Femtosecond Lasers in Ophthalmology

被引:230
|
作者
Soong, H. Kaz [1 ]
Malta, Joao Baptista [1 ,2 ]
机构
[1] Univ Michigan, WK Kellogg Eye Ctr, Dept Ophthalmol & Visual Sci, Sch Med, Ann Arbor, MI 48105 USA
[2] Div Cornea & External Dis, Dept Ophthalmol, Sao Paulo, Brazil
关键词
POSTERIOR LAMELLAR KERATOPLASTY; IN-SITU KERATOMILEUSIS; SHAPED PENETRATING KERATOPLASTY; EYE BANK EYES; REFRACTIVE SURGERY; ENDOTHELIAL KERATOPLASTY; FLAP CREATION; INTRALASE; ANTERIOR; MICROKERATOME;
D O I
10.1016/j.ajo.2008.08.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To provide an update and review of femtosecond (FS) lasers in clinical ophthalmology. DESIGN: Perspective, literature review, and commentary. METHODS: Selected articles from the literature and the authors' clinical and laboratory studies. RESULTS: The FS laser employs near-infrared pulses to cut tissue with minimal collateral tissue damage. Although its major use at present is in the cutting of laser in situ keratomileusis flaps, the laser has proven its versatility in laser,assisted anterior and posterior lamellar keratoplasty, cutting of donor buttons in endothelial keratoplasty, customized trephination in penetrating keratoplasty, tunnel creation for intracorneal ring segments, astigmatic keratotomy, and corneal biopsy. Current laboratory studies include all-FS laser refractive keratomileusis sans flap, cutting corneal pockets for insertion of biopolymer keratoprostheses, noninvasive transscleral glaucoma surgery, retinal imaging and photodisruption, presbyopia surgery, and anterior tens capsulorrhexis. CONCLUSIONS: Advances in ultra,fast laser technology continue to improve the surgical safety, efficiency, speed, and versatility of FS lasers in ophthalmology. (Am J Ophthalmol 2009;147:189-197. (C) 2009 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [31] Femtosecond and excimer laser-assisted endothelial keratoplasty (FELEK): A new technique of endothelial transplantation
    Trinh, L.
    Saubamea, B.
    Auclin, F.
    Denoyer, A.
    Lai-Kuen, R.
    El Hamdaoui, M.
    Labbe, A.
    Despiau, M-C.
    Brignole-Baudouin, F.
    Baudouin, C.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2014, 37 (03): : 211 - 219
  • [32] Endothelial Approach Ultrathin Corneal Grafts Prepared by Femtosecond Laser for Descemet Stripping Endothelial Keratoplasty
    Liu, Yu-Chi
    Teo, Ericia Pei Wen
    Adnan, Khadijah Binte
    Yam, Gary Hin Fai
    Peh, Gary Swee Lim
    Tan, Donald T. -H.
    Mehta, Jodhbir S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (12) : 8393 - 8401
  • [33] Intraocular pressure measurements during flap preparation using 2 femtosecond lasers and 1 microkeratome in human donor eyes
    Vetter, Jan M.
    Faust, Melissa
    Gericke, Adrian
    Pfeiffer, Norbert
    Weingaertner, Wolf E.
    Sekundo, Walter
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (11) : 2011 - 2018
  • [34] Preclinical Safety and Efficacy Assessments for Novel Femtosecond Lasers in Corneal Refractive Surgery
    Lisa J. Kloft
    James E. Hill
    Ronika S. Leang
    Arlene E. Gwon
    Ling C. Huang
    Ophthalmology and Therapy, 2022, 11 : 521 - 532
  • [35] Effects of femtosecond and excimer lasers on implanted KAMRA corneal inlay in animal models
    Sammouh, F. K.
    Baban, T. A.
    Dandan, W. N.
    Warrak, E. L.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2017, 40 (05): : 403 - 407
  • [36] Applications of the femtosecond laser in corneal refractive surgery
    Kim, Peter
    Sutton, Gerard L.
    Rootman, David S.
    CURRENT OPINION IN OPHTHALMOLOGY, 2011, 22 (04) : 238 - 244
  • [37] Finite element model of the temperature increase in excised porcine cadaver iris during direct illumination by femtosecond laser pulses
    Sun, Hui
    Kurtz, Ronald M.
    Juhaszh, Tibor
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (07)
  • [38] Simulation of the temperature increase in human cadaver retina during direct illumination by 150-kHz femtosecond laser pulses
    Sun, Hui
    Hosszufalusi, Nora
    Mikula, Eric R.
    Juhasz, Tibor
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (10)
  • [39] Interface quality of different corneal lamellar-cut depths for femtosecond laser-assisted lamellar anterior keratoplasty
    Zhang, Chenxing
    Bald, Matthew
    Tang, Maolong
    Li, Yan
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (04) : 827 - 835
  • [40] Moving from a Mechanical Microkeratome to a Femtosecond Laser for LASIK to Correct Astigmatic Patients: Clinical Outcomes of a Retrospective, Consecutive, Comparative Study
    Guber, I.
    Moetteli, L.
    Magnin, L.
    Majo, F.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2013, 230 (04) : 337 - 341