Planning Hybrid Intensity Modulated Radiation Therapy for Whole-breast Irradiation

被引:28
|
作者
Farace, Paolo [1 ]
Zucca, Sergio [1 ]
Solla, Ignazio [1 ]
Fadda, Giuseppina [1 ]
Durzu, Silvia [1 ]
Porru, Sergio [1 ]
Meleddu, Gianfranco [1 ]
Deidda, Maria Assunta [2 ]
Possanzini, Marco [2 ]
Orru, Sivia [2 ]
Lay, Giancarlo [2 ]
机构
[1] Reg Oncol Hosp, Dept Med Phys, I-09121 Cagliari, Italy
[2] Reg Oncol Hosp, Radiotherapy Dept, I-09121 Cagliari, Italy
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2012年 / 84卷 / 01期
关键词
RANDOMIZED-TRIAL; CANCER; RADIOTHERAPY; IMRT; STANDARD; VOLUME;
D O I
10.1016/j.ijrobp.2012.02.025
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To test tangential and not-tangential hybrid intensity modulated radiation therapy (IMRT) for whole-breast irradiation. Methods and Materials: Seventy-eight (36 right-, 42 left-) breast patients were randomly selected. Hybrid IMRT was performed by direct aperture optimization. A semiautomated method for planning hybrid IMRT was implemented using Pinnacle scripts. A plan optimization volume (POV), defined as the portion of the planning target volume covered by the open beams, was used as the target objective during inverse planning. Treatment goals were to prescribe a minimum dose of 47.5 Gy to greater than 90% of the POV and to minimize the POV and/or normal tissue receiving a dose greater than 107%. When treatment goals were not achieved by using a 4-field technique (2 conventional open plus 2 IMRT tangents), a 6-field technique was applied, adding 2 non tangential (anterior-oblique) IMRT beams. Results: Using scripts, manual procedures were minimized (choice of optimal beam angle, setting monitor units for open tangentials, and POV definition). Treatment goals were achieved by using the 4-field technique in 61 of 78 (78%) patients. The 6-field technique was applied in the remaining 17 of 78 (22%) patients, allowing for significantly better achievement of goals, at the expense of an increase of low-dose (similar to 5 Gy) distribution in the contralateral tissue, heart, and lungs but with no significant increase of higher doses (similar to 20 Gy) in heart and lungs. The mean monitor unit contribution to IMRT beams was significantly greater (18.7% vs 9.9%) in the group of patients who required 6-field procedure. Conclusions: Because hybrid IMRT can be performed semiautomatically, it can be planned for a large number of patients with little impact on human or departmental resources, promoting it as the standard practice for whole-breast irradiation. (C) 2012 Elsevier Inc.
引用
收藏
页码:E115 / E122
页数:8
相关论文
共 50 条
  • [41] Quantitative Assessment of Breast Cosmetic Outcome After Whole-Breast Irradiation
    Reddy, Jay P.
    Lei, Xiudong
    Huang, Sheng-Cheng
    Nicklaus, Krista M.
    Fingeret, Michelle C.
    Shaitelman, Simona F.
    Hunt, Kelly K.
    Buchholz, Thomas A.
    Merchant, Fatima
    Markey, Mia K.
    Smith, Benjamin D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 97 (05): : 894 - 902
  • [42] BENEFIT OF RADIATION BOOST AFTER WHOLE-BREAST RADIOTHERAPY
    Livi, Lorenzo
    Borghesi, Simona
    Saieva, Calogero
    Fambrini, Massimiliano
    Iannalfi, Alberto
    Greto, Daniela
    Paiar, Fabiola
    Scoccianti, Silvia
    Simontacchi, Gabriele
    Bianchi, Simonetta
    Cataliotti, Luigi
    Biti, Giampaolo
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (04): : 1029 - 1034
  • [43] TREATMENT WITH INTENSITY - MODULATED RADIATION THERAPY (IMRT) FOR BREAST CANCER
    不详
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2014, 60 (06): : 508 - 511
  • [44] Performance of a knowledge-based planning model for optimizing intensity-modulated radiotherapy plans for partial breast irradiation
    Frederick, Amy
    Roumeliotis, Michael
    Grendarova, Petra
    Quirk, Sarah
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (03):
  • [45] Feasibility of using nonflat photon beams for whole-breast irradiation with breath hold
    Wang, Yuenan
    Vassil, Andrew
    Tendulkar, Rahul
    Bayouth, John
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 57 - 64
  • [46] Tangent field technique of TomoDirect improves dose distribution for whole-breast irradiation
    Hashimoto, Harumitsu
    Omura, Motoko
    Matsui, Kengo
    Mukai, Yuki
    Hongo, Hideyuki
    Yamakabe, Wataru
    Saito, Kaori
    Yoshida, Miwa
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 225 - 232
  • [47] Intensity modulated radiation therapy with simultaneous integrated boost in early breast cancer irradiation. Report of feasibility and preliminary toxicity
    Fiorentino, A.
    Mazzola, R.
    Ricchetti, F.
    Levra, N. Giaj
    Fersino, S.
    Naccarato, S.
    Sicignano, G.
    Ruggieri, R.
    Di Paola, G.
    Massocco, A.
    Gori, S.
    Alongi, F.
    CANCER RADIOTHERAPIE, 2015, 19 (05): : 289 - 294
  • [48] A Script-Based Automatic Intensity Modulated Radiation Therapy Planning Method With Robust Optimization for Craniospinal Irradiation
    Wang, Xuetao
    Li, Changhu
    Li, Guangjun
    Zhao, Jianling
    Bai, Sen
    PRACTICAL RADIATION ONCOLOGY, 2023, 13 (02) : e209 - e215
  • [49] Automation and Intensity Modulated Radiation Therapy for Individualized High-Quality Tangent Breast Treatment Plans
    Purdie, Thomas G.
    Dinniwell, Robert E.
    Fyles, Anthony
    Sharpe, Michael B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 (03): : 688 - 695
  • [50] Decrease of the lumpectomy cavity volume after whole-breast irradiation affects small field boost planning
    Mohiuddin, Majid M.
    Nichols, Elizabeth M.
    Marter, Kimberley J.
    Flannery, Todd W.
    MEDICAL DOSIMETRY, 2012, 37 (03) : 339 - 343