The effect of mannosylation of liposome-encapsulated indocyanine green on imaging of sentinel lymph node

被引:34
作者
Jeong, Hwan-Seok [1 ,2 ,3 ,4 ,5 ]
Lee, Chang-Moon [6 ]
Cheong, Su-Jin [1 ,2 ,3 ,4 ,5 ]
Kim, Eun-Mi [1 ,2 ,3 ,4 ,5 ]
Hwang, Hyosook [1 ,2 ,3 ,4 ,5 ]
Na, Kyung Sook [1 ,2 ,3 ,4 ,5 ]
Lim, Seok Tae [1 ,2 ,3 ,4 ,5 ]
Sohn, Myung-Hee [1 ,2 ,3 ,4 ,5 ]
Jeong, Hwan-Jeong [1 ,2 ,3 ,4 ,5 ]
机构
[1] Chonbuk Natl Univ Med Sch & Hosp, Dept Nucl Med, Jeonju, Jeonbuk, South Korea
[2] Chonbuk Natl Univ Med Sch & Hosp, Biomed Res Inst, Jeonju, Jeonbuk, South Korea
[3] Chonbuk Natl Univ Med Sch & Hosp, Cyclotron Res Ctr, Jeonju, Jeonbuk, South Korea
[4] Chonbuk Natl Univ Med Sch & Hosp, Inst Med Sci, Jeonju, Jeonbuk, South Korea
[5] Chonbuk Natl Univ Med Sch & Hosp, Mol Imaging & Therapeut Med Res Ctr, Jeonju, Jeonbuk, South Korea
[6] Chonnam Natl Univ, Dept Biomed Engn, Yeosu, Jeonnam, South Korea
基金
新加坡国家研究基金会;
关键词
Indocyanine green; liposome; mannosylation; sentinel lymph node; FLUORESCENCE; MACROPHAGES; DELIVERY; NANOPARTICLES; DOXORUBICIN; SYSTEM; LECTIN; CELLS;
D O I
10.3109/08982104.2013.801488
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The imaging of sentinel lymph nodes (SLN) has been researched for its role in assessing cancer progression and postsurgical lymphedema. Indocyanine green (ICG) is a near-infrared (NIR) optical dye that has been approved by the Food and Drug Administration. It is known that liposome-encapsulated ICG (LP-ICG) has improved stability and fluorescence signal compared with ICG. We designed mannosylated liposome-encapsulated ICG (M-LP-ICG) as an optical contrast agent for SLN. M-LP-ICG has a higher UV absorbance spectrum and fluorescence intensity than LP-ICG. The stability of M-LP-ICG measured in 50% fetal bovine serum solution by a dialysis method was better than that of LP-ICG. M-LP-ICG demonstrated a high uptake in RAW 264.7 macrophage cell because the density of mannose is high. There were differences between M-LP-ICG and glucosylated liposome-encapsulated ICG (G-LP-ICG), which are geometrical isomers. The result of an inhibition study of M-LP-ICG showed a statistically significant decrease in uptake in RAW 264.7 cells after either co-treatment or pre-treatment with D-(+)-mannose as an inhibitor. Results from an in vitro experiment demonstrated that M-LP-ICG was specifically taken up by macrophage cells through the mannose receptor on its surface. The time-series images acquired from a normal mouse model after subcutaneous injection showed that the signal from M-LP-ICG in SLN and other organs appeared early and disappeared quickly in comparison with signals from LP-ICG. Not only the sentinel but also the draining lymph nodes were observed partly in M-LP-ICG. M-LP-ICG appears to increase the specificity of uptake and retention in macrophages, making it a good candidate contrast agent for an optic imaging system for SLN and the lymphatic system.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 36 条
[21]   Indocyanine green:: Physicochemical factors affecting its fluorescence in vivo [J].
Mordon, S ;
Devoisselle, JM ;
Soulie-Begu, S ;
Desmettre, T .
MICROVASCULAR RESEARCH, 1998, 55 (02) :146-152
[22]  
Ohnishi S, 2005, MOL IMAGING, V4, P172
[23]   Involvement of serum mannan binding proteins and mannose receptors in uptake of mannosylated liposomes by macrophages [J].
Opanasopit, P ;
Higuchi, Y ;
Kawakami, S ;
Yamashita, F ;
Nishikawa, M ;
Hashida, M .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2001, 1511 (01) :134-145
[24]   Quantitative Imaging of Lymphatic Function with Liposomal Indocyanine Green [J].
Proulx, Steven T. ;
Luciani, Paola ;
Derzsi, Stefanie ;
Rinderknecht, Matthias ;
Mumprecht, Viviane ;
Leroux, Jean-Christophe ;
Detmar, Michael .
CANCER RESEARCH, 2010, 70 (18) :7053-7062
[25]   Lymphatic imaging in humans with near-infrared fluorescence [J].
Rasmussen, John C. ;
Tan, I-Chih ;
Marshall, Milton V. ;
Fife, Caroline E. ;
Sevick-Muraca, Eva M. .
CURRENT OPINION IN BIOTECHNOLOGY, 2009, 20 (01) :74-82
[26]   Assessing liver function [J].
Sakka, Samir G. .
CURRENT OPINION IN CRITICAL CARE, 2007, 13 (02) :207-214
[27]   Fluorescent Nanoprobes as a Biomarker for Increased Vascular Permeability: Implications in Diagnosis and Treatment of Cancer and Inflammation [J].
Sandanaraj, Britto S. ;
Gremlich, Hans-Ulrich ;
Kneuer, Rainer ;
Dawson, Janet ;
Wacha, Stefan .
BIOCONJUGATE CHEMISTRY, 2010, 21 (01) :93-101
[28]   Indocyanine green-loaded biodegradable nanoparticles: preparation, physicochemical characterization and in vitro release [J].
Saxena, V ;
Sadoqi, M ;
Shao, J .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2004, 278 (02) :293-301
[29]   Degradation kinetics of indocyanine green in aqueous solution [J].
Saxena, V ;
Sadoqi, M ;
Shao, J .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2003, 92 (10) :2090-2097
[30]   Fluorescence and absorption contrast mechanisms for biomedical optical imaging using frequency-domain techniques [J].
SevickMuraca, EM ;
Lopez, G ;
Reynolds, JS ;
Troy, TL ;
Hutchinson, CL .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1997, 66 (01) :55-64