Three-dimensional ultrasonography using the minimum transparent mode in obstructive biliary diseases - Early experience

被引:4
作者
Lee, HJ
Choi, BI
Han, JK
Kim, AY
Kim, KW
Park, SH
Jeong, JY
Kang, JW
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Clin Res Inst, Chongno Gu, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
关键词
biliary disease; three-dimensional; ultrasonography;
D O I
10.7863/jum.2002.21.4.443
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. To assess the feasibility of three-dimensional ultrasonography using the minimum transparent mode in patients with obstructive biliary disease. Methods. Fourteen patients with obstructive jaundice underwent three-dimensional ultrasonography after conventional two-dimensional ultrasonography before interventional procedures. Three-dimensional images reconstructed by the minimum transparent mode were evaluated and compared with direct cholangiography. The minimum transparent mode images were compared with the two-dimensional ultrasonographic images to determine whether additional information was obtained. Results. The level of obstruction was correctly depicted in all patients, and a dilated common bile duct, common hepatic duct, gallbladder, and main intrahepatic ducts were well visualized on minimum transparent mode images. The findings on minimum transparent mode images were well correlated with those on cholangiography; however, the perspective of the whole biliary tree on minimum transparent mode images was inferior to that on cholangiography in all cases. The overall image quality of minimum transparent mode images was poor in 6 patients, fair in 3, good in 4, and excellent in 1. The biliary anatomy was more objectively visualized on the minimum transparent mode images than conventional two-dimensional ultrasonographic images. Conclusions. Three-dimensional ultrasonography using the minimum transparent mode appears to be clinically feasible. The biliary anatomy was more objectively visualized on the minimum transparent mode images than conventional two-dimensional ultrasonographic images. Further technical development is needed to improve imaging resolution.
引用
收藏
页码:443 / 453
页数:11
相关论文
共 26 条
  • [1] AUTOMATED PROSTATE VOLUME DETERMINATION WITH ULTRASONOGRAPHIC IMAGING
    AARNINK, RG
    HUYNEN, AL
    GIESEN, RJB
    DELAROSETTE, JJMCH
    DEBRUYNE, FMJ
    WIJKSTRA, H
    [J]. JOURNAL OF UROLOGY, 1995, 153 (05) : 1549 - 1554
  • [2] Diagnosis of congenital malformations using two-dimensional and three-dimensional ultrasonography
    Chan, L
    Uerpairojkit, B
    Reece, EA
    [J]. OBSTETRICS AND GYNECOLOGY CLINICS OF NORTH AMERICA, 1997, 24 (01) : 49 - &
  • [3] Chin J L, 1996, Tech Urol, V2, P187
  • [4] Clinical utility of three-dimensional US
    Downey, DB
    Fenster, A
    Williams, JC
    [J]. RADIOGRAPHICS, 2000, 20 (02) : 559 - 571
  • [5] 3-DIMENSIONAL POWER DOPPLER DETECTION OF PROSTATIC-CANCER
    DOWNEY, DB
    FENSTER, A
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) : 741 - 741
  • [6] VASCULAR IMAGING WITH A 3-DIMENSIONAL POWER DOPPLER SYSTEM
    DOWNEY, DB
    FENSTER, A
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) : 665 - 668
  • [7] Three-dimensional ultrasound imaging of the eye
    Downey, DB
    Nicolle, DA
    Levin, MF
    Fenster, A
    [J]. EYE, 1996, 10 : 75 - 81
  • [8] Accuracy of prostate volume measurements in vitro using three-dimensional ultrasound
    Elliot, TL
    Downey, DB
    Tong, SD
    McLean, CA
    Fenster, A
    [J]. ACADEMIC RADIOLOGY, 1996, 3 (05) : 401 - 406
  • [9] 3-DIMENSIONAL (3D) ULTRASOUND IMAGING OF THE GALLBLADDER AND DILATED BILIARY TREE - RECONSTRUCTION FROM REAL-TIME B-SCANS
    FINE, D
    PERRING, S
    HERBETKO, J
    HACKING, CN
    FLEMING, JS
    DEWBURY, KC
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (767) : 1056 - 1057
  • [10] Three-dimensional US of the prostate: Early experience
    Hamper, UM
    Trapanotto, V
    DeJong, MR
    Sheth, S
    Caskey, CI
    [J]. RADIOLOGY, 1999, 212 (03) : 719 - 723