Sutureless aortic valve replacement in patients who have bicuspid aortic valve

被引:35
|
作者
Nguyen, Anthony [1 ,2 ]
Fortin, William [2 ]
Mazine, Amine [2 ]
Bouchard, Denis [1 ,2 ]
Carrier, Michel [1 ,2 ]
El Hamamsy, Ismail [1 ,2 ]
Lamarche, Yoan [1 ,2 ]
Demers, Philippe [1 ,2 ]
机构
[1] Montreal Heart Inst, Dept Cardiac Surg, Montreal, PQ H1T 1C8, Canada
[2] Univ Montreal, Montreal, PQ, Canada
关键词
aortic valve; replacement; bicuspid aortic valve; bioprosthesis; Perceval S; IMPLANTATION; STENOSIS; REGURGITATION; BIOPROSTHESIS; MULTICENTER; FREQUENCY; DISEASE; SURGERY; ADULTS; STENT;
D O I
10.1016/j.jtcvs.2015.05.071
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Bicuspid aortic valve (BAV) is generally considered to be a contraindication to sutureless aortic valve replacement (AVR). The aim of this study was to evaluate the feasibility and perioperative outcomes of this technique in patients with BAV. Methods: From June 2011 to January 2014, a total of 25 patients who underwent sutureless AVR had documented BAV. Thirteen patients (52%) had median sternotomy, and 12 patients (48%) a minimally invasive approach. Results: The study population included 17 (68%) men with a median age of 77.8 +/- 5.4 years. The mean EuroSCORE II was 3.4% +/- 2.6%. Concomitant procedures included coronary artery bypass grafting in 8 patients (32%), 2 AVRs (8%), 1 mitral valve repair (4%), 1 septal myomectomy (4%), and 1 atrial septal defect closure (4%). The mean transaortic valve gradient decreased from 49.4 +/- 15.7, to 14.5 +/- 5.4 mm Hg postoperatively. The mean aortic valve area increased from 0.78 +/- 0.18, to 1.75 +/- 0.43 cm(2) postoperatively. Five patients (20%) suffered from atrioventricular block that required permanent pacemaker implantation. Two patients (8%) suffered a stroke. No major paravalvular leakage occurred, and no postoperative valve migration. In-hospital mortality occurred in 1 patient (4%). The mean intensive care unit length of stay was 3 +/- 2 days postoperatively. Conclusions: This study demonstrates that a sutureless aortic valve can be deployed in patients with BAV without increasing the risk of paravalvular leakage. BAV should not be considered a contraindication to sutureless AVR.
引用
收藏
页码:851 / 857
页数:7
相关论文
共 50 条
  • [41] Sutureless Valve in Bicuspid Aortic Stenosis: Modified Technique and Midterm Outcome
    Li, Han-Yan
    Tsai, Feng-Chun
    Lu, Cheng-Hui
    Chou, An-Hsun
    Huang, Huei-Chiun
    Gersak, Borut
    THORACIC AND CARDIOVASCULAR SURGEON, 2023, 71 (07) : 535 - 541
  • [42] Transcatheter Aortic Valve Replacement for Bicuspid Aortic Valve Stenosis A Practical Operative Overview
    Tarantini, Giuseppe
    Fabris, Tommaso
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (07) : E009827
  • [43] Mitral Valve Repair Versus Replacement in Patients Undergoing Concomitant Aortic Valve Replacement
    Zhang, Yi
    Fu, Guangguo
    Li, Gang
    Jian, Bohao
    Wang, Rui
    Huang, Yang
    Chu, Tongxin
    Wu, Zhongkai
    Zhou, Zhuoming
    Liang, Mengya
    HEART LUNG AND CIRCULATION, 2025, 34 (01) : 3 - 15
  • [44] Bicuspid Valve Sizing for Transcatheter Aortic Valve Implantation: The Missing Link
    Costa, Giulia
    Angelillis, Marco
    Petronio, Anna Sonia
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 8
  • [45] Research Progress of Transcatheter Aortic Valve Replacement in Aortic Valve Stenosis due to Bicuspid Aortic Valve
    Chen, Liyan
    Jiang, Li
    Zou, Mei
    Chen, Xuanlan
    Wu, Zhiyong
    HEART SURGERY FORUM, 2024, 27 (04) : E431 - E438
  • [46] Comparison of the results of transcatheter aortic valve implantation in patients with bicuspid and tricuspid aortic valve
    Chodor, Piotr A.
    Wilczek, Krzysztof
    Chodor-Rozwadowska, Karolina
    Przybylski, Roman
    Glowacki, Jan
    Niklewski, Tomasz
    Wloch, Lukasz
    Gasior, Mariusz
    Zembala, Marian
    Kalarus, Zbigniew
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2021, 17 (01): : 82 - 92
  • [47] Outcomes After Isolated Aortic Valve Replacement in Patients with Bicuspid vs Tricuspid Aortic Valve
    Sun, Jing
    Chen, Sipeng
    Sun, Cheng
    Qi, Hongxia
    Qian, Xiangyang
    Zheng, Zhe
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2022, 34 (03) : 854 - 865
  • [48] Permanent pacemaker implantation after transcatheter aortic valve replacement in bicuspid aortic valve patients
    Xiong, Tian-Yuan
    Liao, Yan-Biao
    Li, Yi-Jian
    Zhao, Zhen-Gang
    Wei, Xin
    Tsauo, Jiay-yu
    Xu, Yuan-Ning
    Feng, Yuan
    Chen, Mao
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2018, 31 (06) : 878 - 884
  • [49] Lipoprotein(a) As a Potential Predictive Factor for Earlier Aortic Valve Replacement in Patients with Bicuspid Aortic Valve
    Krzesinska, Aleksandra
    Nowak, Maria
    Mickiewicz, Agnieszka
    Chyla-Danil, Gabriela
    Cwiklinska, Agnieszka
    Koper-Lenkiewicz, Olga M.
    Kaminska, Joanna
    Matowicka-Karna, Joanna
    Gruchala, Marcin
    Jankowski, Maciej
    Fijalkowski, Marcin
    Kuchta, Agnieszka
    BIOMEDICINES, 2023, 11 (07)
  • [50] Differences in baseline characteristics and outcomes of bicuspid and tricuspid aortic valves in surgical aortic valve replacement
    Celik, Mevlut
    Milojevic, Milan
    Durko, Andras P.
    Oei, Frans B. S.
    Bogers, Ad J. J. C.
    Mahtab, Edris A. F.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2021, 59 (06) : 1191 - 1199