Evaluation of the inter-rater and intra-rater reliability of a protocol for the measurement of foot-transmitted vibration

被引:1
|
作者
Vance, Brandon [1 ]
Goggins, Katie A. [2 ]
Godwin, Alison [1 ]
Oddson, Bruce E. [1 ]
Eger, Tammy R. [1 ]
机构
[1] Laurentian Univ, Sch Human Kinet, 935 Ramsey Lake Rd, Sudbury, ON P3E 2C6, Canada
[2] Laurentian Univ, Bharti Sch Engn, Sudbury, ON, Canada
关键词
Vibration; standardisation; standing; reliability; validation; measurement protocol; WHOLE-BODY VIBRATION; BIODYNAMIC RESPONSES; METHOD VALIDATION; TRANSMISSION; EXPOSURE; PERFORMANCE; DISCOMFORT; PRESSURE; GLOVES;
D O I
10.1080/1463922X.2020.1811922
中图分类号
TB18 [人体工程学];
学科分类号
1201 ;
摘要
Foot-transmitted vibration (FTV) is an occupational hazard in construction, forestry and mining which places workers at risk of vibration-induced white-foot. A universally accepted measurement protocol (MP) for evaluating FTV exposure does not exist. As such, the purpose of this study was to determine the inter-rater and intra-rater reliability of the selected FTV-MP using different research assistants (RA) to take the FTV measurements. Preliminary tests evaluating changes in measured FTV using different accelerometer mounting locations and orientations, participant standing postures, time of day of measurements and trial duration. The results of this testing, combined with results from literature using a laser Doppler vibrometer at 24 anatomical locations on the foot, developed an FTV-MP requiring the use of two accelerometers secured to the platform and two to the right foot (first metatarsal head and medial malleolus), to capture anatomical locations with the highest and lowest transmissibility. RA repeatedly attached the accelerometers to the platform and participants as previously described. Inter- and intra-rater reliability was assessed for all vibration measures using intraclass correlation (ICC) tests and three raters. ICCs revealed reliability coefficients in the range of 'good' reliability for 3 of the 4 measurement locations and moderate reliability at the ankle (r.m.s. acceleration).
引用
收藏
页码:219 / 236
页数:18
相关论文
共 50 条
  • [1] Inter-rater and Intra-rater Reliability of the Videofluoroscopic Dysphagia Scale with the Standardized Protocol
    Min, Ingi
    Woo, Hyeonseong
    Kim, Jae Yoon
    Kim, Tae-Lim
    Lee, Yookyung
    Chang, Won Kee
    Jung, Se Hee
    Lee, Woo Hyung
    Oh, Byung-Mo
    Han, Tai Ryoon
    Seo, Han Gil
    DYSPHAGIA, 2024, 39 (01) : 43 - 51
  • [2] Inter-rater and Intra-rater Reliability of the Videofluoroscopic Dysphagia Scale with the Standardized Protocol
    Ingi Min
    Hyeonseong Woo
    Jae Yoon Kim
    Tae-Lim Kim
    Yookyung Lee
    Won Kee Chang
    Se Hee Jung
    Woo Hyung Lee
    Byung-Mo Oh
    Tai Ryoon Han
    Han Gil Seo
    Dysphagia, 2024, 39 : 43 - 51
  • [3] Validation of Inter-Rater and Intra-Rater Reliability of Remote Dielectric Sensing Measurement
    Hori, Masakazu
    Imamura, Teruhiko
    Fukuo, Atsuko
    Fukui, Takuya
    Koi, Takatoshi
    Ueno, Yohei
    Onoda, Hiroshi
    Tanaka, Shuhei
    Ushijima, Ryuichi
    Sobajima, Mitsuo
    Fukuda, Nobuyuki
    Ueno, Hiroshi
    Kinugawa, Koichiro
    INTERNATIONAL HEART JOURNAL, 2022, 63 (01) : 73 - 76
  • [4] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas
    EURASIAN JOURNAL OF EDUCATIONAL RESEARCH, 2014, (57): : 113 - 135
  • [5] Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
    Mihalinec, Katja
    Martinez-Cepa, Carmen B.
    Zuil-Escobar, Juan C.
    Kejzar, Natasa
    Vauhnik, Renata
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [6] Inter-rater and intra-rater reliability of a clinical protocol for measuring turnout in collegiate dancers
    Greene, Amanda
    Lasner, Andrea
    Deu, Rajwinder
    Oliphant, Seth
    Johnson, Kenneth
    PHYSIOTHERAPY THEORY AND PRACTICE, 2019, 35 (01) : 94 - 99
  • [7] Intra-rater and inter-rater reliability of the standardized ultrasound protocol for assessing subacromial structures
    Hougs Kjaer, Birgitte
    Ellegaard, Karen
    Wieland, Ina
    Warming, Susan
    Juul-Kristensen, Birgit
    PHYSIOTHERAPY THEORY AND PRACTICE, 2017, 33 (05) : 398 - 409
  • [8] Inter-rater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion
    Reham M. Abd Elrahim
    Eman A. Embaby
    Mohamed F. Ali
    Ragia M. Kamel
    Bulletin of Faculty of Physical Therapy, 2016, 21 (2) : 80 - 87
  • [9] Optoelectronic plethysmography: Intra-rater and inter-rater reliability in healthy subjects
    Vieira, Danielle S. R.
    Hoffman, Mariana
    Pereira, Danielle A. G.
    Britto, Raquel R.
    Parreira, Veronica F.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2013, 189 (03) : 473 - 476
  • [10] INTER-RATER AND INTRA-RATER RELIABILITY OF UROFLOWMETRY INTERPRETATION IN ADULT WOMEN
    Rickey, Leslie M.
    Mueller, Elizabeth R.
    Newman, Diane K.
    Markland, Alayne D.
    Falke, Chloe
    Rudser, Kyle
    Lukacz, Emily S.
    JOURNAL OF UROLOGY, 2023, 209 : E519 - E519