Occult fractures of the waist of the scaphoid: Early diagnosis by high-spatial-resolution sonography

被引:65
作者
Hauger, O
Bonnefoy, O
Moinard, M
Bersani, D
Diard, F
机构
[1] CHRU Bordeaux, Grp Hosp Pellegrin, Serv Radiol, F-33076 Bordeaux, France
[2] Ctr Hosp Gen Pau, Serv Radiol, F-64000 Pau, France
关键词
D O I
10.2214/ajr.178.5.1781239
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This study evaluated the diagnostic accuracy of high-spatial-resolution sonography in the diagnosis of occult fractures of the waist of the scaphoid. SUBJECTS AND METHODS. Sonography of the scaphoid bone with a 12-MHz transducer was performed in 54 patients with clinicaly suspected scaphoid fracture and normal findings on initial radiographs, including specific scaphoid images. Three levels of clinical suspicion were considered: high (20%), moderate (30%), and low (50%). Attention was paid to the continuity of the scaphoid cortex and to the surrounding soft tissues (i.e., hemarthrosis or hematoma). Data from early sonograms were then compared with the results of radiography repeated 10-14 days after the initial trauma. In cases of persistent suspicion despite normal findings on follow-up radiographs, the presence of fracture was evaluated on CT (four patients), MR imaging (one patient), or bone scanning (one patient). RESULTS. Follow-up examinations proved fracture of the scaphoid waist in five patients. In all patients, diagnosis of fracture was suspected on initial sonograms showing cortical disruption associated with soft-tissue abnormalities. There was one false-positive finding and no false-negative results. Using cortical disruption as a diagnostic criterion, we found the sensitivity, specificity, and accuracy of high-resolution sonography for the depiction of scaphoid fracture to be 100%, 98%, and 98%, respectively. Using soft-tissue abnormalities alone as a criterion, we found the sensitivity, specificity, and accuracy of high-resolution sonography to be 100%, 65%, and 68%, respectively. The overall prevalence of occult fracture was 9%, ranging from 3.7% for low suspicion to 27% for high suspicion of fracture. CONCLUSION. High-resolution sonography is a reliable and accurate method of evaluating occult fractures of the scaphoid waist. Cortical disruption is the diagnostic key. Soft-tissue abnormalities alone lack specificity.
引用
收藏
页码:1239 / 1245
页数:7
相关论文
共 34 条
[1]   Radiographically occult scaphoid fractures: Value of MR imaging in detection [J].
Breitenseher, MJ ;
Metz, VM ;
Gilula, LA ;
Gaebler, C ;
Kukla, C ;
Fleischmann, D ;
Imhof, H ;
Trattnig, S .
RADIOLOGY, 1997, 203 (01) :245-250
[2]  
BRISMAR J, 1988, ACTA RADIOL, V29, P101
[3]   FRACTURE OF THE CARPAL SCAPHOID - FREQUENCY AND DISTRIBUTION IN A WELL-DEFINED POPULATION [J].
BRONDUM, V ;
LARSEN, CF ;
SKOV, O .
EUROPEAN JOURNAL OF RADIOLOGY, 1992, 15 (02) :118-122
[4]   Suspected scaphoid fractures in skeletally immature patients: Application of MRI [J].
Cook, PA ;
Yu, JS ;
Wiand, W ;
Cook, AJ ;
Coleman, CR ;
Cook, AJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (04) :511-515
[5]   CLINICAL FRACTURE OF THE CARPAL SCAPHOID - AN ILLUSIONARY DIAGNOSIS [J].
DUNCAN, DS ;
THURSTON, AJ .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1985, 10B (03) :375-376
[6]   WHAT VALUE THE SCAPHOID COMPRESSION TEST [J].
ESBERGER, DA .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1994, 19B (06) :748-749
[7]   Herbert screw fixation of scaphoid fractures [J].
Filan, SL ;
Herbert, TJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (04) :519-529
[8]  
FRIEDMAN L, 1990, J CAN ASSOC RADIOL, V41, P141
[9]   Magnetic resonance imaging of occult scaphoid fractures [J].
Gaebler, C ;
Kukla, C ;
Breitenseher, M ;
Trattnig, S ;
Mittlboeck, M ;
Vecsei, V .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 41 (01) :73-76
[10]   Acute percutaneous scaphoid fixation - A pilot study [J].
Haddad, FS ;
Goddard, NJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01) :95-99