Internal anterior fixators for pelvic ring injuries: Do monaxial pedicle screws provide more stiffness than polyaxial pedicle screws?

被引:28
作者
Eagan, Michael [1 ]
Kim, Hyunchul [2 ]
Manson, Theodore T. [1 ]
Gary, Joshua L. [3 ]
Russell, Joseph P. [2 ]
Hsieh, Adam H. [2 ]
O'Toole, Robert V. [1 ]
Boulton, Christina L. [1 ]
机构
[1] Univ Maryland, Med Ctr, Dept Orthopaed, R Adams Cowley Shock Trauma Ctr, Baltimore, MD 21201 USA
[2] Univ Maryland, Orthopaed Mechanobiol Lab, Fischell Dept Bioengn, College Pk, MD 20742 USA
[3] Univ Texas Hlth Sci Ctr Houston, Dept Orthopaed Surg, Houston, TX 77030 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷 / 06期
关键词
Internal anterior fixator; INFIX; Pelvic ring injury; Monaxial screws; Polyaxial screws; EXTERNAL FIXATION; FRACTURES; MANAGEMENT; REDUCTION;
D O I
10.1016/j.injury.2015.01.040
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Little is known about the mechanical properties of internal anterior fixators (known as INFIX), which have been proposed as subcutaneous alternatives to traditional anterior external fixators for pelvic ring disruptions. We hypothesised that INFIX has superior biomechanical performance compared with traditional external fixators because the distance from the bar to the bone is reduced. Methods: Using a commercially available synthetic bone model, 15 unstable pelvic ring injuries were simulated by excising the pubic bone through the bilateral superior and inferior rami anteriorly and the sacrum through the bilateral sacral foramen posteriorly. Three test groups were established: (1) traditional supra-acetabular external fixation, (2) INFIX with polyaxial screws, (3) INFIX with monaxial screws. Load was applied, simulating lateral compression force. Outcome measure was construct stiffness. Results: The traditional external fixator constructs had an average stiffness of 6.21 N/mm +/- 0.40 stanstandard deviation (SD). INFIX with monaxial screws was 23% stiffer than the traditional external fixator (mean stiffness, 7.66 N/mm +/- 0.86 SD; p = .01). INFIX with polyaxial screws was 26% less stiff than INFIX with monaxial screws (mean stiffness, 5.69 N/mm +/- 1.24 SD; p = .05). No significant difference was noted between polyaxial INFIX and external fixators (mean stiffness, 6.21 N/mm +/- 0.40 SD; p = .65). Conclusions: The performance of INFIX depends on the type of screw used, with monaxial screws providing significantly more stiffness than polyaxial screws. Despite the mechanical advantage of being closer to the bone, polyaxial INFIX was not stiffer than traditional external fixation. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:996 / 1000
页数:5
相关论文
共 16 条
[1]   The pelvic external fixation: the mid-term results of 41 patients treated with a newly designed fixator [J].
Arazi, M ;
Kutlu, A ;
Mutlu, M ;
Yel, M ;
Kapiciglu, MIS .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2000, 120 (10) :584-586
[2]  
Bellabarba Carlo, 2006, J Orthop Trauma, V20, pS7
[3]   Anterior Pelvic External Fixator Versus Subcutaneous Internal Fixator in the Treatment of Anterior Ring Pelvic Fractures [J].
Cole, Peter A. ;
Gauger, Erich M. ;
Anavian, Jack ;
Ly, Thuan V. ;
Morgan, Robert A. ;
Heddings, Archie A. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (05) :269-277
[4]   Anterior Pelvic Reduction and Fixation Using a Subcutaneous Internal Fixator [J].
Gardner, Michael J. ;
Mehta, Samir ;
Mirza, Amer ;
Ricci, William M. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (05) :314-321
[5]   Placement of half-pins for supra-acetabular external fixation: An anatomic study [J].
Haidukewych, GJ ;
Kumar, S ;
Prpa, B .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (411) :269-273
[6]  
KELLAM JF, 1989, CLIN ORTHOP RELAT R, P66
[7]   Effect of pin location on stability of pelvic external fixation [J].
Kim, WY ;
Hearn, TC ;
Seleem, O ;
Mahalingam, E ;
Stephen, D ;
Tile, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (361) :237-244
[8]   Failure of reduction with an external fixator in the management of injuries of the pelvic ring -: Long-term evaluation of 110 patients [J].
Lindahl, J ;
Hirvensalo, E ;
Böstman, O ;
Santavirta, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (06) :955-962
[9]   Complications of temporary and definitive external fixation of pelvic ring injuries [J].
Mason, WTM ;
Khan, SN ;
James, CL ;
Chesser, TJS ;
Ward, AJ .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (05) :599-604
[10]   Anterior Pelvic Subcutaneous Internal Fixator Application: An Anatomic Study [J].
Moazzam, Caroline ;
Heddings, Archie A. ;
Moodie, Patrick ;
Cole, Peter A. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (05) :263-268