Determination of sulfite in beer samples using an amperometric fill and flow channel biosensor employing sulfite oxidase

被引:37
|
作者
Zhao, M [1 ]
Hibbert, DB [1 ]
Gooding, JJ [1 ]
机构
[1] Univ New S Wales, Sch Chem, Sydney, NSW 2052, Australia
关键词
sulfite; beer samples; fill and flow channel biosensor; enzymatic analysis;
D O I
10.1016/j.aca.2005.05.083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method is described to determine sulfite in beer samples using a fill and flow channel biosensor. A droplet of sample is placed into the inlet of a rectangular flow cell and begins to flow through the channel by capillarity. The flow is maintained and controlled by a porous outlet plug of defined porosity. In a rectangular flow cell, the sample solution flows through three consecutive zones: over a predictor electrode, an enzyme layer and a detector electrode. Together these three zones enable the differentiation between current due to sulfite and current due to other electroactive species in the sample. The predictor electrode is located upstream, and on the opposite channel wall to the enzyme layer and detector electrode, and is poised at the same potential (+0.65 V versus Ag/AgCl) as the detector electrode. On this electrode, the current contribution from all species in the sample solution that are oxidized at that potential is determined. The enzyme layer contains sulfite oxidase, which, in the process of oxidizing sulfite, produces hydrogen peroxide, which itself is reduced by excess sulfite. The current at the downstream detector electrode is therefore different from that at the predictor electrode as a result of the enzyme reaction and the difference of the currents, corrected for the dimensions of the electrodes, is proportional to the concentration of sulfite. The method enables a straightforward correction of the interfering current at the detector electrode and a determination of the analyte concentration. The effect of interferences from ascorbic acid, ethanol, sorbic acid and tartaric acid in the detection of sulfite is efficiently removed. The concentration of sulfite in a sample of beer measured by the biosensor is equivalent to that measured using a reference method based on the AOAC-recommended Monier-Williams method. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [31] Flow-injection amperometric determination of dopamine in pharmaceuticals using a polyphenol oxidase biosensor obtained from soursop pulp
    Bezerra, VS
    De Lima, JL
    Montenegro, MCBSM
    Araújo, AN
    Da Silva, VL
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) : 1025 - 1031
  • [32] Colorimetric determination of sulfite in "Kanpyo" (dried gourd shavings) and "Konnyaku-seiko" (devil's-tongue fine powder) using sulfite oxidase and catalase
    Aoki, K
    Ueno, S
    Ishizaki, M
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2002, 43 (03): : 165 - 168
  • [33] OXIDATIVE AMPEROMETRIC FLOW-INJECTION DETERMINATION OF SULFITE AT AN ELECTROCHEMICALLY PRE-TREATED GLASSY-CARBON ELECTRODE
    FOGG, AG
    FERNANDEZARCINIEGA, MA
    ALONSO, RM
    ANALYST, 1985, 110 (07) : 851 - 853
  • [34] Simple flow injection for determination of sulfite by amperometric detection using glassy carbon electrode modified with carbon nanotubes-PDDA-gold nanoparticles
    Amatatongchai, Maliwan
    Sroysee, Wongduan
    Chairam, Sanoe
    Nacapricha, Duangjai
    TALANTA, 2015, 133 : 134 - 141
  • [35] Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode
    Alamo, Lori Shayne T.
    Tangkuaram, Tanin
    Satienperakul, Sakchai
    TALANTA, 2010, 81 (4-5) : 1793 - 1799
  • [36] Spectrophotometric determination of total sulfite in white wine samples using crude extracts from flowers
    Soares, MHFB
    Ramos, LA
    Cavalheiro, ÉTG
    JOURNAL OF CHEMICAL EDUCATION, 2002, 79 (09) : 1111 - 1113
  • [37] Fluorometric Determination of Sulfite and Nitrite in Aqueous Samples Using a Novel Detection Unit of a Microfluidic Device
    Shin-ichiro Fujii
    Takahito Tokuyama
    Mitsuru Abo
    Akira Okubo
    Analytical Sciences, 2004, 20 : 209 - 212
  • [38] Simultaneous Determination of Hydroxylamine, Phenol and Sulfite in Water and Waste Water Samples Using A Voltammetric Nanosensor
    Gupta, Vinod Kumar
    Karimi-Maleh, Hassan
    Sadegh, Roya
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (01): : 303 - 316
  • [39] Flow-injection chemiluminescence determination of papaverine using cerium(IV)-sulfite system
    Zhang, S
    Zhuang, YF
    Ju, HX
    ANALYTICAL LETTERS, 2004, 37 (01) : 143 - 155
  • [40] ELIMINATION OF DOUBLE PEAKS IN THE IODIMETRIC FLOW-INJECTION VISIBLE SPECTROPHOTOMETRIC DETERMINATION OF SULFITE USING A SINGLE-CHANNEL MANIFOLD
    FOGG, AG
    WANG, XW
    TYSON, JF
    ANALYST, 1990, 115 (03) : 305 - 307