Maximum efficiency radiofrequency shimming: Theory and initial application for hip imaging at 7 tesla

被引:26
作者
Deniz, Cem Murat [1 ,2 ]
Brown, Ryan [1 ]
Lattanzi, Riccardo [1 ,2 ]
Alon, Leeor [1 ,2 ]
Sodickson, Daniel K. [1 ,2 ]
Zhu, Yudong [1 ,2 ]
机构
[1] NYU, Sch Med, Bernard & Irene Schwartz Ctr Biomed Imaging, Dept Radiol, New York, NY 10016 USA
[2] NYU, Sch Med, Sackler Inst Grad Biomed Sci, New York, NY 10016 USA
关键词
radiofrequency shimming; B1; shimming; adiabatic excitation; radiofrequency power deposition; specific absorption rate; ultra-high-field MRI; hip; hip articular cartilage; EXCITATION PULSE DESIGN; HIGH-FIELD MRI; FEMOROACETABULAR IMPINGEMENT; PARALLEL EXCITATION; POWER DEPOSITION; RF; SAR; INHOMOGENEITY; TRANSMISSION; CARTILAGE;
D O I
10.1002/mrm.24377
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radiofrequency shimming with multiple channel excitation has been proposed to increase the transverse magnetic field uniformity and reduce specific absorption rate at high magnetic field strengths (7 T) where high-frequency effects can make traditional single channel volume coils unsuitable for transmission. In the case of deep anatomic regions and power-demanding pulse sequences, optimization of transmit efficiency may be a more critical requirement than homogeneity per se. This work introduces a novel method to maximize transmit efficiency using multiple channel excitation and radiofrequency shimming. Shimming weights are calculated in order to obtain the lowest possible net radiofrequency power deposition into the subject for a given transverse magnetic field strength. The method was demonstrated in imaging studies of articular cartilage of the hip joint at 7 T. We show that the new radiofrequency shimming method can enable reduction in power deposition while maintaining an average flip angle or adiabatic condition in the hip cartilage. Building upon the improved shimming, we further show that the signal-to-noise ratio in hip cartilage at 7 T can be substantially greater than that at 3 T, illustrating the potential benefits of high field hip imaging. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1379 / 1388
页数:10
相关论文
共 33 条
[1]  
Alon L., 2010, Proceedings of the 18th Scientific Meeting, P780
[2]  
Balchandani P., 2011, Proceedings of the 19th Scientific Meeting, P2907
[3]  
Beck M, 2004, CLIN ORTHOP RELAT R, P67
[4]   Feasibility of T2* Mapping for the Evaluation of Hip Joint Cartilage at 1.5T Using a Three-Dimensional (3D), Gradient-Echo (GRE) Sequence: A Prospective Study [J].
Bittersohl, Bernd ;
Hosalkar, Harish S. ;
Hughes, Tim ;
Kim, Young-Jo ;
Werlen, Stefan ;
Siebenrock, Klaus A. ;
Mamisch, Tallal C. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) :896-901
[5]  
Brown R, 2010, P 18 ANN M ISMRM STO, P3807
[6]   Specific absorption rate benefits of including measured electric field interactions in parallel excitation pulse design [J].
Deniz, Cem Murat ;
Alon, Leeor ;
Brown, Ryan ;
Sodickson, Daniel K. ;
Zhu, Yudong .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) :164-174
[7]  
Fautz HP., 2008, Proceedings of the 16th Scientific Meeting, P1247
[8]   Femoroacetabular impingement -: A cause for osteoarthritis of the hip [J].
Ganz, R ;
Parvizi, J ;
Beck, M ;
Leunig, M ;
Nötzli, H ;
Siebenrock, KA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :112-120
[9]   The return of the frequency sweep: Designing adiabatic pulses for contemporary NMR [J].
Garwood, M ;
DelaBarre, L .
JOURNAL OF MAGNETIC RESONANCE, 2001, 153 (02) :155-177
[10]   Spatial domain method for the design of RF pulses in multicoil parallel excitation [J].
Grissom, William ;
Yip, Chun-yu ;
Zhang, Zhenghui ;
Stenger, V. Andrew ;
Fessler, Jeffrey A. ;
Noll, Douglas C. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (03) :620-629