An electronic pressure-meter nociception paw test for mice

被引:267
作者
Cunha, TM [1 ]
Verri, WA [1 ]
Vivancos, GG [1 ]
Moreira, IF [1 ]
Reis, S [1 ]
Parada, CA [1 ]
Cunha, FQ [1 ]
Ferreira, SH [1 ]
机构
[1] Univ Sao Paulo, Fac Med Ribeirao Preto, Dept Farmacol, Ribeirao Preto, Brazil
关键词
hyperalgesia; nociception; indomethacin; dipyrone; von Frey filaments;
D O I
10.1590/S0100-879X2004000300018
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of the present investigation was to describe and validate an electronic mechanical test for quantification of the intensity of inflammatory nociception in mice. The electronic pressure-meter test consists of inducing the animal hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared to the classical von Frey filaments test in which pressure intensity is automatically recorded after the nociceptive hindpaw flexion reflex. The electronic pressure-meter and the von Frey filaments were used to detect time versus treatment interactions of carrageenin-induced hypernociception. In two separate experiments, the electronic pressure-meter was more sensitive than the von Frey filaments for the detection of the increase in nociception (hypernociception) induced by small doses of carrageenin (30 mug). The electronic pressure-meter detected the antinociceptive effect of nonsteroidal drugs in a dose-dependent manner. Indomethacin administered intraperitoneally (1.8-15 mg/kg) of intraplantarly (30-300 mug/ paw) prevented the hypersensitive effect of carrageenin (100 mug/ paw). The electronic pressure-meter also detected the hypernociceptive effect of prostaglandin E-2 (PGE(2); 10-100 ng) in a dose-dependent manner. The hypernociceptive, effect of PGE(2) (100 ng) was blocked by dipyrone (160 and 320 mug/paw) but not by intraplantar administration of indomethacin (300 mug/paw). The present results validate the use of the electronic pressure-meter as more sensitive than the von Frey filaments in mice. Furthermore, it is an objective and quantitative nociceptive test for the evaluation of the peripheral antinociceptive effect of anti-inflammatory analgesic drugs, which inhibit prostaglandin synthesis (indomethacin) or directly block the ongoing hypernociception (dipyrone).
引用
收藏
页码:401 / 407
页数:7
相关论文
共 20 条
[1]   Involvement of ATP-sensitive K+ channels in the peripheral antinociceptive effect induced by dipyrone [J].
Alves, DP ;
Duarte, IDG .
EUROPEAN JOURNAL OF PHARMACOLOGY, 2002, 444 (1-2) :47-52
[2]   CONTRIBUTION OF PROTEIN-KINASE-C TO CENTRAL SENSITIZATION AND PERSISTENT PAIN FOLLOWING TISSUE-INJURY [J].
CODERRE, TJ .
NEUROSCIENCE LETTERS, 1992, 140 (02) :181-184
[3]   Pharmacological modulation of secondary mediator systems - cyclic AMP and cyclic GMP - on inflammatory hyperalgesia [J].
Cunha, FQ ;
Teixeira, MM ;
Ferreira, SH .
BRITISH JOURNAL OF PHARMACOLOGY, 1999, 127 (03) :671-678
[4]   PROSTAGLANDIN HYPERALGESIA .1. CAMP-CA2+ DEPENDENT PROCESS [J].
FERREIRA, SH ;
NAKAMURA, M .
PROSTAGLANDINS, 1979, 18 (02) :179-190
[5]  
FERREIRA SH, 1973, BRIT J PHARMACOL, V49, P86, DOI 10.1111/j.1476-5381.1973.tb08270.x
[6]  
GREENSPAN JD, 1990, PAIN S, V5, pS313
[7]   PRESSURE-PAIN THRESHOLD IN HUMAN TEMPORAL REGION - EVALUATION OF A NEW PRESSURE ALGOMETER [J].
JENSEN, K ;
ANDERSEN, HO ;
OLESEN, J ;
LINDBLOM, U .
PAIN, 1986, 25 (03) :313-323
[8]  
Le Bars D, 2001, PHARMACOL REV, V53, P597
[9]   Activation of the arginine-nitric oxide pathway in primary sensory neurons contributes to dipyrone-induced spinal and peripheral analgesia [J].
Lorenzetti, BB ;
Ferreira, SH .
INFLAMMATION RESEARCH, 1996, 45 (06) :308-311
[10]   Inhibition of forskolin-induced sensitisation of frog skin nociceptors by the cyclic AMP-dependent protein kinase A antagonist H-89 [J].
Lynn, B ;
O'Shea, NR .
BRAIN RESEARCH, 1998, 780 (02) :360-362