Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts - Comparison of different procedures and different contrast agents

被引:103
作者
Droste, DW
Kriete, JU
Stypmann, J
Castrucci, M
Wichter, T
Tietje, R
Weltermann, B
Young, P
Ringelstein, EB
机构
[1] Univ Munster, Neurol Klin & Poliklin, Dept Neurol, D-48129 Munster, Germany
[2] Univ Munster, Dept Cardiol & Angiol, D-4400 Munster, Germany
[3] Univ Munster, Inst Arteriosclerosis Res, D-4400 Munster, Germany
关键词
cerebrovascular disorders; cerebral embolism; foramen ovale; patent; ultrasonography;
D O I
10.1161/01.STR.30.9.1827
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Cardiac right-to-left shunts can be identified by transesophageal echocardiography (TEE) and by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and different provocation procedures. Currently, data on an appropriate time window for the appearance of contrast bubbles in the TCD recording after the injection of the contrast medium and the comparison of different provocation maneuvers to increase right-to-left shunting are insufficient. Methods-Forty-six patients were investigated by both TEE and bilateral TCD of the middle cerebral artery. The following protocol with 6 injection modes was applied in a randomized way: (1) injection of 10 mi, of agitated saline without Valsalva maneuver, (2) injection of 10 mt of agitated saline with Valsalva maneuver, (3) injection of 10 mt of a commercial galactose-based contrast agent (Echovist) without Valsalva maneuver, (4) injection of 10 mi, of Echovist with Valsalva maneuver, (5) injection of 10 mt of Echovist with standardized Valsalva maneuver, and (6) injection of 10 mi, of Echovist with coughing. Results-In 20 patients, a right-to-left shunt was demonstrated by TEE and contrast TCD (shunt-positive). Sixteen patients were negative in both investigations, no patient was positive on TEE and negative on TCD, and 10 patients were only positive on at least 1 TCD investigation but negative during TEE. The amount of microbubbles detected in the various tests decreased in the following order: Echovist and Valsalva maneuver, Echovist with coughing, Echovist and standardized Valsalva maneuver, saline with Valsalva maneuver, Echovist, and saline. With a time window of 20 to 25 seconds for the bubbles to appear in the TCD recording and with a sequence of first Echovist and Valsalva maneuver and then Echovist with coughing, all shunts were reliably identified with a specificity of 65% compared with TEE as the traditional gold standard, The time of first microbubble appearance was not helpful to distinguish between shunts detected on TEE and other shunts. Conclusions-TCD performed twice with 2 provocation maneuvers using Echovist is a sensitive method to identify cardiac right-to-left shunts also identified by TEE.
引用
收藏
页码:1827 / 1832
页数:6
相关论文
共 28 条
  • [1] Optimized transcranial Doppler technique for the diagnosis of cardiac right-to-left shunts
    Albert, A
    Muller, HR
    Hetzel, A
    [J]. JOURNAL OF NEUROIMAGING, 1997, 7 (03) : 159 - 163
  • [2] VALIDATION OF TRANSCRANIAL DOPPLER SONOGRAPHY IN THE ASSESSMENT OF PATENT FORAMEN OVALE
    ANZOLA, GP
    RENALDINI, E
    MAGONI, M
    COSTA, A
    COBELLI, M
    GUINDANI, M
    [J]. CEREBROVASCULAR DISEASES, 1995, 5 (03) : 194 - 198
  • [3] COMPARISON OF TRANSESOPHAGEAL AND TRANSTHORACIC ECHOCARDIOGRAPHY WITH CONTRAST AND COLOR-FLOW DOPPLER IN THE DETECTION OF PATENT FORAMEN OVALE
    BELKIN, RN
    POLLACK, BD
    RUGGIERO, ML
    ALAS, LL
    TATINI, U
    [J]. AMERICAN HEART JOURNAL, 1994, 128 (03) : 520 - 525
  • [4] DETECTION OF PATENT FORAMEN OVALE BY CONTRAST TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    CHEN, WJ
    KUAN, PL
    LIEN, WP
    LIN, FY
    [J]. CHEST, 1992, 101 (06) : 1515 - 1520
  • [5] TRANSCRANIAL DOPPLER ULTRASOUND IDENTIFIES PATIENTS WITH RIGHT-TO-LEFT CARDIAC OR PULMONARY SHUNTS
    CHIMOWITZ, MI
    NEMEC, JJ
    MARWICK, TH
    LORIG, RJ
    FURLAN, AJ
    SALCEDO, EE
    [J]. NEUROLOGY, 1991, 41 (12) : 1902 - 1904
  • [6] COMPARISON OF DIAGNOSTIC-TECHNIQUES FOR THE DETECTION OF A PATENT FORAMEN OVALE IN STROKE PATIENTS
    DITULLIO, M
    SACCO, RL
    VENKETASUBRAMANIAN, N
    SHERMAN, D
    MOHR, JP
    HOMMA, S
    [J]. STROKE, 1993, 24 (07) : 1020 - 1024
  • [7] Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Reproducibility, comparison of 2 agents, and distribution of microemboli
    Droste, DW
    Reisener, M
    Kemény, V
    Dittrich, R
    Schulte-Altedorneburg, G
    Stypmann, J
    Wichter, T
    Ringelstein, EB
    [J]. STROKE, 1999, 30 (05) : 1014 - 1018
  • [8] Simultaneous bilateral contrast transcranial doppler monitoring in patients with intracardiac and intrapulmonary shunts
    Horner, S
    Ni, XS
    Weihs, W
    Harb, S
    Augustin, M
    Duft, M
    Niederkorn, K
    [J]. JOURNAL OF THE NEUROLOGICAL SCIENCES, 1997, 150 (01) : 49 - 57
  • [9] HORNER S, 1998, CEREBROVASC DIS, V8, P7
  • [10] A COMPARISON OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY AND TRANSCRANIAL DOPPLER SONOGRAPHY WITH CONTRAST-MEDIUM FOR DETECTION OF PATENT FORAMEN OVALE
    JAUSS, M
    KAPS, M
    KEBERLE, M
    HABERBOSCH, W
    DORNDORF, W
    [J]. STROKE, 1994, 25 (06) : 1265 - 1267