A Monte Carlo based analytic model of the in-room neutron ambient dose equivalent for a Mevion gantry-mounted passively scattered proton system

被引:4
作者
Baradaran-Ghahfarokhi, Milad [1 ]
Reynoso, Francisco [1 ]
Darafsheh, Arash [1 ]
Sun, Baozhou [1 ]
Prusator, Michael T. [1 ]
Mutic, Sasa [1 ]
Zhao, Tianyu [1 ]
机构
[1] Washington Univ, Dept Radiat Oncol, St Louis, MO 63110 USA
关键词
neutron ambient dose equivalent; Monte Carlo simulation; analytic model; passively scattered proton; shielding; RADIATION; RADIOTHERAPY; PHOTON;
D O I
10.1088/1361-6498/abaff4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The goal of this study was to develop a Monte Carlo (MC)-based analytical model that can predict the in-room ambient dose equivalent from a Mevion gantry-mounted passively scattered proton system. The Mevion S250 and treatment vault were simulated using the MCNPX MC code. The results of the in-room neutron dose measurements, using an FHT 762 WENDI-II detector, were employed to benchmark the MC-derived values. After tuning the MCNPX MC code, for the same beam delivery parameters, the code was used to calculate the neutron spectra and ambient dose equivalent in the vault and at varying angles from the isocenter. Then, based on the calculations, an analytical model was reconstructed and data were fitted to derive the model parameters at 95% confidence intervals (CI). The MCNPX codes were tuned to within about 19% of the measured values for most of the measurements in the vault. For the maze, up to 0.08 mSv Gy(-1)discrepancies were found between the experimental measurements and MCNPX calculated results. The analytical model showed up to 18% discrepancy for distances between 100 and 600 cm from the isocenter compared to the MC calculations. The model may underestimate the neutron ambient dose equivalent up to 21% for distances less than 100 cm from the isocenter. The proposed analytical model can be used to estimate the contribution of the secondary neutron dose from the Mevion S250 for the design of local shielding inside the proton therapy treatment vault.
引用
收藏
页码:980 / 996
页数:17
相关论文
共 28 条
  • [1] [Anonymous], 2017, gridExtra: miscellaneous functions for "Grid" graphics
  • [2] Neutron equivalent doses and associated lifetime cancer incidence risks for head & neck and spinal proton therapy
    Athar, Basit S.
    Paganetti, Harald
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (16) : 4907 - 4926
  • [3] Normal tissue complication probability models for severe acute radiological lung injury after radiotherapy for lung cancer
    Avanzo, M.
    Trovo, M.
    Furlan, C.
    Barresi, L.
    Linda, A.
    Stancanello, J.
    Andreon, L.
    Minatel, E.
    Bazzocchi, M.
    Trovo, M. G.
    Capra, E.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (01): : 1 - 8
  • [4] A Monte Carlo-based analytic model of neutron dose equivalent for a mevion gantry-mounted passively scattered proton system for craniospinal irradiation
    Baradaran-Ghahfarokhi, Milad
    Reynoso, Francisco
    Sun, Baozhou
    Darafsheh, Arash
    Prusator, Michael T.
    Mutic, Sasa
    Zhao, Tianyu
    [J]. MEDICAL PHYSICS, 2020, 47 (09) : 4509 - 4521
  • [5] Sensitivity analysis of Monte Carlo model of a gantry-mounted passively scattered proton system
    Baradaran-Ghahfarokhi, Milad
    Reynoso, Francisco
    Prusator, Michael T.
    Sun, Baozhou
    Zhao, Tianyu
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (02): : 26 - 37
  • [6] Uncertainties and correction methods when modeling passive scattering proton therapy treatment heads with Monte Carlo
    Bednarz, Bryan
    Lu, Hsiao-Ming
    Engelsman, Martijn
    Paganetti, Harald
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (09) : 2837 - 2854
  • [7] Evaluation of neutron dose equivalent from the Mevion S250 proton accelerator: measurements and calculations
    Chen, Kuan Ling
    Bloch, Charles D.
    Hill, Patrick M.
    Klein, Eric E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (24) : 8709 - 8723
  • [8] Equivalent dose and effective dose from stray radiation during passively scattered proton radiotherapy for prostate cancer
    Fontenot, Jonas
    Taddei, Phillip
    Zheng, Yuanshui
    Mirkovic, Dragan
    Jordan, Thomas
    Newhauser, Wayne
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (06) : 1677 - 1688
  • [9] ANALYTICAL MODEL TO ESTIMATE EQUIVALENT DOSE FROM INTERNAL NEUTRONS IN PROTON THERAPY OF CHILDREN WITH INTRACRANIAL TUMORS
    Gallagher, Kyle J.
    Taddei, Phillip J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2019, 183 (04) : 460 - 468
  • [10] Independent application of an analytical model for secondary neutron equivalent dose produced in a passive-scattering proton therapy treatment unit
    Gallagher, Kyle J.
    Taddei, Phillip J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15)