Quantitative Evaluation of Cerebral Blood Flow and Oxygen Metabolism in Normal Anesthetized Rats: 15O-Labeled Gas Inhalation PET with MRI Fusion

被引:20
|
作者
Watabe, Tadashi [1 ,2 ]
Shimosegawa, Eku [1 ]
Watabe, Hiroshi [3 ]
Kanai, Yasukazu [3 ]
Hanaoka, Kohei [1 ]
Ueguchi, Takashi [4 ]
Isohashi, Kayako [1 ]
Kato, Hiroki [1 ]
Tatsumi, Mitsuaki [4 ]
Hatazawa, Jun [1 ,2 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Nucl Med & Tracer Kinet, Suita, Osaka, Japan
[2] Osaka Univ, Immunol Frontier Res Ctr, Suita, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Mol Imaging Med, Suita, Osaka, Japan
[4] Osaka Univ Hosp, Dept Radiol, Suita, Osaka, Japan
关键词
O-15-gas PET; CBF; OEF; CMRO2; POSITRON-EMISSION-TOMOGRAPHY; BRAIN; O-15; EXTRACTION; CONSUMPTION; VALIDATION; ISCHEMIA; STROKE; VOLUME; MODEL;
D O I
10.2967/jnumed.112.109751
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET with O-15 gas has been used for the quantitative measurement of cerebral blood flow (CBF), cerebral metabolic rate of oxygen (CMRO2), oxygen extraction fraction (OEF), and cerebral blood volume (CBV) in humans. However, several technical difficulties limit its use in experiments on small animals. Herein, we describe the application of the O-15 gas steady-state inhalation method for normal anesthetized rats. Methods: Eight normal male Sprague-Dawley rats (mean body weight +/- SD, 268 +/- 14 g) under anesthesia were investigated by O-15-labeled gas PET. After tracheotomy, an airway tube was placed in the trachea, and the animals were connected to a ventilator (tidal volume, 3 cm(3); frequency, 60/min). The CBF and OEF were measured according to the original steady-state inhalation technique under artificial ventilation with O-15-CO2 and O-15-O-2 gases delivered through the radioactive gas stabilizer. CBV was measured by O-15-CO gas inhalation and corrected for the intravascular hemoglobinbound O-15-O-2. Arterial blood sampling was performed during each study to measure the radioactivity of the whole blood and plasma. MR image was performed with the same acrylic animal holder immediately after the PET. Regions of interest were placed on the whole brain of the PET images with reference to the semiautomatically coregistered PET/MR fused images. Results: The data acquisition time for the whole PET experiment in each rat was 73.3 +/- 5.8 (range, 68-85) min. In both the O-15-CO2 and the O-15-O-2 studies, the radioactivity count of the brain reached a steady state by approximately 10 min after the start of continuous inhalation of the gas. The quantitative PET data of the whole brain were as follows: CBF, 32.3 +/- 4.5 mL/100 mL/min; CMRO2, 3.23 +/- 0.42 mL/100 mL/min; OEF, 64.6% +/- 9.1%; and CBV, 5.05 +/- 0.45 mL/100 mL. Conclusion: Although further technical improvements may be needed, this study demonstrated the feasibility of quantitative PET measurement of CBF, OEF, and CMRO2 using the original steady-state inhalation method of O-15-CO2 and O-15-O-2 gases and measurement of CBV using the O-15-CO gas inhalation method in the brain of normal anesthetized rats.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 33 条
  • [31] Evaluation of drug effects on cerebral blood flow and glucose uptake in un-anesthetized and un-stimulated rats: application of free-moving apparatus enabling to keep rats free during PET/SPECT tracer injection and uptake
    Sugita, Taku
    Kondo, Yusuke
    Ishino, Seigo
    Mori, Ikuo
    Horiguchi, Takashi
    Ogawa, Mikako
    Magata, Yasuhiro
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (08) : 753 - 760
  • [32] Database of normal human cerebral blood flow measured by SPECT: I. Comparison between I-123-IMP, Tc-99m-HMPAO, and Tc-99m-ECD as referred with O-15 labeled water PET and voxel-based morphometry
    Ito H.
    Inoue K.
    Goto R.
    Kinomura S.
    Taki Y.
    Okada K.
    Sato K.
    Sato T.
    Kanno I.
    Fukuda H.
    Annals of Nuclear Medicine, 2006, 20 (2) : 131 - 138
  • [33] Database of normal human cerebral blood flow measured by SPECT: I. Comparison between I-123-IMP, Tc-99m-HMPAO, and Tc-99m-ECD as referred with O-15 labeled water PET and voxel-based morphometry
    Ito, H
    Inoue, K
    Goto, R
    Kinomura, S
    Taki, Y
    Okada, K
    Sato, K
    Sato, T
    Kanno, I
    Fukuda, H
    ANNALS OF NUCLEAR MEDICINE, 2006, 20 (02) : 131 - 138