A case-control study of intentional occlusion of accessory renal arteries during endovascular aortic aneurysm repair

被引:42
作者
Malgor, Rafael D. [1 ]
Oderich, Gustavo S. [1 ]
Vrtiska, Terri J. [2 ]
Kalra, Manju [1 ]
Duncan, Audra A. [1 ]
Gloviczki, Peter [1 ]
Cha, Stephen [3 ]
Bower, Thomas C. [1 ]
机构
[1] Mayo Clin, Div Vasc & Endovasc Surg, Rochester, MN 59905 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN 59905 USA
[3] Mayo Clin, Dept Epidemiol & Biostat, Rochester, MN 59905 USA
关键词
PREDICTION;
D O I
10.1016/j.jvs.2013.06.068
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The purpose of this study was to evaluate outcomes of patients treated by intentional coverage of accessory renal artery (ARA) during endovascular abdominal aneurysm repair (EVAR). Methods: The clinical data of 119 patients (110 male and nine female; mean age, 75 years) from a cohort of 811 patients treated by EVAR from 1998 to 2009 was reviewed. Patients who had intentional coverage of at least one ARA (group A) were compared with two control groups, which included patients with no ARA (group B) and those who had ARA preserved during EVAR (group C). All three groups of patients were matched for age, gender, hypertension, and preoperative estimated glomerular filtration rate (eGFR). Paired pre- and postoperative computed tomography angiography was analyzed for the presence and volume of kidney infarction. End points were changes in eGFR, chronic kidney disease (CKD) stage, blood pressure measurements, presence and volume of kidney infarction, freedom from reintervention, and endoleak. Results: There were 42 patients in group A, 42 in group B, and 35 in group C. Demographics, cardiovascular risk factors, and CKD classification were similar in all three groups. Among patients in group A, 44 ARAs were intentionally covered with ARAs originating from the proximal neck in 22 patients, the aneurysm sac in 20, and the iliac arteries in two. There was one (1%) early death in the entire study. Early morbidity was similar in all three groups, including four patients (9%) in group A, four (9%) in group B, and four (11%) in group C (P = .9). Six (5%) patients had >25% decrease in eGFR, including two who had ARA coverage. None of the patients required dialysis. After a mean follow-up of 37 months, there were no differences in late renal function deterioration, changes in eGFR, CKD stage, or blood pressure measurements among the three groups. Three of the 18 patients (17%) with ARA >3 mm arising from the aneurysm sac developed a type II endoleak requiring coil embolization. Kidney infarction was noted in 28 patients (67%) in group A. Freedom from reintervention at 2 years was similar in groups A (64%), B (80%), and C (96%; P = .09). Conclusions: Intentional ARA occlusion during EVAR was not associated with changes in renal function or blood pressure measurements, even when performed in patients with more advanced renal dysfunction. Type II endoleak may result from persistent outflow into large (>3 mm) ARAs that arise from the aneurysm sac.
引用
收藏
页码:1467 / 1475
页数:9
相关论文
共 28 条
  • [11] Comparison of CT Angiography With MR Angiography in the Preoperative Assessment of Living Kidney Donors
    Gluecker, Thomas M.
    Mayr, Michael
    schwarz, Jochen
    Bilecen, Deniz
    Voegele, Thomas
    Steiger, Juerg
    Bachmann, Alexander
    Bongartz, Georg
    [J]. TRANSPLANTATION, 2008, 86 (09) : 1249 - 1256
  • [12] Long-term results after accessory renal artery coverage during endovascular aortic aneurysm repair
    Greenberg, Joshua I.
    Dorsey, Chelsea
    Dalman, Ronald L.
    Lee, Jason T.
    Harris, E. J.
    Hernandez-Boussard, Tina
    Mell, Matthew W.
    [J]. JOURNAL OF VASCULAR SURGERY, 2012, 56 (02) : 291 - 297
  • [13] Intermediate results of a United States multicenter trial of fenestrated endograft repair for juxtarenal abdominal aortic aneurysms
    Greenberg, Roy K.
    Sternbergh, W. Charles, III
    Makaroun, Michel
    Ohki, Takao
    Chuter, Timothy
    Bharadwaj, Priya
    Saunders, Alan
    [J]. JOURNAL OF VASCULAR SURGERY, 2009, 50 (04) : 730 - 737
  • [14] Split renal function measured by triphasic helical CT
    Hackstein, Nils
    Buch, Thomas
    Rau, Wigbert S.
    Weimer, Rolf
    Klett, Rigobert
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2007, 61 (02) : 303 - 309
  • [15] Fenestrated endovascular grafting: The renal side of the story
    Haddad, F
    Greenberg, RK
    Walker, E
    Nally, J
    O'Neill, S
    Kolin, G
    Lyden, SP
    Clair, D
    Sarac, T
    Ouriel, K
    [J]. JOURNAL OF VASCULAR SURGERY, 2005, 41 (02) : 181 - 190
  • [16] Outcome of renal stenting for renal artery coverage during endovascular aortic aneurysm repair
    Hiramoto, Jade S.
    Chang, Catherine K.
    Reilly, Linda M.
    Schneider, Darren B.
    Rapp, Joseph H.
    Chuter, Timothy A. M.
    [J]. JOURNAL OF VASCULAR SURGERY, 2009, 49 (05) : 1100 - 1106
  • [17] Endovascular repair of abdominal aortic aneurysms in patients with congenital renal vascular anomalies
    Kaplan, DB
    Kwon, CC
    Marin, ML
    Hollier, LH
    [J]. JOURNAL OF VASCULAR SURGERY, 1999, 30 (03) : 407 - 415
  • [18] Outcomes of accessory renal artery occlusion during endovascular aneurysm repair
    Karmacharya, J
    Parmer, SS
    Antezana, JN
    Fairman, RM
    Woo, EY
    Velazquez, OC
    Golden, MA
    Carpenter, JP
    [J]. JOURNAL OF VASCULAR SURGERY, 2006, 43 (01) : 8 - 12
  • [20] Endovascular abdominal aortic aneurysm repair using the AneuRx® stent graft:: Impact of excluding accessory renal arteries
    Kim, B
    Donayre, CE
    Hansen, CJ
    Aziz, I
    Walot, I
    Lippmann, M
    Kopchok, GE
    White, RA