Planning Hybrid Intensity Modulated Radiation Therapy for Whole-breast Irradiation

被引:28
|
作者
Farace, Paolo [1 ]
Zucca, Sergio [1 ]
Solla, Ignazio [1 ]
Fadda, Giuseppina [1 ]
Durzu, Silvia [1 ]
Porru, Sergio [1 ]
Meleddu, Gianfranco [1 ]
Deidda, Maria Assunta [2 ]
Possanzini, Marco [2 ]
Orru, Sivia [2 ]
Lay, Giancarlo [2 ]
机构
[1] Reg Oncol Hosp, Dept Med Phys, I-09121 Cagliari, Italy
[2] Reg Oncol Hosp, Radiotherapy Dept, I-09121 Cagliari, Italy
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2012年 / 84卷 / 01期
关键词
RANDOMIZED-TRIAL; CANCER; RADIOTHERAPY; IMRT; STANDARD; VOLUME;
D O I
10.1016/j.ijrobp.2012.02.025
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To test tangential and not-tangential hybrid intensity modulated radiation therapy (IMRT) for whole-breast irradiation. Methods and Materials: Seventy-eight (36 right-, 42 left-) breast patients were randomly selected. Hybrid IMRT was performed by direct aperture optimization. A semiautomated method for planning hybrid IMRT was implemented using Pinnacle scripts. A plan optimization volume (POV), defined as the portion of the planning target volume covered by the open beams, was used as the target objective during inverse planning. Treatment goals were to prescribe a minimum dose of 47.5 Gy to greater than 90% of the POV and to minimize the POV and/or normal tissue receiving a dose greater than 107%. When treatment goals were not achieved by using a 4-field technique (2 conventional open plus 2 IMRT tangents), a 6-field technique was applied, adding 2 non tangential (anterior-oblique) IMRT beams. Results: Using scripts, manual procedures were minimized (choice of optimal beam angle, setting monitor units for open tangentials, and POV definition). Treatment goals were achieved by using the 4-field technique in 61 of 78 (78%) patients. The 6-field technique was applied in the remaining 17 of 78 (22%) patients, allowing for significantly better achievement of goals, at the expense of an increase of low-dose (similar to 5 Gy) distribution in the contralateral tissue, heart, and lungs but with no significant increase of higher doses (similar to 20 Gy) in heart and lungs. The mean monitor unit contribution to IMRT beams was significantly greater (18.7% vs 9.9%) in the group of patients who required 6-field procedure. Conclusions: Because hybrid IMRT can be performed semiautomatically, it can be planned for a large number of patients with little impact on human or departmental resources, promoting it as the standard practice for whole-breast irradiation. (C) 2012 Elsevier Inc.
引用
收藏
页码:E115 / E122
页数:8
相关论文
共 50 条
  • [11] Modalities of breast cancer irradiation in 2016: Aims and indications of intensity modulated radiation therapy
    Bourgier, C.
    Fenoglietto, P.
    Lemanski, C.
    Ducteil, A.
    Charissoux, M.
    Draghici, R.
    Azria, D.
    CANCER RADIOTHERAPIE, 2016, 20 (6-7): : 572 - 575
  • [12] Efficient method for whole-breast irradiation therapy using Halcyon linear accelerators
    Tsai, Yi-Chun
    Wang, Chia-Chun
    Wang, Chun-Wei
    Liang, Hsiang-Kung
    Wang, Shu-Fan
    Wu, Chia-Jung
    Lin, Chang-Shiun
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (07):
  • [13] Hybrid planning techniques for hypofractionated whole-breast irradiation using flattening filter-free beams
    Balaji, Karunakaran
    Subramanian, Sitaraman Balaji
    Sathiya, Krishnamoorthi
    Thirunavukarasu, Moorthi
    Radha, Chandrasekaran Anu
    Ramasubramanian, Velayudham
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (04) : 376 - 385
  • [14] Factors modifying the risk for developing acute skin toxicity after whole-breast intensity modulated radiotherapy
    De Langhe, Sofie
    Mulliez, Thomas
    Veldeman, Liv
    Remouchamps, Vincent
    van Greveling, Annick
    Gilsoul, Monique
    De Schepper, Eline
    De Ruyck, Kim
    De Neve, Wilfried
    Thierens, Hubert
    BMC CANCER, 2014, 14
  • [15] Dosimetric comparison of different intensity-modulated radiotherapy techniques for whole-breast irradiation of right-breast cancer
    Song, Y. -q.
    Hong, J.
    Wang, J. -y.
    Peng, J.
    Han, J. -h.
    Luo, H. -l.
    CANCER RADIOTHERAPIE, 2023, 27 (01): : 11 - 16
  • [16] Radiation Oncologists' Views on Breast Radiation Therapy Guidelines: Utilizing an Online Q&A Platform to Assess Current Views on Whole-Breast Irradiation Therapy
    Hsieh, Kristin
    Housri, Nadine
    Haffty, Bruce
    Smith, Benjamin
    Burt, Lindsay M.
    CLINICAL BREAST CANCER, 2021, 21 (05) : 408 - 416
  • [17] Hybrid volumetric modulated arc therapy for whole breast irradiation: a dosimetric comparison of different arc designs
    Ramasubramanian, Velayudham
    Balaji, Karunakaran
    Subramanian, Sitaraman Balaji
    Sathiya, Krishnamoorthi
    Thirunavukarasu, Moorthi
    Radha, Chandrasekaran Anu
    RADIOLOGIA MEDICA, 2019, 124 (06): : 546 - 554
  • [18] Dosimetric evaluation of different planning strategies for hypofractionated whole-breast irradiation technique
    Tang, Chunbo
    Liu, Biaoshui
    Yuan, Jun
    He, Ji
    Xie, Ruilian
    Huang, Minfeng
    Niu, Shanzhou
    Liu, Hongdong
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11)
  • [19] Evaluation of a new commercial automated planning software for tangential breast intensity-modulated radiation therapy
    Mizuno, Norifumi
    Yamauchi, Ryouhei
    Kawamori, Jiro
    Itazawa, Tomoko
    Shimbo, Munefumi
    Nishimura, Keiichiro
    Yamano, Takafumi
    Hatanaka, Shogo
    Hariu, Masatsugu
    Takahashi, Takeo
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2019, 12 (03) : 249 - 259
  • [20] Hypofractionated Whole-Breast Irradiation: Case Closed?
    Recht, Abram
    JOURNAL OF CLINICAL ONCOLOGY, 2020, 38 (31) : 3584 - +