Differential diagnosis between benign and malignant pleural effusion with dual-energy spectral CT

被引:32
作者
Zhang, Xirong [1 ,2 ,3 ]
Duan, Haifeng [2 ,4 ]
Yu, Yong [2 ]
Ma, Chunling [2 ]
Ren, Zhanli [2 ]
Lei, Yuxin [2 ]
He, Taiping [2 ]
Zhang, Ming [1 ]
机构
[1] Xi An Jiao Tong Univ, Coll Med, Affiliated Hosp 1, Dept Radiol, Xian, Shaanxi, Peoples R China
[2] Shaanxi Univ Chinese Med, Affiliated Hosp, Dept Radiol, Xianyang City, Shaanxi, Peoples R China
[3] Shaanxi Univ Chinese Med, Dept Med Tech, Xianyang City, Shaanxi, Peoples R China
[4] Dept Med Imaging, 2 Weiyangxi Rd, Xianyang City, Shaanxi, Peoples R China
关键词
COMPUTED-TOMOGRAPHY; ATTENUATION VALUES; THORACOSCOPY;
D O I
10.1371/journal.pone.0193714
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To investigate the value of spectral CT in the differential diagnosis of benign from malignant pleural effusion. Method and materials 14 patients with benign pleural effusion and 15 patients with malignant pleural effusion underwent non-contrast spectral CT imaging. These patients were later verified by the combination of disease history, clinical signs and other information with the consensus of surgeons and radiologists. Various Spectral CT image parameters measured for the effusion were as follows: CT numbers of the polychromatic 140kVp images, monochromatic images at 40keV and 100keV, the material density contents from the water, fat and blood-based material decomposition images, the effective atomic number and the spectral curve slope. These values were statistically compared with t test and logistic regression analysis between benign and malignant pleural effusion. Results The CT value of benign and malignant pleural effusion in the polychromatic 140kVp images showed no differences (12.61 +/- 3.39HU vs. 14.71 +/- 5.03HU) (P>0.05), however, they were statistically different on the monochromatic images at 40keV (43.15 +/- 3.79 vs. 39.42 +/- 2.60, p=0.005) and 100keV (9.11 +/- 1.38 vs. 6.52 +/- 2.04, p< 0.001). There was difference in the effective atomic number value between the benign (7.87 +/- 0.08) and malignant pleural effusion (7.90 +/- 0.02) (P=0.02). Using 6.32HU as the threshold for CT value measurement at 100keV, one could obtain sensitivity of 100% and specificity of 66.7% with area-under-curve of 0.843 for differentiating benign from malignant effusion. In addition, age and disease history were potential confounding factors for differentiating malignant pleural effusion from benign, since the older age (61.13 +/- 12.51 year-old vs48.57 +/- 12.33 year-old) as well as longer disease history (70.00 +/- 49.28 day vs. 28.36 +/- 21.64 day) were more easily to be found in the malignant pleural effusion group than those in the benign pleural effusion group. By combining above five factors, one could obtain sensitivity of 100% and specificity of 71.4% with area-under-curve of 0.933 for differentiating benign from malignant effusion. Conclusion The CT value measurement at both high and low energy levels and the effective atomic number obtained in a single spectral CT scan can assist the differential diagnosis of benign from malignant pleural effusion. Combining them with patient age and disease history can further improve diagnostic performance. Clinical relevance/Application Clinical findings and Spectral CT imaging can provide significant evidences about the nature of pleural effusion.
引用
收藏
页数:11
相关论文
共 23 条
[1]   Pleural Effusion: Characterization with CT Attenuation Values and CT Appearance [J].
Abramowitz, Yigal ;
Simanovsky, Natalia ;
Goldstein, Michael S. ;
Hiller, Nurith .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) :618-623
[2]   Differentiating between malignant and idiopathic pleural effusions:: the value of diagnostic procedures [J].
Aleman, C. ;
Sanchez, L. ;
Alegre, J. ;
Ruiz, E. ;
Vazquez, A. ;
Soriano, T. ;
Sarrapio, J. ;
Teixidor, J. ;
Andreu, J. ;
Felip, E. ;
Armadans, L. ;
De Sevilla, T. Fernandez .
QJM-AN INTERNATIONAL JOURNAL OF MEDICINE, 2007, 100 (06) :351-359
[3]   The diagnostic value of survivin in malignant pleural effusion: A meta-analysis [J].
Chen, Shi ;
Wang, Yunfang ;
An, Li ;
Fei, Zhong-ting ;
Li, Tian .
CLINICA CHIMICA ACTA, 2015, 441 :142-147
[4]   Efficacy of CT in diagnosis of transudates and exudates in patients with pleural effusion [J].
Cullu, Nesat ;
Kalemci, Serdar ;
Karakas, Omer ;
Eser, Irfan ;
Yalcin, Funda ;
Boyaci, Fatima Nurefsan ;
Karakas, Ekrem .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2014, 20 (02) :116-120
[5]   Preliminary Application of High-Definition CT Gemstone Spectral Imaging in Hand and Foot Tendons [J].
Deng, Kai ;
Zhang, Cheng-Qi ;
Li, Wei ;
Wang, Jun-Jun ;
Wang, Xin-Yi ;
Pang, Tao ;
Wang, Guang-Li ;
Liu, Cheng .
KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (06) :743-751
[6]   Differential diagnosis of osteoblastic metastases from bone islands in patients with lung cancer by single-source dual-energy CT: Advantages of spectral CT imaging [J].
Dong Yue ;
Zheng Shaowei ;
Machida, Haruhiko ;
Wang Bing ;
Liu Ailian ;
Liu Yijun ;
Zhang Xin .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (05) :901-907
[7]   Preliminary study on the differentiation between parapelvic cyst and hydronephrosis with non-calculous using only pre-contrast dual-energy spectral CT scans [J].
Han, Dong ;
Ma, Guangming ;
Wei, Lequn ;
Ren, Chenglong ;
Zhou, Jieli ;
Shen, Chen ;
He, Taiping .
BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1073)
[8]   Recent advances in the diagnosis and management of malignant pleural effusions [J].
Heffner, John E. ;
Klein, Jeffrey S. .
MAYO CLINIC PROCEEDINGS, 2008, 83 (02) :235-250
[9]   Diagnostic accuracy of tumor necrosis factor-alpha, interferon-gamma, interlukine-10 and adenosine deaminase 2 in differential diagnosis between tuberculous pleural effusion and malignant pleural effusion [J].
Li, Mingying ;
Wang, Helin ;
Wang, Xia ;
Huang, Jian ;
Wang, Junxiang ;
Xi, Xiue .
JOURNAL OF CARDIOTHORACIC SURGERY, 2014, 9
[10]  
Liao P, 2017, STAT BIOSCIENCES, V1-14, DOI [10.1007/s12561-016-9144-1, DOI 10.1007/S12561-016-9144-1]