Determination of the enantiomeric composition of a new insulin sensitizer in plasma samples from non-clinical and clinical investigations using chiral HPLC with electrospray tandem mass spectrometric detection

被引:4
|
作者
Lausecker, B [1 ]
Fischer, G [1 ]
机构
[1] F Hoffmann La Roche Ltd, Pharmaceut Div, Non Clin Drug Safety, CH-4070 Basel, Switzerland
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2006年 / 835卷 / 1-2期
关键词
ionspray; chiral drug assay; glitazones; interconversion;
D O I
10.1016/j.jchromb.2006.03.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two drug assays were developed and applied to assess the enantiomeric composition of an insulin sensitizer drug in plasma after administration of its racemate to man, and in human and animal plasma and serum samples generated after in vitro experiments. The sample preparation for the assays consisted either of protein precipitation and column-switching, or liquid-liquid extraction and direct injection. Subsequently, both assays employed chiral HPLC coupled to atmospheric pressure ionization mass spectrometry. An interconversion of the racemate to a mixture enriched with the (+)-enantiomer could be confirmed for all species and biological matrices. The individual enantiomers could be quantified in the concentration range 0.5-500ng/ml, starting with a 100-mu l plasma aliquot. Inter- and intra-assay precision and accuracy were in the range 0.1-7.9 and 88.8-106.0%, respectively. Run times of 5 min for a single sample allows the analysis of more than 200 samples overnight. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 9 条