptive data analysis [J].
Jeruza L Neyeloff ;
Sandra C Fuchs ;
Leila B Moreira .
BMC Research Notes, 5 (1)
[25]   The long-term survival and the risks and benefits of implantable cardioverter defibrillators in patients with hypertrophic cardiomyopathy [J].
O'Mahony, Constantinos ;
Lambiase, Pier D. ;
Quarta, Giovanni ;
Cardona, Montserrat ;
Calcagnino, Margherita ;
Tsovolas, Konstantinos ;
Al-Shaikh, Shereen ;
Rahman, Shafiqur M. ;
Arnous, Samer ;
Jones, Sue ;
McKenna, William ;
Elliott, Perry .
HEART, 2012, 98 (02) :116-125
[26]   Gender Differences in Procedure-Related Adverse Events in Patients Receiving Implantable Cardioverter-Defibrillator Therapy [J].
Peterson, Pamela N. ;
Daugherty, Stacie L. ;
Wang, Yongfei ;
Vidaillet, Humberto J. ;
Heidenreich, Paul A. ;
Curtis, Jeptha P. ;
Masoudi, Frederick A. .
CIRCULATION, 2009, 119 (08) :1078-U30
[27]   Hypertrophic cardiomyopathy: Role of the implantable cardioverter-defibrillator [J].
Primo, J ;
Geelen, P ;
Brugada, J ;
Lorga, A ;
Mont, L ;
Wellens, F ;
Valentino, M ;
Brugada, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (05) :1081-1085
[28]   Incidence of adequate ICD interventions in patients with hypertrophic cardiomyopathy supposed to be at high risk for sudden cardiac death [J].
Prinz, Christian ;
Vogt, Juergen ;
Bitter, Thomas ;
Muntean, Bogdan G. ;
Hering, Detlef ;
Horstkotte, Dieter ;
Faber, Lothar .
ACTA CARDIOLOGICA, 2010, 65 (05) :521-525
[29]  
Przybylski A, 2005, KARDIOL POL, V63, P398
[30]  