Accuracy of Autorefraction in Children A Report by the American Academy of Ophthalmology

被引:29
作者
Wilson, Lorri B. [1 ]
Melia, Michele [2 ]
Kraker, Raymond T. [2 ]
VanderVeen, Deborah K. [3 ]
Hutchinson, Amy K. [4 ]
Pineles, Stacy L. [5 ]
Galvin, Jennifer A. [6 ,7 ]
Lambert, Scott R. [8 ]
机构
[1] Oregon Hlth & Sci Univ, Casey Eye Inst, Portland, OR 97201 USA
[2] Jaeb Ctr Hlth Res, Tampa, FL USA
[3] Harvard Med Sch, Boston Childrens Hosp, Dept Ophthalmol, Boston, MA 02115 USA
[4] Emory Univ, Sch Med, Dept Ophthalmol, Atlanta, GA 30322 USA
[5] Univ Calif Los Angeles, Stein Eye Inst, Los Angeles, CA USA
[6] Yale Sch Med, Eye Phys & Surg PC, Dept Ophthalmol, New Haven, CT USA
[7] Yale Sch Med, Eye Phys & Surg PC, Dept Visual Sci, New Haven, CT USA
[8] Stanford Univ, Sch Med, Dept Ophthalmol, Palo Alto, CA 94304 USA
关键词
HAND-HELD AUTOREFRACTOR; CYCLOPLEGIC AUTOREFRACTION; PRESCHOOL-CHILDREN; REFRACTIVE ERROR; RETINOSCOPY; SCREENER; PLUS;
D O I
10.1016/j.ophtha.2020.03.004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this assessment is to evaluate the accuracy of autorefraction compared with cycloplegic retinoscopy in children. Methods: Literature searches were last conducted in October 2019 in the PubMed and the Cochrane Library databases for studies published in English. The combined searches yielded 118 citations, of which 53 were reviewed in full text. Of these, 31 articles were deemed appropriate for inclusion in this assessment and sub-sequently assigned a level of evidence rating by the panel methodologists. Four articles were rated level I, 11 were rated level II, and 16 were rated level III articles. The 16 level III articles were excluded from this review. Results: Thirteen of the 15 studies comparing cycloplegic autorefraction with cycloplegic retinoscopy found a mean difference in spherical equivalent or sphere of less than 0.5 diopters (D); most were less than 0.25 D. Even lower mean differences were found when evaluating the cylindrical component of cycloplegic autorefraction versus cycloplegic retinoscopy. Despite low mean variability, there was significant individual measurement variability; the 95% limits of agreement were wide and included clinically relevant differences. Comparisons of noncycloplegic with cycloplegic autorefractions found that noncyloplegic refraction tends to over minus by 1 to 2 D. Conclusions: Cycloplegic autorefraction is appropriate to use in pediatric population-based studies. Cycloplegic retinoscopy can be valuable in individual clinical cases to confirm the accuracy of cycloplegic autorefraction, particularly when corrected visual acuity is worse than expected or the autorefraction results are not consistent with expected findings. (C) 2020 by the American Academy of Ophthalmology
引用
收藏
页码:1259 / 1267
页数:9
相关论文
共 19 条
[1]   A comparison of autorefraction and subjective refraction with and without cycloplegia in primary school children [J].
Choong, Yee-Fong ;
Chen, Ai-Hong ;
Goh, Pik-Pin .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (01) :68-74
[2]  
Da Gama Rita Dinis, 2013, Binocul Vis Strabolog Q Simms Romano, V28, P229
[3]   Plusoptix Vision Screener: the accuracy and repeatability of refractive measurements using a new autorefractor [J].
Dahlmann-Noor, A. H. ;
Comyn, O. ;
Kostakis, V. ;
Misra, A. ;
Gupta, N. ;
Heath, J. ;
Brown, J. ;
Iron, A. ;
McGill, S. ;
Vrotsou, K. ;
Vivian, A. J. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (03) :346-349
[4]  
El-Defrawy S, 1998, J PEDIAT OPHTH STRAB, V35, P107
[5]   Prevalence of Astigmatism in 6-to 72-Month-Old African American and Hispanic Children: The Multi-Ethnic Pediatric Eye Disease Study [J].
Fozailoff, Arezoo ;
Tarczy-Hornoch, Kristina ;
Cotter, Susan ;
Wen, Ge ;
Lin, Jesse ;
Borchert, Mark ;
Azen, Stanley ;
Varma, Rohit .
OPHTHALMOLOGY, 2011, 118 (02) :284-293
[6]   Prevalence of Refractive Error among Preschool Children in an Urban Population: The Baltimore Pediatric Eye Disease Study [J].
Giordano, Lydia ;
Friedman, David S. ;
Repka, Michael X. ;
Katz, Joanne ;
Ibironke, Josephine ;
Hawes, Patricia ;
Tielsch, James M. .
OPHTHALMOLOGY, 2009, 116 (04) :739-746
[7]   Comparison of the Retinomax autorefractor with hand-held retinoscopy in 1-year-old infants [J].
Gole, GA ;
Schluter, PJ ;
Hall, J ;
Colville, D .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2003, 31 (04) :341-347
[8]   A comparison of cycloplegic autorefraction and retinoscopy in Indian children [J].
Guha, Sujata ;
Shah, Sanil ;
Shah, Khyati ;
Hurakadli, Preeti ;
Majee, Debalina ;
Gandhi, Shyamali .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2017, 100 (01) :73-78
[9]   Progressive-Addition Lenses versus Single-Vision Lenses for Slowing Progression of Myopia in Children with High Accommodative Lag and Near Esophoria [J].
Gwiazda, Jane ;
Chandler, Danielle L. ;
Cotter, Susan A. ;
Everett, Donald F. ;
Hyman, Leslie ;
Kaminski, Brett M. ;
Kulp, Marjean T. ;
Lyon, Don W. ;
Manny, Ruth E. ;
Marsh-Tootle, Wendy L. ;
Matta, Noelle S. ;
Melia, B. Michele ;
Norton, Thomas T. ;
Scheiman, Mitchell M. ;
Silbert, David I. ;
Weissberg, Erik M. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) :2749-2757
[10]   Measurement of refractive error in Native American preschoolers: Validity and reproducibility of autorefraction [J].
Harvey, EM ;
Miller, JM ;
Dobson, V ;
Tyszko, R ;
Davis, AL .
OPTOMETRY AND VISION SCIENCE, 2000, 77 (03) :140-149