Effect of atmospheric condition and ammonia mass fraction on the combined cycle for power and cooling using ammonia water mixture in bottoming cycle

被引:9
作者
Maheshwari, Mayank [1 ]
Singh, Onkar [2 ]
机构
[1] AKTU, Lucknow, Uttar Pradesh, India
[2] HBTU, Kanpur, Uttar Pradesh, India
关键词
Combined cycle; Closed loop cooling; Ammonia mass fraction; Heat recovery vapor generator; STEAM COMBINED-CYCLE; EXERGY ANALYSIS; GAS-TURBINES; REHEAT; PERFORMANCE; ENERGY; PLANT; OPTIMIZATION; SYSTEM; HRSG;
D O I
10.1016/j.energy.2018.01.131
中图分类号
O414.1 [热力学];
学科分类号
摘要
Gas/steam combined cycle power plants are being extensively used for power generation due to their better performance as compared to gas turbine based or steam turbine based power plants operating in isolation. These combined cycle power plants have natural aspiration in compressors where the state of ambient air entering it, significantly affects the work requirement of compressors and thus affects the overall combined cycle power plant performance. It is felt that in tropical countries with significant seasonal variations, when the atmospheric temperatures become quite high during some months in a calendar year, the cooling of ambient air before entering compressor using the energy available in combined cycle power plant may help in improving the overall plant performance. In view of this a combined cycle with ability of producing power and provision of simultaneous cooling of air entering the compressor and cooling of gas turbine blades through ammonia water mixture and steam using closed loop cooling scheme has been studied in this paper. A comparative analysis of the combined cycle's considered shows that for a cycle pressure ratio of 40 and turbine inlet temperature of 2000K maximum work of 2093 kJ/kg of compressed air is obtained for ammonia mass fraction of 0.6 for the combined cycle using only ammonia water mixture as coolant where as maximum first law efficiency and second law efficiency of 62.6% and 59.67% are being achieved for ammonia mass fraction of 0.7, for the same configuration and at an ambient temperature of 30 degrees C. Cooling load of 22 kW is observed to be maximum for the configuration using steam and ammonia water mixture as coolant and for an ambient temperature of 50 degrees C at the cycle pressure ratio of 40, turbine inlet temperature of 2000K and ammonia mass fraction of 0.6. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:585 / 604
页数:20
相关论文
共 46 条
[31]   The advanced cooling technology for the 1500 degrees C class gas turbines: Steam-cooled vanes and air-cooled blades [J].
Nomoto, H ;
Koga, A ;
Ito, S ;
Fukuyama, Y ;
Otomo, F ;
Shibuya, S ;
Sato, M ;
Kobayashi, Y ;
Matsuzaki, H .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1997, 119 (03) :624-632
[32]   SIMPLE FUNCTIONS FOR FAST CALCULATIONS OF SELECTED THERMODYNAMIC PROPERTIES OF THE AMMONIA-WATER SYSTEM [J].
PATEK, J ;
KLOMFAR, J .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (04) :228-234
[33]  
Pattanayak Lalatendu, ENV PROGR SUSTAINABL, DOI [10.1002/ep, DOI 10.1002/EP]
[34]   Optimum operating conditions for a combined power and cooling thermodynamic cycle [J].
Sadrameli, S. M. ;
Goswami, D. Y. .
APPLIED ENERGY, 2007, 84 (03) :254-265
[35]   Thermoeconomic investigation of basic and intercooled gas turbine based power utilities incorporating air-film blade cooling [J].
Sahu, Mithilesh Kumar ;
Sanjay .
JOURNAL OF CLEANER PRODUCTION, 2018, 170 :842-856
[36]   Influence of different means of turbine blade cooling on the thermodynamic performance of combined cycle [J].
Sanjay ;
Singh, Onkar ;
Prasad, B. N. .
APPLIED THERMAL ENGINEERING, 2008, 28 (17-18) :2315-2326
[37]   Exergy and Energy Analysis of Combined Cycle systems with Different Bottoming Cycle Configurations [J].
Sanjay .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (08) :899-912
[38]   Energy and exergy analysis of steam cooled reheat gas-steam combined cycle [J].
Sanjay, Y. ;
Singh, Onkar ;
Prasad, B. N. .
APPLIED THERMAL ENGINEERING, 2007, 27 (17-18) :2779-2790
[39]   Parametric optimization of vapor power and cooling cycle [J].
Shankar, R. ;
Srinivas, T. .
4 INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESEARCH (ICAER 2013), 2014, 54 :135-141
[40]   Exergy analysis of dual pressure HRSG for different dead states and varying steam generation states in gas/steam combined cycle power plant [J].
Sharma, Meeta ;
Singh, Onkar .
APPLIED THERMAL ENGINEERING, 2016, 93 :614-622