Thyroid dose assessments due to inhalation of 131I for nuclear medicine workers

被引:2
作者
Liu, Gang [1 ]
Li, Ye [1 ]
Zhang, HanYu [1 ]
Zhang, Xue [1 ]
Liu, Yin Yin [1 ]
Wu, Xiao Qin [1 ]
Niu, Li Mei [1 ]
Zhang, Rong [1 ]
机构
[1] Chinese Acad Med Sci, Joint Lab Inst Radiol, Gansu Prov Ctr Dis Control & Prevent, Lanzhou, Peoples R China
关键词
I-131; thyroid; radiation protection; internal doses; nuclear medicine; BODY;
D O I
10.3389/fpubh.2022.1027782
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
BackgroundIn general, medical staff who work in nuclear medicine should be entirely safe in their professional environment. Nevertheless, we already know that the working environment of the nuclear medicine staff is not completely safe due to the handling of high amounts of radionuclides for diagnostic and therapy applications, which is especially relevant for I-131 (as a non-sealed source). PurposeThe goal of this study was to assess the inhaled I-131 thyroid dose in nuclear medicine workers and to introduce a simple method for internal exposure monitoring. MethodsUsing 2-IN*2-in NaI (Tl) scintillation spectrometer and its supporting software (InSpector Maintenance Utility and Genie 2000), from 2019 to 2021, internal thyroid irradiation monitoring, an internal thyroid irradiation monitoring investi A NaI (Tl) scintillation spectrometer and its sugation was carried out for 3 consecutive years, between 2019 and 2021, in staff members of nuclear medicine departments engaged with iodine therapy. Results(131)I activity was found highest in the thyroid of nuclear medicine workers involved with the manual packaging and delivery of the radioisotope, while it was not detected in staff members involved with the automatic packaging and drug delivery. The activity range was found to be 30.00 +/- 6.60-6070.00 +/- 1335.40 Bq for the exposed personnel, and the estimated dose was 0.05-6.77 mSv. In 2021, three workers had an annual equivalent dose above 5 mSv. ConclusionBy monitoring the thyroid I-131 in staff members of the nuclear medicine department, it was found that there are I-131 internal occupational exposure risks. The best solution is automatic packaging and drug delivery.
引用
收藏
页数:13
相关论文
共 19 条
[1]  
American National Standard Institute, N4431973 ANSI
[2]  
[Anonymous], 1994, Ann ICRP, V24, P1
[3]  
[Anonymous], 1292016 GBZ
[4]  
[Anonymous], 1997, ANN ICRP, V27, P1
[5]  
[Anonymous], GBZ15161282019
[6]  
[Anonymous], 2007, The Recommendations of the International Commission on Radiological Protection, V103, DOI DOI 10.1016/J.ICRP.2007.10.003
[7]  
[Anonymous], 2014, Official Journal of the European Union, P57
[8]   Measurement of 131I activity in thyroid of nuclear medical staff and internal dose assessment in a Polish nuclear medical hospital [J].
Brudecki, K. ;
Kowalska, A. ;
Zagrodzki, P. ;
Szczodry, A. ;
Mroz, T. ;
Janowski, P. ;
Mietelski, J. W. .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2017, 56 (01) :19-26
[9]  
王松, 2020, [中国实用外科杂志, Chinese Journal of Practical Surgery], V40, P747
[10]  
European Commission Unit H.4-Radiation Protection, 2008, 154 EUR COMM