Reliability Comparison of Boost PFC Converter in DCM and CCM Operating Modes

被引:12
作者
Abdi, B. [1 ]
Ranjbar, A. H. [1 ]
Milimonfared, J. [1 ]
Gharehpetian, G. B. [1 ]
机构
[1] Amir Kabir Univ Technol, Dept Elect Engn, Tehran, Iran
来源
2008 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, VOLS 1-3 | 2008年
关键词
Boost; Converter; PFC; Reliability;
D O I
10.1109/SPEEDHAM.2008.4581288
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Reliability plays an important role in power electronic systems by which the number of system failures, repair costs, guarantee and etc are estimated. In this paper first, a boost Power Factor Correction (PFC) converter is simulated in Discontinues Conduction Mode (DCM) and Continuous Conduction Mode (CCM) under different output power ratings. For these simulations, all of the inherent parameters of MOSFET and diodes are applied according to the actual types. Then, reliability calculation is done based on MIL-HDBK-217 standard. Results have shown that the boost PFC converter would have better performance from reliability point of view in CCM operating mode.