Fast and Environmentally Friendly Quantitative Analysis of Active Agents in Anti-Diabetic Tablets by an Alternative Laser-Induced Breakdown Spectroscopy (LIBS) Method and Comparison to a Validated Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) Method

被引:4
作者
Ulises Contreras, Victor [1 ]
Meneses-Nava, Marco A. [1 ]
Ornelas-Soto, Nancy [1 ]
Barbosa-Garcia, Oracio [1 ]
Lopez-de-Alba, Pedro L. [2 ]
Maldonado, Jose L. [1 ]
Ramos-Ortiz, Gabriel [1 ]
Acevedo-Aguilar, Francisco J. [2 ]
Lopez-Martinez, Leticia [2 ]
机构
[1] Ctr Invest Opt, Leon 37150, Gto, Mexico
[2] Univ Guanajuato, Dept Quim, Guanajuato 36040, Mexico
关键词
Pharmaceuticals; API; Metformin; Glybenclamide; Laser-induced breakdown spectroscopy; LIBS; Spectroscopy; METFORMIN; GLYBURIDE; PLASMA; MICRONUTRIENTS; MANAGEMENT; PRODUCTS; ASSAY;
D O I
10.1366/12-06724
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Laser-induced breakdown spectroscopy (LIBS) is evaluated as a potential analytic technique for rapid screening and quality control of anti-diabetic tablets. This paper proposes a simple LIBS-based method for the quantitative analysis of two active pharmaceutical ingredients (APIs): metformin (Met) and glybenclamide (Gly). In order to quantify both APIs, chlorine (Cl) concentration was estimated by employing the Cl/Br optical emission ratio, where Br was introduced as internal standard. Calibration curves were prepared, achieving linearity higher than 99%. On the other hand, for comparison to the proposed method, an isocratic reversed-phase high-performance liquid chromatography (RP-HPLC) method was also developed for quantitative determination of the same analytes by ultraviolet (UV) detection. The chromatographic separation was achieved on a Phenomenex Hypersil C18, 250 mm x 4.6 mm, 5 mu m column. The mobile phase was K2HPO4/H3PO4-CH3OH and flow rate was 1.0 mL min(-1). The method is linear over a range of 10-60 mu g mL(-1) for Gly and 5-30 mu g mL(-1) for Met and the correlation coefficients were >= 0.99. Recoveries were found to be in the range of 95-101%. Furthermore, four different commercial brands of each active agent were evaluated by both proposed LIBS and chromatographic methods and results were compared with each other. The comparison was satisfactorily validated by analysis of variance (ANOVA).
引用
收藏
页码:1294 / 1301
页数:8
相关论文
共 34 条
[1]   Dried blood spot liquid chromatography assay for therapeutic drug monitoring of metformin [J].
AbuRuz, S ;
Millership, J ;
McElnay, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 832 (02) :202-207
[2]  
Alvey D.C., 2009, APPL OPTICS, V49, P168
[3]  
[Anonymous], 2009, TRENDS ORGAN CRIME, V12, P59
[4]   Rapid characterization of analgesic pills by laser-induced breakdown spectroscopy (LIBS) [J].
Anzano, Jesus ;
Bonilla, Beatriz ;
Montull-Ibor, Beatriz ;
Casas-Gonzalez, Justiniano .
MEDICINAL CHEMISTRY RESEARCH, 2009, 18 (08) :656-664
[5]   Evaluation of laser induced breakdown spectrometry for the determination of macro and micronutrients in pharmaceutical tablets [J].
Arantes de Carvalho, Gabriel Gustinelli ;
Nunes, Lidiane Cristina ;
de Souza, Paulino Florencio ;
Krug, Francisco Jose ;
Alegre, Thaisa Correia ;
Santos, Dario, Jr. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (06) :803-809
[6]   Liquid chromatographic/electrospray ionization mass spectrometric identification of the oxidation end-products of metformin in aqueous solutions [J].
Collin, F ;
Khoury, H ;
Bonnefont-Rousselot, D ;
Thérond, P ;
Legrand, A ;
Jore, D ;
Gardès-Albert, M .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (08) :890-902
[7]   DETECTION OF CHLORINE AND FLUORINE IN AIR BY LASER-INDUCED BREAKDOWN SPECTROMETRY [J].
CREMERS, DA ;
RADZIEMSKI, LJ .
ANALYTICAL CHEMISTRY, 1983, 55 (08) :1252-1256
[8]   Glyburide/metformin tablets: a new therapeutic option for the management of Type 2 diabetes [J].
Dailey, GE .
EXPERT OPINION ON PHARMACOTHERAPY, 2003, 4 (08) :1417-1430
[9]   Retention behavior of metformin and related impurities in ion-pairing liquid chromatography [J].
David, V ;
Medvedovici, A ;
Albu, F .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (01) :81-95
[10]   Time-resolved laser-induced breakdown spectroscopy: Application for qualitative and quantitative detection of fluorine, chlorine, sulfur, and carbon in air [J].
Dudragne, L ;
Adam, P ;
Amouroux, J .
APPLIED SPECTROSCOPY, 1998, 52 (10) :1321-1327