Three-dimensional Observation of Nonmetallic Inclusion Clusters in Solid Metal by X-ray Micro-CT

被引:18
作者
Li, Tao [1 ,2 ]
Shimasaki, Shin-ichi [1 ,3 ]
Taniguchi, Shoji [1 ]
Narita, Shunsuke [1 ,4 ]
Uesugi, Kentaro [5 ]
机构
[1] Tohoku Univ, Grad Sch Environm Studies, Aoba Ku, 6-6-20 Aoba Yama, Sendai, Miyagi 9808579, Japan
[2] Norwegian Univ Sci & Technol, Kolbjorn Hejes 5 1B, N-7491 Trondheim, Norway
[3] Kagawa Coll, Dept Electromech Syst Engn, Natl Inst Technol, 335 Chokushi Cho, Takamatsu, Kagawa 7618058, Japan
[4] Daido Steel Co Ltd, Higashi Ku, 1-10,1 Chome Higashisakura, Nagoya, Aichi 4618581, Japan
[5] Japan Synchrotron Radiat Res Inst JASRI Spring 8, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
基金
日本学术振兴会;
关键词
inclusion; steel; alumina; cluster; three-dimensional; X-ray; micro-CT; DIFFUSION-LIMITED AGGREGATION; PARTICLE COAGULATION; ALUMINA CLUSTERS; MOLTEN-METAL; TOMOGRAPHY; MODEL; FLOTATION;
D O I
10.2355/isijinternational.ISIJINT-2016-218
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
In this study, we developed a method of observing three-dimensional (3D) inclusion clusters in metal. The theory of X-ray micro-computed tomography (CT) is generally introduced. The criteria on determining the sample size and energy of X-ray beam is set according to the characteristics of the beamline BL20XU available at Spring-8, which is the largest synchrotron radiation facility. The Al-TiB2 and Al-SiC system were measured by the X-ray micro-CT available in beamline BL20XU at Spring-8. The determination of the sample size the energy of X-ray beam are discussed on basis of the X-ray linear attenuation coefficient (LAC) and the transmission rate of Al-TiB2 and Al-SIC system. The limitation of the charge coupled device (CCD) camera, such as spatial resolution and observing field, are taken into consideration as well. Phase retrieval method is applied to reduce the noises of tomographic images for Al-SiC system due to its poor contrast. The 3D particle clusters of TiB2 and SiC are reconstructed by self-developed program. The fractal dimension of TiB2 and SiC clusters are calculated around 2.7. The feasibility of observing alumina cluster in steel is discussed on basis of the latest capability of beamline BL20XU at Spring-8.
引用
收藏
页码:1989 / 1995
页数:7
相关论文
共 25 条
[1]  
[Anonymous], SPACE FILLING CURVES
[2]  
[Anonymous], 2003, FRACTAL GEOMETRY MAT
[3]   Model Experiment on Inclusion Removal by Bubble Flotation Accompanied by Particle Coagulation in Turbulent Flow [J].
Arai, Hirotada ;
Matsumoto, Katsutoshi ;
Shimasaki, Shin-ichi ;
Taniguchi, Shoji .
ISIJ INTERNATIONAL, 2009, 49 (07) :965-974
[4]   2D and 3D X-ray phase retrieval of multi-material objects using a single defocus distance [J].
Beltran, M. A. ;
Paganin, D. M. ;
Uesugi, K. ;
Kitchen, M. J. .
OPTICS EXPRESS, 2010, 18 (07) :6423-6436
[5]   Characterization of internal damage in a MMCp using x-ray synchrotron phase contrast microtomography [J].
Buffière, JY ;
Maire, E ;
Cloetens, P ;
Lormand, G ;
Fougères, R .
ACTA MATERIALIA, 1999, 47 (05) :1613-1625
[6]  
Deans S, 1983, RADON TRANSFORM SOME
[7]   Measurement of the 2-dimensional fractal dimensions of alumina clusters formed in an ultra low carbon steel melt during RH process [J].
Doo, Won-Chul ;
Kim, Dong-Yong ;
Kang, Soo-Chang ;
Yl, Kyung-Woo .
ISIJ INTERNATIONAL, 2007, 47 (07) :1070-1072
[8]  
Duhamel, 1990, IEEE SIGNAL P SOC, V19, P259
[9]   Three-dimensional quantitative analysis of polymer foams from synchrotron radiation x-ray microtomography [J].
Elmoutaouakkil, A ;
Fuchs, G ;
Bergounhon, P ;
Péres, R ;
Peyrin, F .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (10A) :A37-A43
[10]   Rapid quantitative phase imaging using the transport of intensity equation [J].
Gureyev, TE ;
Nugent, KA .
OPTICS COMMUNICATIONS, 1997, 133 (1-6) :339-346