IVUSAngio Tool: A publicly available software for fast and accurate 3D reconstruction of coronary arteries

被引:17
作者
Doulaverakis, Charalampos [1 ]
Tsampoulatidis, Ioannis [1 ]
Antoniadis, Antonios P. [2 ]
Chatzizisis, Yiannis S. [2 ]
Giannopoulos, Andreas [2 ]
Kompatsiaris, Ioannis [1 ]
Giannoglou, George D. [2 ]
机构
[1] Ctr Res & Technol Hellas, Inst Informat Technol, Thessaloniki 57001, Greece
[2] Aristotle Univ Thessaloniki, Cardiovasc Engn & Atherosclerosis Lab, Sch Med, AHEPA Univ Hosp,Dept Cardiol 1, Thessaloniki 54636, Greece
关键词
Coronary angiography; Intravascular ultrasound; 3D reconstruction; Software; ENDOTHELIAL SHEAR-STRESS; CORRECT 3-DIMENSIONAL RECONSTRUCTION; INTRAVASCULAR ULTRASOUND IMAGES; IN-VIVO VALIDATION; IVUS ANGUS; ANGIOGRAPHY; ATHEROSCLEROSIS; SEGMENTATION; FUSION; PLAQUE;
D O I
10.1016/j.compbiomed.2013.08.013
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
There is an ongoing research and clinical interest in the development of reliable and easily accessible software for the 3D reconstruction of coronary arteries. In this work, we present the architecture and validation of IVUSAngio Tool, an application which performs fast and accurate 3D reconstruction of the coronary arteries by using intravascular ultrasound (IVUS) and biplane angiography data. The 3D reconstruction is based on the fusion of the detected arterial boundaries in IVUS images with the 3D IVUS catheter path derived from the biplane angiography. The IVUSAngio Tool suite integrates all the intermediate processing and computational steps and provides a user-friendly interface. It also offers additional functionality, such as automatic selection of the end-diastolic IVUS images, semi-automatic and automatic IVUS segmentation, vascular morphometric measurements, graphical visualization of the 3D model and export in a format compatible with other computer-aided design applications. Our software was applied and validated in 31 human coronary arteries yielding quite promising results. Collectively, the use of IVUSAngio Tool significantly reduces the total processing time for 3D coronary reconstruction. IVUSAngio Tool is distributed as free software, publicly available to download and use. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1793 / 1803
页数:11
相关论文
共 38 条
[1]  
[Anonymous], 1978, A Practical Guide to Splines
[2]  
[Anonymous], 2001, Robotica, DOI DOI 10.1017/S0263574700223217
[3]  
Bom N, 1998, Eur J Ultrasound, V7, P9, DOI 10.1016/S0929-8266(98)00007-X
[4]   ANGIOCARE: An automated system for fast three-dimensional coronary reconstruction by integrating angiographic and intracoronary ultrasound data [J].
Bourantas, Christos V. ;
Kalatzis, Fanis G. ;
Papafaklis, Michail I. ;
Fotiadis, Dimitrios I. ;
Tweddel, Ann C. ;
Kourtis, Iraklis C. ;
Katsouras, Christos S. ;
Michalis, Lampros K. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (02) :166-175
[5]   Coronary hemodynamics and atherosclerotic wall stiffness: A vicious cycle [J].
Chatzizisis, Yiannis S. ;
Giannoglou, George D. .
MEDICAL HYPOTHESES, 2007, 69 (02) :349-355
[6]   Role of endothelial shear stress in the natural history of coronary atherosclerosis and vascular remodeling - Molecular, cellular, and vascular behavior [J].
Chatzizisis, Yiannis S. ;
Coskun, Ahmet Umit ;
Jonas, Michael ;
Edelman, Elazer R. ;
Feldman, Charles L. ;
Stone, Peter H. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (25) :2379-2393
[7]   In-vivo accuracy of geometrically correct three-dimensional reconstruction of human coronary arteries: is it influenced by certain parameters? [J].
Chatzizisis, Yiannis S. ;
Giannoglou, George D. ;
Matakos, Antonis ;
Basdekidou, Chrysanthi ;
Sianos, George ;
Panagiotou, Alexandros ;
Dimakis, Christos ;
Parcharidis, George E. ;
Louridas, George E. .
CORONARY ARTERY DISEASE, 2006, 17 (06) :545-551
[8]   Reproducibility of coronary lumen, plaque, and vessel wall reconstruction and of endothelial shear stress measurements in vivo in humans [J].
Coskun, AU ;
Yeghiazarians, Y ;
Kinlay, S ;
Clark, ME ;
Ilegbusi, OJ ;
Wahle, A ;
Sonka, M ;
Popma, JJ ;
Kuntz, RE ;
Feldman, CL ;
Stone, PH .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (01) :67-78
[9]   Accurate three-dimensional reconstruction of intravascular ultrasound data - Spatially correct three-dimensional reconstructions [J].
Evans, JL ;
Ng, KH ;
Wiet, SG ;
Vonesh, MJ ;
Burns, WB ;
Radvany, MG ;
Kane, BJ ;
Davidson, CJ ;
Roth, SI ;
Kramer, BL ;
Meyers, SN ;
McPherson, DD .
CIRCULATION, 1996, 93 (03) :567-576
[10]  
Exarchos TP, 2011, IEEE ENG MED BIO, P838, DOI 10.1109/IEMBS.2011.6089867