Ion-pair-reversed phase liquid chromatography with ultraviolet detection for analysis of ultraviolet transparent cations

被引:3
作者
He, Yan [1 ]
Cook, Kenneth S. [1 ]
Littlepage, Eric [1 ]
Cundy, John [2 ]
Mangalathillam, Ratish [2 ]
Jones, Michael T. [1 ]
机构
[1] Pfizer BioTherapeut R&D Pharmaceut Sci, Analyt R&D, Chesterfield, MO 63017 USA
[2] Pfizer BioTherapeut R&D Pharmaceut Sci, BioProc R&D, Chesterfield, MO 63017 USA
关键词
Ion-pair RPLC; Cations; Improve UV detection; HYDROPHILIC-INTERACTION CHROMATOGRAPHY; LIGHT-SCATTERING DETECTION; QUATERNARY AMMONIUM HERBICIDES; MASS-SPECTROMETRY; HPLC; TECHNOLOGY; EXTRACTION; SEPARATION; PEPTIDES; PROTEINS;
D O I
10.1016/j.chroma.2015.07.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes the use of an anionic ion-pair reagent (IPR) to impove the ultraviolet (UV) detection and hydrophobic retention of polar and UV transparent cations. Anionic IPR added to the mobile phase forms an ion-pair with cations. Formation of the ion-pair causes a redshift in the absorption wavength, making it possible for direct UV detection of UV-inactive cations. The ion-pairs with increased hydrophobicity were separated by reversed phase liquid chromatography (RPLC). Different perfluorinated caboxylic acids (trifluoroacetic acid, heptafluorobutyric acid, nonafluoropentanoic acid) were evaluted as IPR in the separation and detection of the common cations sodium, ammonium and Tris(hydroxymethyl)aminomethane (Tris). The effects of the IPR type and concentration on separation and detection have been investigated to understand the separation and detection mechanisms. The optimal separation and detection condtions were attained with mobile phase containing 0.1% nonafluoropentanoic acid and with the UV detection at 210 nm. UV detection and charged aerosol detection (CAD) were compared in the quantitation of the cations. The limit of quantitation (LOQ) of sodium and Tris with UV detection is comparable to that by CAD. The LOQ of ammonium with UV detection (1 ppm or 3 ng) is about 20-fold lower than that (20 ppm or 60 ng) by CAD. The RPLC-UV method was used to monitor ammonium clearance during ultrafiltration and diafiltration in the manfucaturing of biopharmceutical drug substance. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:261 / 266
页数:6
相关论文
共 29 条
  • [1] Aguilar MI, 1996, METHOD ENZYMOL, V270, P3
  • [2] Brezovska K, 2010, J AOAC INT, V93, P1113
  • [3] Ion-pair liquid chromatography atmospheric pressure ionization mass spectrometry for the determination of quaternary ammonium herbicides
    Castro, R
    Moyano, E
    Galceran, MT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 830 (01) : 145 - 154
  • [4] On-line ion-pair solid-phase extraction-liquid chromatography-mass spectrometry for the analysis of quaternary ammonium herbicides
    Castro, R
    Moyano, E
    Galceran, MT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) : 441 - 449
  • [5] Cecchi T, 2010, ANAL CHEM SER, P1
  • [6] A new method of ion chromatography technology for speedy determination and analysis in organic electrosynthesis of glyoxylic acid
    Chen, SP
    Huang, T
    Sun, SG
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1089 (1-2) : 142 - 147
  • [7] Analysis of volatile bases by high performance liquid chromatography with aerosol-based detection
    Cohen, Ryan D.
    Liu, Yong
    Gong, Xiaoyi
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1229 : 172 - 179
  • [8] REVERSED-PHASE ION-PAIR CHROMATOGRAPHY WITH UV-ABSORBING IONS IN THE MOBILE PHASE
    DENKERT, M
    HACKZELL, L
    SCHILL, G
    SJOGREN, E
    [J]. JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3): : 31 - 43
  • [9] Rapid determination of bisphosphonates by ion chromatography with indirect UV detection
    Fernandes, Christian
    Leite, Rodrigo S.
    Lancas, Fernando M.
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2007, 45 (05) : 236 - 241
  • [10] General theory of indirect detection in chromatography
    Forssen, Patrik
    Fornstedt, Torgny