Computer-aided detection of masses in full-field digital mammography using screen-film mammograms for training

被引:17
作者
Kallenberg, Michiel [1 ]
Karssemeijer, Nico [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Radiol, NL-6525 GA Nijmegen, Netherlands
关键词
D O I
10.1088/0031-9155/53/23/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It would be of great value when available databases of screen-film mammography (SFM) images can be used to train full-field digital mammography (FFDM) computer-aided detection (CAD) systems, as compilation of new databases is costly. In this paper, we investigate this possibility. Firstly, we develop a method that converts an FFDM image into an SFM-like representation. In this conversion method, we establish a relation between exposure and optical density by simulation of an automatic exposure control unit. Secondly, we investigate the effects of using the SFM images as training samples compared to training with FFDM images. Our FFDM database consisted of 266 cases, of which 102 were biopsy-proven malignant masses and 164 normals. The images were acquired with systems of two different manufacturers. We found that, when we trained our FFDM CAD system with a small number of images, training with FFDM images, using a five-fold crossvalidation procedure, outperformed training with SFM images. However, when the full SFM database, consisting of 348 abnormal cases (including 204 priors) and 810 normal cases, was used for training, SFM training outperformed FFDMA training. These results show that an existing CAD system for detection of masses in SFM can be used for FFDM images without retraining.
引用
收藏
页码:6879 / 6891
页数:13
相关论文
共 26 条
[1]  
[Anonymous], IARC CANC BASE
[2]  
BARNES G, 1993, SYLLABUS CATEGORICAL, P59
[3]   Single and multiscale detection of masses in digital mammograms [J].
Brake, GMT ;
Karssemeijer, N .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (07) :628-639
[4]   Sample size and validation issues on the development of CAD systems [J].
Chan, HP ;
Sahiner, B ;
Hadjiiski, L .
CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 :872-877
[5]   Classifier design for computer-aided diagnosis: Effects of finite sample size on the mean performance of classical and neural network classifiers [J].
Chan, HP ;
Sahiner, B ;
Wagner, RF ;
Petrick, N .
MEDICAL PHYSICS, 1999, 26 (12) :2654-2668
[6]   EFFECTS OF SAMPLE-SIZE IN CLASSIFIER DESIGN [J].
FUKUNAGA, K ;
HAYES, RR .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1989, 11 (08) :873-885
[7]  
Highnam R., 1999, Mammographic Image Analysis
[8]  
HURTER F, 1890, J SOC CHEM IND LOND, P455
[9]  
KALLENBERG M, 2008, P SOC PHOTO-OPT INS, P8
[10]  
Kallenberg M, 2008, LECT NOTES COMPUT SC, V5116, P343, DOI 10.1007/978-3-540-70538-3_48