Improved imaging of intrahepatic colorectal metastases with 18F-fluorodeoxyglucose respiratory-gated positron emission tomography

被引:14
作者
Fin, Loic [1 ,2 ]
Daouk, Joel [2 ,5 ]
Bailly, Pascal [2 ]
Slama, Jerome [2 ]
Morvan, Julie [2 ,5 ]
El Esper, Isabelle [2 ,5 ]
Regimbeau, Jean-Marc [3 ,5 ]
Chatelain, Denis [4 ,5 ]
Diouf, Momar [1 ]
Meyer, Marc-Etienne [2 ,5 ]
机构
[1] Amiens Univ, Med Ctr, Dept Clin Trial & Innovat, Amiens, France
[2] Amiens Univ, Med Ctr, Dept Nucl Med, Amiens, France
[3] Amiens Univ, Med Ctr, Dept Visceral & Digest Surg, Amiens, France
[4] Amiens Univ, Med Ctr, Dept Pathol, Amiens, France
[5] Jules Verne Univ Picardy, Fac Med, Amiens, France
关键词
colorectal liver metastases; F-18-fluorodeoxyglucose positron emission tomography/computed tomography; respiratory motion; LIVER METASTASES; ATTENUATION CORRECTION; F-18-FDG PET; RECONSTRUCTION; MOTION; CANCER; CT; PERFORMANCE; SELECTION; MODEL;
D O I
10.1097/MNM.0b013e328351fce8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background In F-18-fluorodeoxyglucose PET/CT, respiratory motion induces bias in image interpretations (i.e. organ misregistration or lesion omission/underestimation). Objective The present study applied our custom gating method (referred to as 'CT-based gated PET' and that has already been validated by our research group) to PET imaging of the liver and compared its per lesion sensitivity with that of standard clinical (i.e. ungated) PET. Methods A total of 13 patients scheduled for liver surgery were referred to our department for PET/CT imaging. Each patient underwent both ungated and CT-based gated PET imaging protocols. Two independent, blinded observers interpreted the two sets of PET images and reached a consensus when necessary. Image interpretations were combined with histological analysis and/or intraoperative ultrasound examination to compute each method's per lesion sensitivity and true positive fraction. Analyses were also performed by considering lesions according to their size (longest axis over 10 mm or over 15 mm). Results Forty-eight lesions were confirmed by pathology reports. When considering all the uptakes, the ungated and the CT-based gated PET methods had sensitivities of 54.2 and 64.6% (P=0.025) and true positive fractions of 83.9 and 86.1%, respectively. When considering uptakes greater than 10 mm in size, ungated and CT-based gated PET had sensitivities of 74.3 and 88.6% (P=0.025), respectively. For lesions greater than 15 mm in size, the corresponding sensitivities were 85.2 and 100% (P=0.046). Conclusion CT-based gated PET yielded a higher lesion-based sensitivity than routine, ungated PET did. Hence, this method improves the detection of intrahepatic colorectal metastases - especially for lesions that are close in size to the detection limit of the PET gantry. Nucl Med Commun 33:656-662 (c) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:656 / 662
页数:7
相关论文
共 38 条
[1]   Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques [J].
Bettinardi, Valentino ;
Picchio, Maria ;
Di Muzio, Nadia ;
Gianolli, Luigi ;
Gilardi, Maria Carla ;
Messa, Cristina .
RADIOTHERAPY AND ONCOLOGY, 2010, 96 (03) :311-316
[2]  
Brambilla M, 2005, J NUCL MED, V46, P2083
[3]  
Carnaghi C, 2007, NUCL MED REV, V10, P12
[4]   Implementation of an Automated Respiratory Amplitude Gating Technique for PET/CT: Clinical Evaluation [J].
Chang, Guoping ;
Chang, Tingting ;
Pan, Tinsu ;
Clark, John W., Jr. ;
Mawlawi, Osama R. .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (01) :16-24
[5]   The impact of 18F-FDG PET/CT in patients with liver metastases [J].
Chua, Siew C. ;
Groves, Ashley M. ;
Kayani, Irfan ;
Menezes, Leon ;
Gacinovic, Svetislav ;
Du, Yong ;
Bomanji, Jamshed B. ;
Ell, Peter J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (12) :1906-1914
[6]  
Clifford Mark A, 2002, Comput Aided Surg, V7, P291, DOI 10.1002/igs.10049
[7]   Fast reconstruction of 3D PET data with accurate statistical modeling [J].
Comtat, C ;
Kinahan, PE ;
Defrise, M ;
Michel, C ;
Townsend, DW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :1083-1089
[8]   Respiratory-Gated Positron Emission Tomography and Breath-Hold Computed Tomography Coupling to Reduce the Influence of Respiratory Motion: Methodology and Feasibility [J].
Daouk, J. ;
Fin, L. ;
Bailly, P. ;
Meyer, M. -E. .
ACTA RADIOLOGICA, 2009, 50 (02) :144-155
[9]  
Daouk J, 2008, 5 IEEE INT S BIOM IM, P1323
[10]   Improved attenuation correction via appropriate selection of respiratory-correlated PET data [J].
Daouk, Joel ;
Fin, Loic ;
Bailly, Pascal ;
Meyer, Marc-Etienne .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2008, 92 (01) :90-98