Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor

被引:93
作者
DeMarco, DR
Saaski, EW
McCrae, DA
Lim, DV [1 ]
机构
[1] Univ S Florida, Dept Biol, Tampa, FL 33620 USA
[2] Res Int, Woodinville, WA 98072 USA
关键词
D O I
10.4315/0362-028X-62.7.711
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A portable fiber-optic biosensor was used to detect Escherichia coli O157:H7 in seeded ground beef samples. The principle of the system is a sandwich immunoassay using cyanine 5 dye-labeled polyclonal anti-E. cold O157:H7 antibodies for generation of a specific fluorescent signal. Signal acquisition is effected by launching light from a 635-nm diode laser into a dual tapered 600-mu m silica fiber. Fluorescent molecules within approximately 100 nm of the fiber surface are excited by the evanescent field, and a portion of the emission recouples into the fiber. A photodiode allows for quantitation of the collected emission light at wavelengths of 670 to 710 nm. Biotin-avidin interactions are used to attach polyclonal antibodies specific for E. coli O157:H7 to the final 7.5 cm of the fiber probe. The biosensor was able to detect E. coli O157:H7 to 3 to 30 CFU/ mi in seeded ground beef samples. The reaction was highly specific. Signals with Listeria monocytogenes, Salmonella Typhimurium, or E. coli nonO157:H7 were 2 to 3% of those observed with a similar concentration of E. coli O157:H7. Assays were conducted at or near real-time with results obtained within 20 min of sampling.
引用
收藏
页码:711 / 716
页数:6
相关论文
共 25 条
[1]   A FIBER OPTIC BIOSENSOR - COMBINATION TAPERED FIBERS DESIGNED FOR IMPROVED SIGNAL ACQUISITION [J].
ANDERSON, GP ;
GOLDEN, JP ;
LIGLER, FS .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) :249-256
[2]   Assay development for a portable fiberoptic biosensor [J].
Anderson, GP ;
Breslin, KA ;
Ligler, FS .
ASAIO JOURNAL, 1996, 42 (06) :942-946
[3]   A MULTISTATE OUTBREAK OF ESCHERICHIA-COLI-O157-H7 ASSOCIATED BLOODY DIARRHEA AND HEMOLYTIC-UREMIC-SYNDROME FROM HAMBURGERS - THE WASHINGTON EXPERIENCE [J].
BELL, BP ;
GOLDOFT, M ;
GRIFFIN, PM ;
DAVIS, MA ;
GORDON, DC ;
TARR, PI ;
BARTLESON, CA ;
LEWIS, JH ;
BARRETT, TJ ;
WELLS, JG ;
BARON, R ;
KOBAYASHI, J .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (17) :1349-1353
[4]   EVALUATION OF METHODS FOR THE ISOLATION AND DETECTION OF ESCHERICHIA-COLI O157 IN MINCED BEEF [J].
BENNETT, AR ;
MACPHEE, S ;
BETTS, RP .
LETTERS IN APPLIED MICROBIOLOGY, 1995, 20 (06) :375-379
[5]   USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES [J].
BHATIA, SK ;
SHRIVERLAKE, LC ;
PRIOR, KJ ;
GEORGER, JH ;
CALVERT, JM ;
BREDEHORST, R ;
LIGLER, FS .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :408-413
[6]   DETECTION OF YERSINIA-PESTIS FRACTION-1 ANTIGEN WITH A FIBER OPTIC BIOSENSOR [J].
CAO, LK ;
ANDERSON, GP ;
LIGLER, FS ;
EZZELL, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (02) :336-341
[7]   Portable multichannel fiber optic biosensor for field detection [J].
Golden, JP ;
Saaski, EW ;
ShriverLake, LC ;
Anderson, GP ;
Ligler, FS .
OPTICAL ENGINEERING, 1997, 36 (04) :1008-1013
[8]   THE EPIDEMIOLOGY OF INFECTIONS CAUSED BY ESCHERICHIA-COLI O157-H7, OTHER ENTEROHEMORRHAGIC ESCHERICHIA-COLI, AND THE ASSOCIATED HEMOLYTIC UREMIC SYNDROME [J].
GRIFFIN, PM ;
TAUXE, RV .
EPIDEMIOLOGIC REVIEWS, 1991, 13 :60-98
[9]  
Hitchins A. D., 1995, Bacteriological Analytical Manual, BAM-8
[10]  
HNATOWICH DJ, 1987, J NUCL MED, V28, P1294