Structural response of ferrocement panels incorporating lightweight expanded clay and perlite aggregates: Experimental, theoretical and statistical analysis

被引:15
作者
Madadi, Amirhossein [1 ]
Tasdighi, Mahdi [1 ]
Eskandari-Naddaf, Hamid [1 ]
机构
[1] Hakim Sabzevari Univ, Dept Civil Engn, Sabzevar, Iran
关键词
Ferrocement panel; Structural response; Lightweight aggregate; Load-deflection behavior; Taguchi; DIGITAL IMAGE CORRELATION; REINFORCED-CONCRETE; FLEXURAL BEHAVIOR; SLAB PANELS; OPTIMIZATION; BRITTLENESS; CAPACITY; PLATES; MODEL; STEEL;
D O I
10.1016/j.engstruct.2019.03.038
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Structural response of lightweight ferrocement panels (FPs) as low cost, durable, thin engineering elements was evaluated. Specifically, 21 FPs incorporating different contents of lightweight expanded clay (leca) (i.e. 40, 20, and 10 vol%) and perlite (i.e. 55, 35, and 15 vol%) aggregates and different number of expanded rib lath (ERL) layers (i.e. 1, 2 and 3) were constructed and subjected to three-point flexure test. Further, experimental and theoretical results of first crack (F-cr) and ultimate (F-u) loads were compared against each other by means of load deflection curves. A statistical analysis was also performed using Taguchi method to obtain the optimal value and contribution of influential factors. The results indicated that the mean values of F-cr and F-u were higher at the FPs incorporating leca and perlite, respectively. In addition, the values of deflection at first crack (D-Fcr) and ultimate (D-Fu) loads for the FPs incorporating leca were lower than those of FPs incorporating perlite by about 13% and 31%, respectively, leading to a higher ductility index (DI) for the FPs incorporating perlite. Comparing the behavior of lightweight and normal FPs revealed that the DIs of the leca- and perlite-incorporated FPs were about 21% lower and 5% higher than normal FPs, respectively. The results of the statistical analysis showed that the volume content of lightweight aggregates provided higher contribution to improve the F-cr of the FPs, while the number of ERL layers was a more influential factor on improving the F-u and controlling the D-Fcr and D-Fu of the FPs.
引用
收藏
页码:382 / 393
页数:12
相关论文
共 55 条
[1]  
Aboul-Anen Boshra, 2009, International Journal of Recent Trends in Engineering, V1, P25
[2]   Flexural behaviour of reinforced concrete slabs with ferrocement tension zone cover [J].
Al-Kubaisy, MA ;
Jumaat, MZ .
CONSTRUCTION AND BUILDING MATERIALS, 2000, 14 (05) :245-252
[3]   Behavior of pre-cast U-Shaped Composite Beam integrating cold-formed steel with ferro-cement slab [J].
Alhajri, T. M. ;
Tahir, M. M. ;
Azimi, M. ;
Mirza, J. ;
Lawan, M. M. ;
Alenezi, K. K. ;
Ragaee, M. B. .
THIN-WALLED STRUCTURES, 2016, 102 :18-29
[4]  
[Anonymous], 1988, ACI STRUCT J, V85, P325
[5]  
[Anonymous], 2015, CONCR RES LETT
[6]  
[Anonymous], 2004, B103462009 EN
[7]  
[Anonymous], 2005, B1365812005 EN
[8]  
[Anonymous], AIN SHAMS ENG J
[9]  
[Anonymous], ENG SCI TECHNOL INT
[10]  
[Anonymous], 2009, B123903 EN BRIT STAN